ACE Report Cover
Electrochemical versus plasma-coated femoral implant in total hip arthroplasty
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
ARTHROPLASTY
Electrochemical versus plasma-coated femoral implant in total hip arthroplasty .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(12):47 Acta Orthop. 2011 Feb;82(1):13-9
Autori che hanno contribuito

BG Boe SM Rohrl T Heier F Snorrason L Nordsletten

50 patients undergoing total hip arthroplasty were randomized to receive either plasma-sprayed hydroxyapatite (HA) or electrochemically deposited hydroxyapatite (Bonemaster, BM),as a coating for the fixation of uncemented femoral stems, in order to compare the safety and efficacy of the two coatings. At a follow-up of two years, the two groups were similar in regards to their clinical outcomes.


Dettagli sul finanziamento della pubblicazione +
Finanziamento:
Industry funded
Sponsor:
Biomet Europe
Conflitti:
None disclosed

Rischio di pregiudizio

6/10

Criteri di segnalazione

17/20

Indice di fragilità

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sì = 1

Incerto = 0,5

Non rilevante = 0

No = 0

La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.

2/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.

Perché questo studio era necessario ora?

Alternative bone coatings, such as Bonemaster (BM), provide potential advantages in terms of remodelling and transporting of bone-active substances. The trial was necessary to investigate whether the use of this alternative is safe for conventional clinical use.

Qual era la domanda di ricerca principale?

In patients undergoing total hip arthroplasty for non-inflammatory osteoarthritis, does electrochemically deposited Bonemaster provide non-inferior results in terms of safety, as compared with a conventional femoral implant utilizing plasma-sprayed hydroxyapatite?

Caratteristiche dello studio +
Population:
50 patients (55 hips) with non-inflammatory osteoarthritis (end-stage) of the hip
Intervention:
Intervention group received a 28-mm cobalt-chrome modular head coated with Bonemaster using electrochemical deposition (n=31)
Comparison:
Control group received a conventional 28-mm cobalt-chrome modular head with plasma-sprayed hydroxyapatite (n=24)
Outcomes:
Bone mineral density (BMD), Femoral stem migration (RSA), Harris Hip Score, Oxford Hip Score
Methods:
RCT; Multicenter
Time:
2 years post-operative
Quali erano i risultati importanti?
  • The null hypothesis was rejected for BMD in Gruen zone 1 (p = .01); bone loss was less in the BM group. The null hypothesis was accepted for all other regions (p > .05)
  • No statistically significant results were obtained with respect to femoral migration or rotation following implantation (p > .05)
  • There were no significant differences in the Harris Hip Scores at two year follow-up between the groups (p > .05)
  • There were no significant differences in the oxford hip score between the two groups (p > .05)
Che cosa devo ricordare di più?

Functional scores, migration, and rotation of the femoral head following total hip arthroplasty were not significantly different. Potential benefits in terms of bone mineral density were identified in favor of the Bonemaster group.

Come influenzerà l'assistenza ai miei pazienti?

The results suggest that Bonemaster is clinically non-inferior to conventional plasma-sprayed hydroxyapatite and is a viable alternative. Long term follow-up is necessary to investigate other potential benefits of electrochemical deposition and whether or not long-term fixation is achieved. The small sample size of the study should be taken into account.

DISCLAIMER

Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.

0 di 4 articoli mensili GRATUITI sbloccati
Ha raggiunto il suo limite di 4 visualizzazioni di articoli gratuiti questo mese

Accesso a OrthoEvidence a soli 1,99 dollari a settimana.

Rimanga in contatto con le ultime prove. Può disdire in qualsiasi momento.
  • Valutazioni critiche dei più recenti studi randomizzati controllati ad alto impatto e delle revisioni sistematiche in ortopedia.
  • Accesso ai contenuti del podcast OrthoEvidence, tra cui collaborazioni con il Journal of Bone and Joint Surgery, interviste con chirurghi di fama internazionale e tavole rotonde su notizie e argomenti ortopedici.
  • Abbonamento a The Pulse, una newsletter bisettimanale basata sulle evidenze scientifiche, progettata per aiutarla a prendere decisioni cliniche migliori.
Upgrade
Close Dialog
Bentornato!
Ha dimenticato la password?
Inizi la sua prova gratuita oggi stesso!

Il suo account sarà affiliato a
e includerà l'accesso gratuito a OrthoEvidence


O
Ha dimenticato la password?

O
Controlli la sua e-mail

Se esiste un account con l'indirizzo e-mail fornito, le verrà inviata un'e-mail di reimpostazione della password. Se non vede l'e-mail, controlli la cartella spam o posta indesiderata.

Per ulteriore assistenza, contatti il nostro team di supporto.

Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Tradurre il Rapporto ACE

OrthoEvidence utilizza un servizio di traduzione di terze parti per rendere i contenuti accessibili in più lingue. Si prega di notare che, sebbene venga fatto ogni sforzo per garantire l'accuratezza, le traduzioni potrebbero non essere sempre perfette.

Come citare questo documento ACE Report

OrthoEvidence. Electrochemical versus plasma-coated femoral implant in total hip arthroplasty. OE Journal. 2013;1(12):47. Available from: https://myorthoevidence.com/AceReport/Show/electrochemical-versus-plasma-coated-femoral-implant-in-total-hip-arthroplasty

Copiare la citazione
Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Funzionalità per i membri Premium

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence Premium.

Condividi questo articolo ACE Report