Vol:3 Issue:6 Number:68 ISSN#:2564-2537
DOWNLOAD ESPAÑOL
RCT
ACE Report #6531
Ace Report Cover Arthroplasty

EFORT: THA: HXLPE vs. UHMWPE liners in combination with Ox or CoCr femoral heads


How to Cite

OrthoEvidence. EFORT: THA: HXLPE vs. UHMWPE liners in combination with Ox or CoCr femoral heads . ACE Report. 2014;3(6):68. Available from: https://myorthoevidence.com/AceReport/Report/6531

Study Type:Randomized Trial
OE Level Evidence:N/A
Journal Level of Evidence:N/A

A Randomized Controlled Trial Comparing Wear Of Oxidized Zirconium And Cobalt-Chrome On Standard And Cross-Linked Polyethylene

Contributing Authors: Z Morison S Patil H Khan ER Bogoch EH Schemitsch JP Waddell

Did you know you're eligible to earn 0.5 CME credits for reading this report? Click Here

CONFERENCE ACE REPORTS

This ACE Report is a summary of a conference presentation or abstract. The information provided has limited the ability to provide an accurate assessment of the risk of bias or the overall quality. Please interpret the results with caution as trials may be in progress and select results may have been presented.

Synopsis

80 patients (91 hips) were randomized to evaluate the clinical and radiographic outcomes associated with conventional (UHMWPE) or crosslinked (HXLPE) polyethylene liners, paired with either oxidized zirconiu (oxinium; Ox) or cobalt-chromium (Co-Cr) femoral heads. Patients received either CoCr/HXLPE; Ox/HXLPE; CoCr/UHMWPE; or Ox/UHMWPE. Patients are currently being monitored up to 10 years postoper...