ACE Report Cover
Metal release does not translate to increased metal allergy in metal-on-polyethylene THA
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り

ARTHROPLASTY

Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis 5-year follow-up of 52 patients

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(20):2 Acta Orthop. 2014 Aug;85(4):348-54. doi: 10.3109/17453674.2014.922730. Epub 2014 Jun 16.

54 patients with primary osteoarthritis were randomized to undergo either reintroduced metal-on-metal (MOM) total hip resurfacing arthroplasty or metal-on-polyethylene (MOP) total hip arthroplasty, with the purpose of determining if the added excretion of metal ions from MOM results in heightened prevalence of metal allergies. A significant increase in cobalt and chromium in the MOM group was observed throughout the 5 year study period, but did not translate to increased metal allergy.


出版資金提供の詳細 +
資金提供:
Not Reported
コンフリクト:
None disclosed

バイアスのリスク

5/10

報告基準

17/20

脆弱性指数

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

はい = 1

不確実=0.5

無関係 = 0

いいえ = 0

報告基準評価では、著者が出版物内で試験の方法論的特徴や試験特性を報告する際の透明性を評価します。評価は以下の5つのカテゴリーに分類されます。

3/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Fragility Indexは、重要な所見の解釈を助けるツールで、結果の強さの尺度を提供します。Fragility Indexは、その所見が有意でなくなるために、二項対立の結果に追加する必要がある連続した事象の数を表します。数値が小さいほど弱い所見を表し、数値が大きいほど強い所見を表します。

なぜ今この研究が必要なのですか?

Metal-on-metal (MOM) total hip arthroplasties were the standard of care in the 1960's and 1970's, but researchers soon discovered MOM implants released high levels of cobalt, chromium, and nickel. Focus shifted towards metal-on-polyethylene (MOP) arthroplasties instead, which were later found to have a high incidence of osteolysis and aseptic loosening in young, active patients, which many consider an even greater problem. Consequently, MOM arthroplasties were reintroduced, but the risk of metal hypersensitivity has become an issue due to greater absolute number of wear particles. Based on the hypothesis that metal allergies can be caused by prolonged metal exposure, the aim of this study was to determine if MOM arthroplasties increased the incidence of metal allergies in exposed patients.

主な研究課題は何ですか?

Is there greater incidence of metal allergy in patients undergoing metal-on-metal total hip resurfacing arthroplasty compared to patients undergoing metal-on-polyethylene total hip arthroplasty 5 years post-surgery?

研究の特徴 +
人口:
54 patients 50-65 years of age with primary osteoarthritis, acceptable bone quality to allow the insertion of a THA, and no regular intake of non-steroid anti-inflammatory drugs (44 patients participated in full 5 year follow-up).
介入:
MOM Group: Patients underwent metal-on-metal total hip arthoplasty using a ReCap hip resurfacing system (Biomet) consisting of a cemented cobalt-chromium femoral component and a press fit, titanium porous-coated acetabular component with a cobalt-chromium core (n=26, 19 analyzed at 5 year follow-up; mean age at surgery: 64 (56-70), M=9/F=10).
比較:
MOP/COP Group: Patients underwent standard MOP/COP total hip arthoplasty using a hybrid implant consisting of a cemented Exeter stem (Stryker) and a cementless porous coated Mallory Head acetabular shell (Biomet). 10 patients received a stainless steel modular femoral head (metal-on-polyethylene- MOP group) while 15 patients received a ceramic modular femoral head (ceramic-on-polyethylene- COP group) (n=26, 25 analyzed at 5 year follow-up; mean age at surgery: 64 (57-70), M=7/F=18).
アウトカム:
Outcomes of interest included excretion of metal ions measured using urine samples and hypersensitivity to metals evaluated by patch testing applied to the upper back of patients, lymphocyte transformation assay, and a questionnaire.
方法:
RCT
時間:
Urine samples were collected after surgery, 3 months postoperatively, and at 1, 2, and 5 year follow-ups. Hypersensitivity to metals was tested at the 5 year follow-up.

重要な知見は?

  • A significant 10- to 20- fold increase in cobalt and chromium was observed in the urine of the MOM group throughout the 5 year follow-up (p<0.05), while no differences were observed in patients receiving implants with MOP or COP.
  • The patch test revealed no significant difference in the incidence of metal hypersensitivity at 5 years between the MOM and MOP/COP groups, nor between MOP and COP patients (both p>0.05).
  • The lymphocyte transformation assay revealed no significant difference in cellular reactivity at 5 years between the MOM and MOP/COP groups, nor between MOP and COP patients (both p>0.05).
最も覚えておくべきことは?

The significant increase of cobalt and chromium levels throughout the 5 year study period did not translate to increased metal allergy in patients that underwent metal-on-metal (MOM) total hip arthroplasty.

それが私の患者ケアにどのように影響するか?

It appears MOM total hip arthoplasty does not increase the incidence of metal allergies, but the long-term effects of metal exposure still remain uncertain. Results must be interpreted with caution, as the metel-on-metal group lost 7 patients to final follow-up.

免責事項

このページに記載されている内容は、情報提供のみを目的としたものであり、専門的な医療アドバイス、診断、治療の代わりとなるものではありません。治療が必要な場合は、必ず医師の診断を仰ぐか、最寄りの救急外来を受診してください。このページに記載されている内容に関して個人が表明した意見、信念、見解は、OrthoEvidenceの意見、信念、見解を反映するものではありません。

0の4 月間無料記事のロック解除
今月の無料記事閲覧数が4件に達しました。

週1.99ドルからOrthoEvidenceにアクセスできます。

最新のエビデンスにアクセスしてください。いつでもキャンセルできます。
  • 整形外科における最新のインパクトのあるランダム化比較試験とシステマティックレビューの批判的評価
  • Journal of Bone and Joint Surgeryとのコラボレーション、国際的に著名な外科医へのインタビュー、整形外科ニュースやトピックに関する座談会など、OrthoEvidenceポッドキャストコンテンツへのアクセス
  • 週2回発行されるエビデンスに基づくニュースレター、The Pulseの購読。
Upgrade
Close Dialog
おかえりなさい
パスワードをお忘れですか?
今すぐ無料トライアルを開始

あなたのアカウントは
OrthoEvidenceへの無料アクセスが含まれます。


または
パスワードをお忘れですか?

または
Eメールをご確認ください

入力されたメールアドレスにアカウントが存在する場合、パスワードリセットのメールが送信されます。メールが届かない場合は、迷惑メールフォルダをご確認ください。

その他のサポート サポートチームまでご連絡ください。.

この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

ACEレポートを翻訳

OrthoEvidenceは、多言語でコンテンツにアクセスできるようにするため、第三者の翻訳サービスを利用しています。正確性を確保するためにあらゆる努力をしていますが、翻訳が必ずしも完璧ではない可能性があることにご注意ください。

引用方法 ACE Report

OrthoEvidence. Metal release does not translate to increased metal allergy in metal-on-polyethylene THA. OE Journal. 2014;2(20):2. Available from: https://myorthoevidence.com/AceReport/Show/metal-release-does-not-translate-to-increased-metal-allergy-in-metal-on-polyethylene-tha

引用のコピー
この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

プレミアム会員機能

この機能にアクセスするには、OrthoEvidenceのプレミアムアカウントにログインする必要があります。

共有 ACE Report