Percutaneous Compression Plate versus Parallel Screws for Femoral Neck Fractures

Share
Reprints
Cite This
About
+ Favorites
Share
Reprints
Cite This
About
+ Favorites
Ace Report Cover
March 2024

Percutaneous Compression Plate versus Parallel Screws for Femoral Neck Fractures

Vol: 306| Issue: 3| Number:15| ISSN#: 2564-2537
Study Type:Therapy
OE Level Evidence:1
Journal Level of Evidence:1

Comparison of percutaneous compression plate to parallel screws in the treatment of nondisplaced femoral neck fractures in elderly patients: a prospective, randomized study.

Arch Orthop Trauma Surg . 2023 Dec;143(12):7063-7071.

Contributing Authors:
T Wang H Yin X Zhao C Ma

Did you know you're eligible to earn 0.5 CME credits for reading this report? Click Here

Synopsis

Two hundred eighteen patients with non-displaced femoral neck fractures in elderly individuals were randomized to receive internal fixation using either percutaneous compression plate (PCCP; n=97 analyzed) or parallel screws (PS; n=97 analyzed). The primary outcome of interest was the time to full weight-bearing, with secondary outcomes including operative time, intraoperative blood loss, hemoglob...

CME Image

Did you know that you’re eligible to earn 0.5 CME credits for reading this report!

LEARN MORE

Join the Conversation

Please Login or Join to leave comments.

Learn about our AI Driven
High Impact Search Feature

High Impact Icon

Our AI driven High Impact metric calculates the impact an article will have by considering both the publishing journal and the content of the article itself. Built using the latest advances in natural language processing, OE High Impact predicts an article’s future number of citations better than impact factor alone.

Continue