To unlock this feature and to subscribe to our weekly evidence emails, please create a FREE orthoEvidence account.

SIGNUP

Already Have an Account?

Loading...
Visit our Evidence-Based Covid-19 Website and Stay Up to Date with the latest Research.
Ace Report Cover

Systemic cobalt release after metal-on-metal total hip arthroplasty: 5 year follow-up

Download
Share
Reprints
Cite This
About
+ Favorites
Share
Reprints
Cite This
About
+ Favorites
Ace Report Cover
September 2014

Systemic cobalt release after metal-on-metal total hip arthroplasty: 5 year follow-up

Vol: 3| Issue: 9| Number:58| ISSN#: 2564-2537
Study Type:Therapy
OE Level Evidence:2
Journal Level of Evidence:N/A

Serum cobalt levels after metal-on-metal total hip arthroplasty

J Bone Joint Surg Am. 2003 Nov;85-A(11):2168-73

Contributing Authors:
W Brodner P Bitzan V Meisinger A Kaider F Gottsauner-Wolf R Kotz

Did you know you're eligible to earn 0.5 CME credits for reading this report? Click Here

Synopsis

100 patients undergoing a total hip arthroplasty without cement for unilateral osteoarthritis or unilateral osteonecrosis were randomized to be treated with a metal-on-metal articulation or with a ceramic-on-polyethylene bearing. Blood samples were taken multiple times over a 5 year period and serum cobalt concentrations measured. In the metal articulation group, median cobalt levels were 1 μg/L a...

CME Image

Did you know that you’re eligible to earn 0.5 CME credits for reading this report!

LEARN MORE

Join the Conversation

Please Login or Join to leave comments.

Learn about our AI Driven
High Impact Search Feature

High Impact Icon

Our AI driven High Impact metric calculates the impact an article will have by considering both the publishing journal and the content of the article itself. Built using the latest advances in natural language processing, OE High Impact predicts an article’s future number of citations better than impact factor alone.

Continue