ACE Report Cover
Electrochemical versus plasma-coated femoral implant in total hip arthroplasty
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descarregar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descarregar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
ARTHROPLASTY
Electrochemical versus plasma-coated femoral implant in total hip arthroplasty .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(12):47 Acta Orthop. 2011 Feb;82(1):13-9

50 patients undergoing total hip arthroplasty were randomized to receive either plasma-sprayed hydroxyapatite (HA) or electrochemically deposited hydroxyapatite (Bonemaster, BM),as a coating for the fixation of uncemented femoral stems, in order to compare the safety and efficacy of the two coatings. At a follow-up of two years, the two groups were similar in regards to their clinical outcomes.


Detalhes do financiamento da publicação +
Financiamento:
Industry funded
Patrocinador:
Biomet Europe
Conflitos:
None disclosed

Risco de viés

6/10

Critérios de notificação

17/20

Índice de Fragilidade

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

2/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

Alternative bone coatings, such as Bonemaster (BM), provide potential advantages in terms of remodelling and transporting of bone-active substances. The trial was necessary to investigate whether the use of this alternative is safe for conventional clinical use.

Qual era a principal questão de investigação?

In patients undergoing total hip arthroplasty for non-inflammatory osteoarthritis, does electrochemically deposited Bonemaster provide non-inferior results in terms of safety, as compared with a conventional femoral implant utilizing plasma-sprayed hydroxyapatite?

Caraterísticas do estudo +
População:
50 patients (55 hips) with non-inflammatory osteoarthritis (end-stage) of the hip
Intervenção:
Intervention group received a 28-mm cobalt-chrome modular head coated with Bonemaster using electrochemical deposition (n=31)
Comparação:
Control group received a conventional 28-mm cobalt-chrome modular head with plasma-sprayed hydroxyapatite (n=24)
Resultados:
Bone mineral density (BMD), Femoral stem migration (RSA), Harris Hip Score, Oxford Hip Score
Métodos:
RCT; Multicenter
Tempo:
2 years post-operative
Quais foram os resultados importantes?
  • The null hypothesis was rejected for BMD in Gruen zone 1 (p = .01); bone loss was less in the BM group. The null hypothesis was accepted for all other regions (p > .05)
  • No statistically significant results were obtained with respect to femoral migration or rotation following implantation (p > .05)
  • There were no significant differences in the Harris Hip Scores at two year follow-up between the groups (p > .05)
  • There were no significant differences in the oxford hip score between the two groups (p > .05)
De que é que me devo lembrar mais?

Functional scores, migration, and rotation of the femoral head following total hip arthroplasty were not significantly different. Potential benefits in terms of bone mineral density were identified in favor of the Bonemaster group.

Como é que isto afectará o tratamento dos meus doentes?

The results suggest that Bonemaster is clinically non-inferior to conventional plasma-sprayed hydroxyapatite and is a viable alternative. Long term follow-up is necessary to investigate other potential benefits of electrochemical deposition and whether or not long-term fixation is achieved. The small sample size of the study should be taken into account.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Close Dialog
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. Electrochemical versus plasma-coated femoral implant in total hip arthroplasty. OE Journal. 2013;1(12):47. Available from: https://myorthoevidence.com/AceReport/Show/electrochemical-versus-plasma-coated-femoral-implant-in-total-hip-arthroplasty

Copie a citação
Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Funcionalidade de Membro Premium

Para aceder a esta funcionalidade, tem de ter sessão iniciada numa conta Premium da OrthoEvidence.

Partilhe isto ACE Report