ARTHROPLASTY
THA: Less transverse rotation of tantalum trabecular metal acetabular cup .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(2):18 Acta Orthop. 2011 Apr;82(2):155-60. Epub 2011 Mar 25

60 patients with noninflammatory hip arthritis were randomized to receive either a tantalum trabecular metal acetabular cup or titanium fiber-mesh cup, as part of the primary hip arthroplasty surgical procedure. The primary endpoint was cup migration. Bone mineral density and the Harris hip score were also evaluated. Results indicated positive early results with the tantalum trabecular metal cup on fixation outcomes, as well as comparable results on the secondary endpoint outcomes. A longer observation period is recommended to examine the effects over a longer time period.


Publication Funding Details +
Funding:
Industry funded
Sponsor:
Zimmer Inc.
Conflicts:
None disclosed

Risk of Bias

6/10

Reporting Criteria

16/20

Fragility Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Yes = 1

Uncertain = 0.5

Not Relevant = 0

No = 0

The Reporting Criteria Assessment evaluates the transparency with which authors report the methodological and trial characteristics of the trial within the publication. The assessment is divided into five categories which are presented below.

4/4

Randomization

3/4

Outcome Measurements

3/4

Inclusion / Exclusion

2/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

The Fragility Index is a tool that aids in the interpretation of significant findings, providing a measure of strength for a result. The Fragility Index represents the number of consecutive events that need to be added to a dichotomous outcome to make the finding no longer significant. A small number represents a weaker finding and a large number represents a stronger finding.

Why was this study needed now?

Initial stability is critical for an implant to achieve bone ingrowth. A number of clinical studies have shown good outcomes in bone ingrowth with trabecular metal. However, no published studies have examined this relationship with radiostereometric analysis (RSA). This study compares tantalum trabecular metal acetabular cups and titanium fiber-mesh cups in primary hip arthroplasty.

What was the principal research question?

What are the outcomes in cup migration, bone mineral density, and Harris hip scores with tantalum trabecular metal acetabular cups compared to titanium fibermesh cups, in patients with noninflammatory hip arthritis undergoing primary hip arthroplasty at 2 years?

Study Characteristics +
Population:
60 patients with noninflammatory hip arthritis (Male: 34, Female: 26) (Age: 52-76 years; Median: 62 years)
Intervention:
Tantalum trabecular metal acetabular cup (Monoblock cup, Zimmer) (n=30)
Comparison:
Uncemented cup with a titanium fiber-mesh surface (Trilogy cup, Zimmer) (n=30)
Outcomes:
Primary endpoint: cup migration within 2 years (early implant loosening) (Radiostereometric analysis); Secondary endpoints: change in bone mineral density, and change in Harris hip score (HHS) at 3 months
Methods:
RCT
Time:
2 years
What were the important findings?
  • Radiostereometric analysis (RSA) indicated minimal rotation and translation at the 2-year follow-up. No statistically significant difference was seen between the two groups on translation. The trabecular tantalum surface cups (Monoblock) had less rotation on the transverse axis compared to the titanium fiber-mesh cup (Trilogy) (Monoblock: Mean -0.01 degrees [95%CI: -0.11 to 0.12]; Trilogy: Mean -0.60 degrees [95%CI: -0.72 to -0.48]) (p=0.04)
  • Both groups reported a similar increase in Harris hip score at 3 months postoperatively from a score of 50 (28-70) to 92 (76-100) in the tantalum group and from 48 (34-64) to 95 (77-100) in the Trilogy group
  • Both groups had similar degrees of reduction in bone mineral density
What should I remember most?

Positive early results were seen for both implant cups in terms of fixation onto the acetabular host bone. RSA revealed both groups had minimal rotation and translation (with less rotation on the transverse axis for the tantalum group). Results also indicated similar reduction in bone mineral density and similar increase in Harris hip score.

How will this affect the care of my patients?

A study with a longer observation period is recommended to determine the long-term outcomes of the tantalum trabecular metal acetabular cups.

DISCLAIMER

This content found on this page is for informational purposes only and is not intended to be a substitute for professional medical advice, diagnosis, or treatment. If you require medical treatment, always seek the advice of your physician or go to your nearest emergency department. The opinions, beliefs, and viewpoints expressed by the individuals on the content found on this page do not reflect the opinions, beliefs, and viewpoints of OrthoEvidence.

0 of 4 monthly FREE articles unlocked
You've reached your limit of 4 free articles views this month

Access to OrthoEvidence for as little as $1.99 per week.

Stay connected with latest evidence. Cancel at any time.
  • Critical appraisals of the latest, high-impact randomized controlled trials and systematic reviews in orthopaedics
  • Access to OrthoEvidence podcast content, including collaborations with the Journal of Bone and Joint Surgery, interviews with internationally recognized surgeons, and roundtable discussions on orthopaedic news and topics
  • Subscription to The Pulse, a twice-weekly evidence-based newsletter designed to help you make better clinical decisions
Upgrade
Welcome Back!
Forgot Password?
Start your FREE trial today!

Your account will be affiliated with
and includes free access to OrthoEvidence


OR
Forgot Password?

OR
Please check your email

If an account exists with the provided email address, a password reset email will be sent to you. If you don't see an email, please check your spam or junk folder.

For further assistance, contact our support team.

Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Translate ACE Report

OrthoEvidence utilizes a third-party translation service to make content accessible in multiple languages. Please note that while every effort is made to ensure accuracy, translations may not always be perfect.

How to cite this ACE Report

OrthoEvidence. THA: Less transverse rotation of tantalum trabecular metal acetabular cup. OE Journal. 2013;1(2):18. Available from: https://myorthoevidence.com/AceReport/Show/tha-less-transverse-rotation-of-tantalum-trabecular-metal-acetabular-cup

Copy Citation
Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Premium Member Feature

To access this feature, you must be logged into a premium OrthoEvidence account.

Share this ACE Report