ARTHROPLASTY
Metal release does not translate to increased metal allergy in metal-on-polyethylene THA .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(20):2 Acta Orthop. 2014 Aug;85(4):348-54. doi: 10.3109/17453674.2014.922730. Epub 2014 Jun 16.

54 patients with primary osteoarthritis were randomized to undergo either reintroduced metal-on-metal (MOM) total hip resurfacing arthroplasty or metal-on-polyethylene (MOP) total hip arthroplasty, with the purpose of determining if the added excretion of metal ions from MOM results in heightened prevalence of metal allergies. A significant increase in cobalt and chromium in the MOM group was observed throughout the 5 year study period, but did not translate to increased metal allergy.


Detalhes do financiamento da publicação +
Financiamento:
Not Reported
Conflitos:
None disclosed

Risco de viés

5/10

Critérios de notificação

17/20

Índice de Fragilidade

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

3/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

Metal-on-metal (MOM) total hip arthroplasties were the standard of care in the 1960's and 1970's, but researchers soon discovered MOM implants released high levels of cobalt, chromium, and nickel. Focus shifted towards metal-on-polyethylene (MOP) arthroplasties instead, which were later found to have a high incidence of osteolysis and aseptic loosening in young, active patients, which many consider an even greater problem. Consequently, MOM arthroplasties were reintroduced, but the risk of metal hypersensitivity has become an issue due to greater absolute number of wear particles. Based on the hypothesis that metal allergies can be caused by prolonged metal exposure, the aim of this study was to determine if MOM arthroplasties increased the incidence of metal allergies in exposed patients.

Qual era a principal questão de investigação?

Is there greater incidence of metal allergy in patients undergoing metal-on-metal total hip resurfacing arthroplasty compared to patients undergoing metal-on-polyethylene total hip arthroplasty 5 years post-surgery?

Caraterísticas do estudo +
População:
54 patients 50-65 years of age with primary osteoarthritis, acceptable bone quality to allow the insertion of a THA, and no regular intake of non-steroid anti-inflammatory drugs (44 patients participated in full 5 year follow-up).
Intervenção:
MOM Group: Patients underwent metal-on-metal total hip arthoplasty using a ReCap hip resurfacing system (Biomet) consisting of a cemented cobalt-chromium femoral component and a press fit, titanium porous-coated acetabular component with a cobalt-chromium core (n=26, 19 analyzed at 5 year follow-up; mean age at surgery: 64 (56-70), M=9/F=10).
Comparação:
MOP/COP Group: Patients underwent standard MOP/COP total hip arthoplasty using a hybrid implant consisting of a cemented Exeter stem (Stryker) and a cementless porous coated Mallory Head acetabular shell (Biomet). 10 patients received a stainless steel modular femoral head (metal-on-polyethylene- MOP group) while 15 patients received a ceramic modular femoral head (ceramic-on-polyethylene- COP group) (n=26, 25 analyzed at 5 year follow-up; mean age at surgery: 64 (57-70), M=7/F=18).
Resultados:
Outcomes of interest included excretion of metal ions measured using urine samples and hypersensitivity to metals evaluated by patch testing applied to the upper back of patients, lymphocyte transformation assay, and a questionnaire.
Métodos:
RCT
Tempo:
Urine samples were collected after surgery, 3 months postoperatively, and at 1, 2, and 5 year follow-ups. Hypersensitivity to metals was tested at the 5 year follow-up.
Quais foram os resultados importantes?
  • A significant 10- to 20- fold increase in cobalt and chromium was observed in the urine of the MOM group throughout the 5 year follow-up (p<0.05), while no differences were observed in patients receiving implants with MOP or COP.
  • The patch test revealed no significant difference in the incidence of metal hypersensitivity at 5 years between the MOM and MOP/COP groups, nor between MOP and COP patients (both p>0.05).
  • The lymphocyte transformation assay revealed no significant difference in cellular reactivity at 5 years between the MOM and MOP/COP groups, nor between MOP and COP patients (both p>0.05).
De que é que me devo lembrar mais?

The significant increase of cobalt and chromium levels throughout the 5 year study period did not translate to increased metal allergy in patients that underwent metal-on-metal (MOM) total hip arthroplasty.

Como é que isto afectará o tratamento dos meus doentes?

It appears MOM total hip arthoplasty does not increase the incidence of metal allergies, but the long-term effects of metal exposure still remain uncertain. Results must be interpreted with caution, as the metel-on-metal group lost 7 patients to final follow-up.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Close Dialog
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. Metal release does not translate to increased metal allergy in metal-on-polyethylene THA. OE Journal. 2014;2(20):2. Available from: https://myorthoevidence.com/AceReport/Show/metal-release-does-not-translate-to-increased-metal-allergy-in-metal-on-polyethylene-tha

Copie a citação
Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Funcionalidade de Membro Premium

Para aceder a esta funcionalidade, tem de ter sessão iniciada numa conta Premium da OrthoEvidence.

Partilhe isto ACE Report