ACE Report Cover
Function and radiographic outcome of carbon peek and titanium locking plates similar for DRF
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
HAND & WRIST
Function and radiographic outcome of carbon peek and titanium locking plates similar for DRF .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2018;6(10):3 Injury. 2017 Oct;48 Suppl 3:S24-S29
Autori che hanno contribuito

D Perugia C Iorio A Ferretti D Mazza C Civitenga M Guzzini

30 patients undergoing volar plate fixation for an AO type B or C displaced fracture of the distal radius were included in this study to compare two different plates. Patients were randomized to undergo the procedure using either Carbon-Peek volar locking plates or titanium volar locking plates. Follow-up was conducted over a 12-month period and patients were evaluated for forearm range of motion, hand grip strength, key pinch strength, the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and a visual analog scale. Dorso-palmar and lateral x-rays were also used to assess radiographic parameters. The results of this study at 12 months indicated no significant differences in functional outcome or radiographic outcome between the two plates.


Dettagli sul finanziamento della pubblicazione +
Finanziamento:
Not Reported
Conflicts:
None disclosed

Rischio di pregiudizio

7/10

Criteri di segnalazione

16/21

Indice di fragilità

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sì = 1

Incerto = 0,5

Non rilevante = 0

No = 0

La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.

3/4

Randomization

2/4

Outcome Measurements

3/4

Inclusion / Exclusion

4/4

Therapy Description

4/5

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.

Perché questo studio era necessario ora?

The distal radius is one of the most common bones to be fractured, particularly among older adults. Volar plating is a widely used method of fixation for these injuries. Most plates are constructed of a titanium alloy, but more recently, a plate composed of carbon fiber reinforced polyetheretherketone (CFR-PEEK) has been introduced.

Qual era la domanda di ricerca principale?

In volar plate fixation of a distal radius fracture, is there any significant difference in functional outcome or radiographic outcome between cases completed using a carbon fiber reinforced polyetheretherketone and cases completed using a titanium plate, assessed over a minimum of 12-month follow-up

Caratteristiche dello studio +
Population:
30 patients undergoing volar plate fixation for an AO type B or C displaced fracture of the distal radius. Cases of open fracture, bilateral fractures, or concurrent major trauma were excluded.
Intervention:
CFR-PEEK group: Fixation was performed with the use of a carbon fiber reinforced polyetheretherketone plate (CarboFix; CarboFix Orthopedics Ltd.) (n=15; Mean age: 56.8)
Comparison:
Titanium group: Fixation was performed with the use of a titanium plate (Acu-Lock Volar Distal Radius Plate; Acumed Ltd.) (n=15; Mean age: 52.6)
Outcomes:
Clinical examination included assessment of wrist and forearm range of motion, hand grip strength and key pinch strength. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and a visual analog scale were also used to assess patients. Dorso-palmar and lateral x-rays were used to assess radiographic parameters, including radial height, radial inclination, volar tilt, ulnar variance, and articular step-off.
Methods:
RCT
Time:
Follow-up was scheduled for 1, 3, 6, and 12 months postoperatively.
Quali erano i risultati importanti?
  • Mean DASH at final follow-up did not significantly differ between the CFR-PEEK group (15.3) and the titanium group (12.2) (p>0.05).
  • Mean VAS score at final follow-up did not significantly differ between the CFR-PEEK group (3.6) and the titanium group (2.9) (p>0.05).
  • Mean range of motion at final follow-up did not significantly differ between the CFR-PEEK group and the titanium group (p>0.05).
  • No significant differences in radiographic parameters were recorded between groups at final follow-up.
  • No complications were recorded in either group.
Che cosa devo ricordare di più?

In volar plating of a displaced distal radius fracture, no significant differences in functional outcome or radiographic outcome were noted between plates composed of carbon fiber reinforced polyetheretherketone and titanium plates after a minimum of 1 year.

Come influenzerà l'assistenza ai miei pazienti?

The results of this study suggest that similar outcomes are achieved by the CFR-PEEK volar plate to that of the more standard titanium plate for fixation of displaced distal radius fractures.

DISCLAIMER

Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.

0 di 4 articoli mensili GRATUITI sbloccati
Ha raggiunto il suo limite di 4 visualizzazioni di articoli gratuiti questo mese

Accesso a OrthoEvidence a soli 1,99 dollari a settimana.

Rimanga in contatto con le ultime prove. Può disdire in qualsiasi momento.
  • Valutazioni critiche dei più recenti studi randomizzati controllati ad alto impatto e delle revisioni sistematiche in ortopedia.
  • Accesso ai contenuti del podcast OrthoEvidence, tra cui collaborazioni con il Journal of Bone and Joint Surgery, interviste con chirurghi di fama internazionale e tavole rotonde su notizie e argomenti ortopedici.
  • Abbonamento a The Pulse, una newsletter bisettimanale basata sulle evidenze scientifiche, progettata per aiutarla a prendere decisioni cliniche migliori.
Upgrade
Bentornato!
Ha dimenticato la password?
Inizi la sua prova gratuita oggi stesso!

Il suo account sarà affiliato a
e includerà l'accesso gratuito a OrthoEvidence


O
Ha dimenticato la password?

O
Controlli la sua e-mail

Se esiste un account con l'indirizzo e-mail fornito, le verrà inviata un'e-mail di reimpostazione della password. Se non vede l'e-mail, controlli la cartella spam o posta indesiderata.

Per ulteriore assistenza, contatti il nostro team di supporto.

Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Tradurre il Rapporto ACE

OrthoEvidence utilizza un servizio di traduzione di terze parti per rendere i contenuti accessibili in più lingue. Si prega di notare che, sebbene venga fatto ogni sforzo per garantire l'accuratezza, le traduzioni potrebbero non essere sempre perfette.

Come citare questo documento ACE Report

OrthoEvidence. Function and radiographic outcome of carbon peek and titanium locking plates similar for DRF. OE Journal. 2018;6(10):3. Available from: https://myorthoevidence.com/AceReport/Show/function-and-radiographic-outcome-of-carbon-peek-and-titanium-locking-plates-similar-for-drf

Copiare la citazione
Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Funzionalità per i membri Premium

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence Premium.

Condividi questo articolo ACE Report