Intramedullary nail and volar plate offer similar outcome in displaced, unstable DRFs
Intramedullary nail and volar plate offer similar outcome in displaced, unstable DRFs
Randomized comparison of volar locking plates and intramedullary nails for unstable distal radius fractures
J Hand Surg Am. 2015 Jun;40(6):1095-101Did you know you're eligible to earn 0.5 CME credits for reading this report? Click Here
Synopsis
60 patients with a closed, displaced, unstable extra-articular distal radius fracture (AO type A) requiring fixation were randomized to be treated with either an intramedullary nail (IMN) or a volar locking plate (VLP). The purpose of this study was compare functional and radiographical results between the two treatment options over 2 years postoperatively. The IMN demonstrated significantly great...
To view the full content, login to your account,
or start your 30-day FREE Trial today.
FREE TRIAL
LOGIN
Forgot Password?
Explore some of our unlocked ACE Reports below!
Learn about our AI Driven
High Impact Search Feature
Our AI driven High Impact metric calculates the impact an article will have by considering both the publishing journal and the content of the article itself. Built using the latest advances in natural language processing, OE High Impact predicts an article’s future number of citations better than impact factor alone.
Continue
Join the Conversation
Please Login or Join to leave comments.