HAND & WRIST
Function and radiographic outcome of carbon peek and titanium locking plates similar for DRF .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2018;6(10):3 Injury. 2017 Oct;48 Suppl 3:S24-S29

30 patients undergoing volar plate fixation for an AO type B or C displaced fracture of the distal radius were included in this study to compare two different plates. Patients were randomized to undergo the procedure using either Carbon-Peek volar locking plates or titanium volar locking plates. Follow-up was conducted over a 12-month period and patients were evaluated for forearm range of motion, hand grip strength, key pinch strength, the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and a visual analog scale. Dorso-palmar and lateral x-rays were also used to assess radiographic parameters. The results of this study at 12 months indicated no significant differences in functional outcome or radiographic outcome between the two plates.


Publication Funding Details +
Funding:
Not Reported
Conflicts:
None disclosed

Risk of Bias

7/10

Reporting Criteria

16/21

Fragility Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Yes = 1

Uncertain = 0.5

Not Relevant = 0

No = 0

The Reporting Criteria Assessment evaluates the transparency with which authors report the methodological and trial characteristics of the trial within the publication. The assessment is divided into five categories which are presented below.

3/4

Randomization

2/4

Outcome Measurements

3/4

Inclusion / Exclusion

4/4

Therapy Description

4/5

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

The Fragility Index is a tool that aids in the interpretation of significant findings, providing a measure of strength for a result. The Fragility Index represents the number of consecutive events that need to be added to a dichotomous outcome to make the finding no longer significant. A small number represents a weaker finding and a large number represents a stronger finding.

Why was this study needed now?

The distal radius is one of the most common bones to be fractured, particularly among older adults. Volar plating is a widely used method of fixation for these injuries. Most plates are constructed of a titanium alloy, but more recently, a plate composed of carbon fiber reinforced polyetheretherketone (CFR-PEEK) has been introduced.

What was the principal research question?

In volar plate fixation of a distal radius fracture, is there any significant difference in functional outcome or radiographic outcome between cases completed using a carbon fiber reinforced polyetheretherketone and cases completed using a titanium plate, assessed over a minimum of 12-month follow-up

Study Characteristics +
Population:
30 patients undergoing volar plate fixation for an AO type B or C displaced fracture of the distal radius. Cases of open fracture, bilateral fractures, or concurrent major trauma were excluded.
Intervention:
CFR-PEEK group: Fixation was performed with the use of a carbon fiber reinforced polyetheretherketone plate (CarboFix; CarboFix Orthopedics Ltd.) (n=15; Mean age: 56.8)
Comparison:
Titanium group: Fixation was performed with the use of a titanium plate (Acu-Lock Volar Distal Radius Plate; Acumed Ltd.) (n=15; Mean age: 52.6)
Outcomes:
Clinical examination included assessment of wrist and forearm range of motion, hand grip strength and key pinch strength. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and a visual analog scale were also used to assess patients. Dorso-palmar and lateral x-rays were used to assess radiographic parameters, including radial height, radial inclination, volar tilt, ulnar variance, and articular step-off.
Methods:
RCT
Time:
Follow-up was scheduled for 1, 3, 6, and 12 months postoperatively.
What were the important findings?
  • Mean DASH at final follow-up did not significantly differ between the CFR-PEEK group (15.3) and the titanium group (12.2) (p>0.05).
  • Mean VAS score at final follow-up did not significantly differ between the CFR-PEEK group (3.6) and the titanium group (2.9) (p>0.05).
  • Mean range of motion at final follow-up did not significantly differ between the CFR-PEEK group and the titanium group (p>0.05).
  • No significant differences in radiographic parameters were recorded between groups at final follow-up.
  • No complications were recorded in either group.
What should I remember most?

In volar plating of a displaced distal radius fracture, no significant differences in functional outcome or radiographic outcome were noted between plates composed of carbon fiber reinforced polyetheretherketone and titanium plates after a minimum of 1 year.

How will this affect the care of my patients?

The results of this study suggest that similar outcomes are achieved by the CFR-PEEK volar plate to that of the more standard titanium plate for fixation of displaced distal radius fractures.

DISCLAIMER

This content found on this page is for informational purposes only and is not intended to be a substitute for professional medical advice, diagnosis, or treatment. If you require medical treatment, always seek the advice of your physician or go to your nearest emergency department. The opinions, beliefs, and viewpoints expressed by the individuals on the content found on this page do not reflect the opinions, beliefs, and viewpoints of OrthoEvidence.

0 of 4 monthly FREE articles unlocked
You've reached your limit of 4 free articles views this month

Access to OrthoEvidence for as little as $1.99 per week.

Stay connected with latest evidence. Cancel at any time.
  • Critical appraisals of the latest, high-impact randomized controlled trials and systematic reviews in orthopaedics
  • Access to OrthoEvidence podcast content, including collaborations with the Journal of Bone and Joint Surgery, interviews with internationally recognized surgeons, and roundtable discussions on orthopaedic news and topics
  • Subscription to The Pulse, a twice-weekly evidence-based newsletter designed to help you make better clinical decisions
Upgrade
Welcome Back!
Forgot Password?
Start your FREE trial today!

Your account will be affiliated with
and includes free access to OrthoEvidence


OR
Forgot Password?

OR
Please check your email

If an account exists with the provided email address, a password reset email will be sent to you. If you don't see an email, please check your spam or junk folder.

For further assistance, contact our support team.

Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Translate ACE Report

OrthoEvidence utilizes a third-party translation service to make content accessible in multiple languages. Please note that while every effort is made to ensure accuracy, translations may not always be perfect.

How to cite this ACE Report

OrthoEvidence. Function and radiographic outcome of carbon peek and titanium locking plates similar for DRF. OE Journal. 2018;6(10):3. Available from: https://myorthoevidence.com/AceReport/Show/function-and-radiographic-outcome-of-carbon-peek-and-titanium-locking-plates-similar-for-drf

Copy Citation
Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Premium Member Feature

To access this feature, you must be logged into a premium OrthoEvidence account.

Share this ACE Report