ARTHROPLASTY
Electrochemical versus plasma-coated femoral implant in total hip arthroplasty .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(12):47 Acta Orthop. 2011 Feb;82(1):13-9
المؤلفون المساهمون

BG Boe SM Rohrl T Heier F Snorrason L Nordsletten

50 patients undergoing total hip arthroplasty were randomized to receive either plasma-sprayed hydroxyapatite (HA) or electrochemically deposited hydroxyapatite (Bonemaster, BM),as a coating for the fixation of uncemented femoral stems, in order to compare the safety and efficacy of the two coatings. At a follow-up of two years, the two groups were similar in regards to their clinical outcomes.


تفاصيل تمويل المنشور +
التمويل:
Industry funded
الراعي:
Biomet Europe
التعارضات:
None disclosed

مخاطر التحيز

6/10

معايير الإبلاغ

17/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

2/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Alternative bone coatings, such as Bonemaster (BM), provide potential advantages in terms of remodelling and transporting of bone-active substances. The trial was necessary to investigate whether the use of this alternative is safe for conventional clinical use.

ما هو سؤال البحث الرئيسي؟

In patients undergoing total hip arthroplasty for non-inflammatory osteoarthritis, does electrochemically deposited Bonemaster provide non-inferior results in terms of safety, as compared with a conventional femoral implant utilizing plasma-sprayed hydroxyapatite?

خصائص الدراسة +
Population:
50 patients (55 hips) with non-inflammatory osteoarthritis (end-stage) of the hip
Intervention:
Intervention group received a 28-mm cobalt-chrome modular head coated with Bonemaster using electrochemical deposition (n=31)
Comparison:
Control group received a conventional 28-mm cobalt-chrome modular head with plasma-sprayed hydroxyapatite (n=24)
Outcomes:
Bone mineral density (BMD), Femoral stem migration (RSA), Harris Hip Score, Oxford Hip Score
Methods:
RCT; Multicenter
Time:
2 years post-operative
ما هي النتائج المهمة؟
  • The null hypothesis was rejected for BMD in Gruen zone 1 (p = .01); bone loss was less in the BM group. The null hypothesis was accepted for all other regions (p > .05)
  • No statistically significant results were obtained with respect to femoral migration or rotation following implantation (p > .05)
  • There were no significant differences in the Harris Hip Scores at two year follow-up between the groups (p > .05)
  • There were no significant differences in the oxford hip score between the two groups (p > .05)
ما الذي يجب أن أتذكره أكثر؟

Functional scores, migration, and rotation of the femoral head following total hip arthroplasty were not significantly different. Potential benefits in terms of bone mineral density were identified in favor of the Bonemaster group.

كيف سيؤثر ذلك على رعاية مرضاي؟

The results suggest that Bonemaster is clinically non-inferior to conventional plasma-sprayed hydroxyapatite and is a viable alternative. Long term follow-up is necessary to investigate other potential benefits of electrochemical deposition and whether or not long-term fixation is achieved. The small sample size of the study should be taken into account.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
Close Dialog
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Electrochemical versus plasma-coated femoral implant in total hip arthroplasty. OE Journal. 2013;1(12):47. Available from: https://myorthoevidence.com/AceReport/Show/electrochemical-versus-plasma-coated-femoral-implant-in-total-hip-arthroplasty

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report