ACE Report Cover
Metal release does not translate to increased metal allergy in metal-on-polyethylene THA
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Sprache
Download Download Download
Herunterladen
Cite this Report Cite this Report Cite this Report
Zitieren
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoriten
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Sprache
Download Download Download
Herunterladen
Cite this Report Cite this Report Cite this Report
Zitieren
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoriten
ARTHROPLASTY
Metal release does not translate to increased metal allergy in metal-on-polyethylene THA .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(20):2 Acta Orthop. 2014 Aug;85(4):348-54. doi: 10.3109/17453674.2014.922730. Epub 2014 Jun 16.

54 patients with primary osteoarthritis were randomized to undergo either reintroduced metal-on-metal (MOM) total hip resurfacing arthroplasty or metal-on-polyethylene (MOP) total hip arthroplasty, with the purpose of determining if the added excretion of metal ions from MOM results in heightened prevalence of metal allergies. A significant increase in cobalt and chromium in the MOM group was observed throughout the 5 year study period, but did not translate to increased metal allergy.


Details zur Finanzierung der Veröffentlichung +
Finanzierung:
Not Reported
Interessenkonflikte:
None disclosed

Risiko der Voreingenommenheit

5/10

Kriterien für die Berichterstattung

17/20

Fragilitäts-Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Ja = 1

Ungewiss = 0.5

Nicht relevant = 0

Nein = 0

Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.

3/4

Aleatorización

2/4

Medición de resultados

4/4

Inclusión / exclusión

4/4

Descripción de la terapia

4/4

Estadísticas

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.

Warum wurde diese Studie jetzt benötigt?

Metal-on-metal (MOM) total hip arthroplasties were the standard of care in the 1960's and 1970's, but researchers soon discovered MOM implants released high levels of cobalt, chromium, and nickel. Focus shifted towards metal-on-polyethylene (MOP) arthroplasties instead, which were later found to have a high incidence of osteolysis and aseptic loosening in young, active patients, which many consider an even greater problem. Consequently, MOM arthroplasties were reintroduced, but the risk of metal hypersensitivity has become an issue due to greater absolute number of wear particles. Based on the hypothesis that metal allergies can be caused by prolonged metal exposure, the aim of this study was to determine if MOM arthroplasties increased the incidence of metal allergies in exposed patients.

Was war die wichtigste Forschungsfrage?

Is there greater incidence of metal allergy in patients undergoing metal-on-metal total hip resurfacing arthroplasty compared to patients undergoing metal-on-polyethylene total hip arthroplasty 5 years post-surgery?

Merkmale der Studie +
Bevölkerung:
54 patients 50-65 years of age with primary osteoarthritis, acceptable bone quality to allow the insertion of a THA, and no regular intake of non-steroid anti-inflammatory drugs (44 patients participated in full 5 year follow-up).
Intervention:
MOM Group: Patients underwent metal-on-metal total hip arthoplasty using a ReCap hip resurfacing system (Biomet) consisting of a cemented cobalt-chromium femoral component and a press fit, titanium porous-coated acetabular component with a cobalt-chromium core (n=26, 19 analyzed at 5 year follow-up; mean age at surgery: 64 (56-70), M=9/F=10).
Vergleich:
MOP/COP Group: Patients underwent standard MOP/COP total hip arthoplasty using a hybrid implant consisting of a cemented Exeter stem (Stryker) and a cementless porous coated Mallory Head acetabular shell (Biomet). 10 patients received a stainless steel modular femoral head (metal-on-polyethylene- MOP group) while 15 patients received a ceramic modular femoral head (ceramic-on-polyethylene- COP group) (n=26, 25 analyzed at 5 year follow-up; mean age at surgery: 64 (57-70), M=7/F=18).
Ergebnisse:
Outcomes of interest included excretion of metal ions measured using urine samples and hypersensitivity to metals evaluated by patch testing applied to the upper back of patients, lymphocyte transformation assay, and a questionnaire.
Methoden:
RCT
Zeit:
Urine samples were collected after surgery, 3 months postoperatively, and at 1, 2, and 5 year follow-ups. Hypersensitivity to metals was tested at the 5 year follow-up.
Was waren die wichtigsten Ergebnisse?
  • A significant 10- to 20- fold increase in cobalt and chromium was observed in the urine of the MOM group throughout the 5 year follow-up (p<0.05), while no differences were observed in patients receiving implants with MOP or COP.
  • The patch test revealed no significant difference in the incidence of metal hypersensitivity at 5 years between the MOM and MOP/COP groups, nor between MOP and COP patients (both p>0.05).
  • The lymphocyte transformation assay revealed no significant difference in cellular reactivity at 5 years between the MOM and MOP/COP groups, nor between MOP and COP patients (both p>0.05).
Was sollte ich mir besonders merken?

The significant increase of cobalt and chromium levels throughout the 5 year study period did not translate to increased metal allergy in patients that underwent metal-on-metal (MOM) total hip arthroplasty.

Wie wird sich dies auf die Behandlung meiner Patienten auswirken?

It appears MOM total hip arthoplasty does not increase the incidence of metal allergies, but the long-term effects of metal exposure still remain uncertain. Results must be interpreted with caution, as the metel-on-metal group lost 7 patients to final follow-up.

HAFTUNGSAUSSCHLUSS

Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.

0 von 4 monatliche KOSTENLOSE Artikel freigeschaltet
Sie haben Ihr Limit von 4 kostenlosen Artikeln in diesem Monat erreicht

Zugang zu OrthoEvidence für nur $1,99 pro Woche.

Bleiben Sie auf dem Laufenden mit den neuesten Beweisen. Jederzeit kündbar.
  • Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
  • Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
  • Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Upgrade
Close Dialog
Willkommen zurück!
Passwort vergessen?
Starten Sie Ihre KOSTENLOSE Testversion noch heute!

Ihr Konto ist verbunden mit
und umfasst den kostenlosen Zugang zu OrthoEvidence


ODER
Passwort vergessen?

ODER
Bitte überprüfen Sie Ihre E-Mail

Wenn ein Konto mit der angegebenen E-Mail-Adresse existiert, wird Ihnen eine E-Mail zum Zurücksetzen des Passworts zugesandt. Wenn Sie keine E-Mail sehen, überprüfen Sie bitte Ihren Spam- oder Junk-Ordner.

Für weitere Hilfe, kontaktieren Sie unser Support-Team.

Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Übersetzen ACE Report

OrthoEvidence nutzt einen externen Übersetzungsdienst, um Inhalte in mehreren Sprachen zugänglich zu machen. Bitte beachten Sie, dass trotz aller Bemühungen um Genauigkeit die Übersetzungen nicht immer perfekt sind.

Wie man dies zitiert ACE Report

OrthoEvidence. Metal release does not translate to increased metal allergy in metal-on-polyethylene THA. OE Journal. 2014;2(20):2. Available from: https://myorthoevidence.com/AceReport/Show/metal-release-does-not-translate-to-increased-metal-allergy-in-metal-on-polyethylene-tha