April 2015

Highly porous metal tibia comparable to traditional modular cemented tibia in TKA

Vol: 4| Issue: 4| Number:61| ISSN#: 2564-2537
Study Type:Therapy
OE Level Evidence:2
Journal Level of Evidence:1

The Mark Coventry Award: Trabecular metal tibial components were durable and reliable in primary total knee arthroplasty: a randomized clinical trial.

Clin Orthop Relat Res. 2015 Jan;473(1):34-42.

Contributing Authors:
L Pulido MP Abdel DG Lewallen MJ Stuart J Sanchez-Sotelo AD Hanssen MW Pagnano

Did you know you're eligible to earn 0.5 CME credits for reading this report? Click Here

Synopsis

347 patients were involved in this study comparing highly porous metal to the standard modular cemented tibial components in total knee arthroplasty over a period of 2 to 9 years (average 5 years). This was done through randomization into 3 groups, receiving traditional modular cemented tibial components, cemented highly porous metal tibial components, or uncemented highly porous metal tibial comp...

CME Image

Did you know that you’re eligible to earn 0.5 CME credits for reading this report!

LEARN MORE

Join the Conversation

Please Login or Join to leave comments.

Learn about our AI Driven
High Impact Search Feature

High Impact Icon

Our AI driven High Impact metric calculates the impact an article will have by considering both the publishing journal and the content of the article itself. Built using the latest advances in natural language processing, OE High Impact predicts an article’s future number of citations better than impact factor alone.

Continue