ARTHROPLASTY
TKA: All-polyethylene and metal-back tibial components result in successful outcomes .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(2):22 Acta Orthop. 2011 Oct;82(5):589-95. Epub 2011 Sep 6
المؤلفون المساهمون

T Cheng G Zhang X Zhang

This meta-analysis and systematic review identified 9 randomized controlled trials that compared all-polyethylene (AP) tibial components to metal-backed (MB) tibial components in primary total knee arthroplasty. The results from this analysis demonstrate no significant difference in radiographic and clinical outcomes between both the AP and MB tibial component groups.


تفاصيل تمويل المنشور +
التمويل:
Non-Industry funded
الراعي:
Shanghai Municipal Health Bureau.
Conflicts:
None disclosed

مخاطر التحيز

6٫5/10

معايير الإبلاغ

15/20

مؤشر الهشاشة

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Introduction

2/4

Accessing Data

4/4

Analysing Data

3/4

Results

2/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Tibial component design is an extremely important aspect related to implant failure in total knee arthroplasty. The metal-backed (MB) tibial component design is more commonly used in TKA and is believed to result in better outcomes compared to the use of an all-polyethylene (AP) design. The MB component is thought to have several advantages; however, it is more expensive and can increase wear and tensile stresses during eccentric loading. Although several randomized trials have been performed evaluating the effectiveness of the MB component, this data has not been systematically analysed in order to determine the benefits of the MB component for patients.

ما هو سؤال البحث الرئيسي؟

What are the outcomes of an all-polyethylene (AP) tibial component compared to a metal-back (MB) tibial component, in terms of radiographic and clinical outcomes in patients undergoing total knee arthroplasty?

خصائص الدراسة +
Data Source:
A search was conducted for randomized controlled trials using the internet databases PubMed (1985 to February 2009), EMBASE (1988 to February 2009), Scopus (1982 to February 2009), and the Cochrane Central Register of Controlled Trials (Issue 2, 2009). Further, manual searching of 7 journals (from 1990-2009) was completed for the Journal of Bone and Joint Surgery (American and British), Clinical Orthopaedics and Related Research, Acta Orthopaedica, The Knee, Knee Surgery Sports Traumatology Arthroscopy, and The Journal of Arthoplasty. The reference list of retrieved articles were screened.
Index Terms:
all-polyethylene, metal-backed, total knee arthroplasty, total knee replacement, TKA, and TKR.
Study Selection:
Studies included were randomized controlled trials that compared all-polyethylene (AP) tibial components to metal-backed (MB) tibial components in total knee arthroplasty. Two reviewers (TC and GZ) independently screened the titles and abstracts of the papers identified. Discrepancies in the study selection was resolved through discussion with the senior author (XZ).
Data Extraction:
Data extraction methods not described.
Data Synthesis:
Dichotomous outcomes were reported as risk ratios. I squared test for heterogeneity was performed for pooled data. A fixed effects model was used unless heterogeneity was present across studies. SPSS software version 13.0 and RevMan software version 5.0 were used.
ما هي النتائج المهمة؟
  • The mean standardized Detsky score for the overall quality of the studies was 14 (SD 3).
  • The pooled results from 4 studies demonstrate that the evidence of radiolucent lines adjacent to the tibial component was higher in the MB group compared to the AP group (41 (27.7%) and 16 (10%), respectively) (RR=2.8, CI: 1.7-4.6; p<0.001; I^2=47%).
  • All of the studies demonstrated that there was no significant difference between the two groups with respect to functional outcomes, including Oxford Knee Score, Knee Society Score, Hospital for Special Surgery score, range of motion, quality of life and post-operative complications, as well as implant alignment.
ما الذي يجب أن أتذكره أكثر؟

Similar radiologic and clinical results were observed with the use of both the AP and MB tibial components. The increase in frequency of radiolucent lines in the MB group did not lead to an increase in implant failure.

كيف سيؤثر ذلك على رعاية مرضاي؟

The results from this meta-analysis indicate no functional differences between AP and MB tibial components for TKA. However, high quality randomized controlled trials are still required to validate these results.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. TKA: All-polyethylene and metal-back tibial components result in successful outcomes. OE Journal. 2013;1(2):22. Available from: https://myorthoevidence.com/AceReport/Show/tka-all-polyethylene-and-metal-back-tibial-components-result-in-successful-outcomes

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report