ACE Report Cover
THA: Less transverse rotation of tantalum trabecular metal acetabular cup
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
ARTHROPLASTY
THA: Less transverse rotation of tantalum trabecular metal acetabular cup .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(2):18 Acta Orthop. 2011 Apr;82(2):155-60. Epub 2011 Mar 25

60 patients with noninflammatory hip arthritis were randomized to receive either a tantalum trabecular metal acetabular cup or titanium fiber-mesh cup, as part of the primary hip arthroplasty surgical procedure. The primary endpoint was cup migration. Bone mineral density and the Harris hip score were also evaluated. Results indicated positive early results with the tantalum trabecular metal cup on fixation outcomes, as well as comparable results on the secondary endpoint outcomes. A longer observation period is recommended to examine the effects over a longer time period.


Dettagli sul finanziamento della pubblicazione +
Finanziamento:
Industry funded
Sponsor:
Zimmer Inc.
Conflitti:
None disclosed

Rischio di pregiudizio

6/10

Criteri di segnalazione

16/20

Indice di fragilità

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sì = 1

Incerto = 0,5

Non rilevante = 0

No = 0

La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.

4/4

Randomization

3/4

Outcome Measurements

3/4

Inclusion / Exclusion

2/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.

Perché questo studio era necessario ora?

Initial stability is critical for an implant to achieve bone ingrowth. A number of clinical studies have shown good outcomes in bone ingrowth with trabecular metal. However, no published studies have examined this relationship with radiostereometric analysis (RSA). This study compares tantalum trabecular metal acetabular cups and titanium fiber-mesh cups in primary hip arthroplasty.

Qual era la domanda di ricerca principale?

What are the outcomes in cup migration, bone mineral density, and Harris hip scores with tantalum trabecular metal acetabular cups compared to titanium fibermesh cups, in patients with noninflammatory hip arthritis undergoing primary hip arthroplasty at 2 years?

Caratteristiche dello studio +
Population:
60 patients with noninflammatory hip arthritis (Male: 34, Female: 26) (Age: 52-76 years; Median: 62 years)
Intervention:
Tantalum trabecular metal acetabular cup (Monoblock cup, Zimmer) (n=30)
Comparison:
Uncemented cup with a titanium fiber-mesh surface (Trilogy cup, Zimmer) (n=30)
Outcomes:
Primary endpoint: cup migration within 2 years (early implant loosening) (Radiostereometric analysis); Secondary endpoints: change in bone mineral density, and change in Harris hip score (HHS) at 3 months
Methods:
RCT
Time:
2 years
Quali erano i risultati importanti?
  • Radiostereometric analysis (RSA) indicated minimal rotation and translation at the 2-year follow-up. No statistically significant difference was seen between the two groups on translation. The trabecular tantalum surface cups (Monoblock) had less rotation on the transverse axis compared to the titanium fiber-mesh cup (Trilogy) (Monoblock: Mean -0.01 degrees [95%CI: -0.11 to 0.12]; Trilogy: Mean -0.60 degrees [95%CI: -0.72 to -0.48]) (p=0.04)
  • Both groups reported a similar increase in Harris hip score at 3 months postoperatively from a score of 50 (28-70) to 92 (76-100) in the tantalum group and from 48 (34-64) to 95 (77-100) in the Trilogy group
  • Both groups had similar degrees of reduction in bone mineral density
Che cosa devo ricordare di più?

Positive early results were seen for both implant cups in terms of fixation onto the acetabular host bone. RSA revealed both groups had minimal rotation and translation (with less rotation on the transverse axis for the tantalum group). Results also indicated similar reduction in bone mineral density and similar increase in Harris hip score.

Come influenzerà l'assistenza ai miei pazienti?

A study with a longer observation period is recommended to determine the long-term outcomes of the tantalum trabecular metal acetabular cups.

DISCLAIMER

Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.

0 di 4 articoli mensili GRATUITI sbloccati
Ha raggiunto il suo limite di 4 visualizzazioni di articoli gratuiti questo mese

Accesso a OrthoEvidence a soli 1,99 dollari a settimana.

Rimanga in contatto con le ultime prove. Può disdire in qualsiasi momento.
  • Valutazioni critiche dei più recenti studi randomizzati controllati ad alto impatto e delle revisioni sistematiche in ortopedia.
  • Accesso ai contenuti del podcast OrthoEvidence, tra cui collaborazioni con il Journal of Bone and Joint Surgery, interviste con chirurghi di fama internazionale e tavole rotonde su notizie e argomenti ortopedici.
  • Abbonamento a The Pulse, una newsletter bisettimanale basata sulle evidenze scientifiche, progettata per aiutarla a prendere decisioni cliniche migliori.
Upgrade
Close Dialog
Bentornato!
Ha dimenticato la password?
Inizi la sua prova gratuita oggi stesso!

Il suo account sarà affiliato a
e includerà l'accesso gratuito a OrthoEvidence


O
Ha dimenticato la password?

O
Controlli la sua e-mail

Se esiste un account con l'indirizzo e-mail fornito, le verrà inviata un'e-mail di reimpostazione della password. Se non vede l'e-mail, controlli la cartella spam o posta indesiderata.

Per ulteriore assistenza, contatti il nostro team di supporto.

Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Tradurre il Rapporto ACE

OrthoEvidence utilizza un servizio di traduzione di terze parti per rendere i contenuti accessibili in più lingue. Si prega di notare che, sebbene venga fatto ogni sforzo per garantire l'accuratezza, le traduzioni potrebbero non essere sempre perfette.

Come citare questo documento ACE Report

OrthoEvidence. THA: Less transverse rotation of tantalum trabecular metal acetabular cup. OE Journal. 2013;1(2):18. Available from: https://myorthoevidence.com/AceReport/Show/tha-less-transverse-rotation-of-tantalum-trabecular-metal-acetabular-cup

Copiare la citazione
Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Funzionalità per i membri Premium

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence Premium.

Condividi questo articolo ACE Report