ARTHROPLASTY
TKA: All-polyethylene and metal-back tibial components result in successful outcomes .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(2):22 Acta Orthop. 2011 Oct;82(5):589-95. Epub 2011 Sep 6
Autores contribuintes

T Cheng G Zhang X Zhang

This meta-analysis and systematic review identified 9 randomized controlled trials that compared all-polyethylene (AP) tibial components to metal-backed (MB) tibial components in primary total knee arthroplasty. The results from this analysis demonstrate no significant difference in radiographic and clinical outcomes between both the AP and MB tibial component groups.


Detalhes do financiamento da publicação +
Financiamento:
Non-Industry funded
Patrocinador:
Shanghai Municipal Health Bureau.
Conflicts:
None disclosed

Risco de viés

6,5/10

Critérios de notificação

15/20

Índice de Fragilidade

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

4/4

Introduction

2/4

Accessing Data

4/4

Analysing Data

3/4

Results

2/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

Tibial component design is an extremely important aspect related to implant failure in total knee arthroplasty. The metal-backed (MB) tibial component design is more commonly used in TKA and is believed to result in better outcomes compared to the use of an all-polyethylene (AP) design. The MB component is thought to have several advantages; however, it is more expensive and can increase wear and tensile stresses during eccentric loading. Although several randomized trials have been performed evaluating the effectiveness of the MB component, this data has not been systematically analysed in order to determine the benefits of the MB component for patients.

Qual era a principal questão de investigação?

What are the outcomes of an all-polyethylene (AP) tibial component compared to a metal-back (MB) tibial component, in terms of radiographic and clinical outcomes in patients undergoing total knee arthroplasty?

Caraterísticas do estudo +
Data Source:
A search was conducted for randomized controlled trials using the internet databases PubMed (1985 to February 2009), EMBASE (1988 to February 2009), Scopus (1982 to February 2009), and the Cochrane Central Register of Controlled Trials (Issue 2, 2009). Further, manual searching of 7 journals (from 1990-2009) was completed for the Journal of Bone and Joint Surgery (American and British), Clinical Orthopaedics and Related Research, Acta Orthopaedica, The Knee, Knee Surgery Sports Traumatology Arthroscopy, and The Journal of Arthoplasty. The reference list of retrieved articles were screened.
Index Terms:
all-polyethylene, metal-backed, total knee arthroplasty, total knee replacement, TKA, and TKR.
Study Selection:
Studies included were randomized controlled trials that compared all-polyethylene (AP) tibial components to metal-backed (MB) tibial components in total knee arthroplasty. Two reviewers (TC and GZ) independently screened the titles and abstracts of the papers identified. Discrepancies in the study selection was resolved through discussion with the senior author (XZ).
Data Extraction:
Data extraction methods not described.
Data Synthesis:
Dichotomous outcomes were reported as risk ratios. I squared test for heterogeneity was performed for pooled data. A fixed effects model was used unless heterogeneity was present across studies. SPSS software version 13.0 and RevMan software version 5.0 were used.
Quais foram os resultados importantes?
  • The mean standardized Detsky score for the overall quality of the studies was 14 (SD 3).
  • The pooled results from 4 studies demonstrate that the evidence of radiolucent lines adjacent to the tibial component was higher in the MB group compared to the AP group (41 (27.7%) and 16 (10%), respectively) (RR=2.8, CI: 1.7-4.6; p<0.001; I^2=47%).
  • All of the studies demonstrated that there was no significant difference between the two groups with respect to functional outcomes, including Oxford Knee Score, Knee Society Score, Hospital for Special Surgery score, range of motion, quality of life and post-operative complications, as well as implant alignment.
De que é que me devo lembrar mais?

Similar radiologic and clinical results were observed with the use of both the AP and MB tibial components. The increase in frequency of radiolucent lines in the MB group did not lead to an increase in implant failure.

Como é que isto afectará o tratamento dos meus doentes?

The results from this meta-analysis indicate no functional differences between AP and MB tibial components for TKA. However, high quality randomized controlled trials are still required to validate these results.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. TKA: All-polyethylene and metal-back tibial components result in successful outcomes. OE Journal. 2013;1(2):22. Available from: https://myorthoevidence.com/AceReport/Show/tka-all-polyethylene-and-metal-back-tibial-components-result-in-successful-outcomes