ARTHROPLASTY
Metal release does not translate to increased metal allergy in metal-on-polyethylene THA .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(20):2 Acta Orthop. 2014 Aug;85(4):348-54. doi: 10.3109/17453674.2014.922730. Epub 2014 Jun 16.

54 patients with primary osteoarthritis were randomized to undergo either reintroduced metal-on-metal (MOM) total hip resurfacing arthroplasty or metal-on-polyethylene (MOP) total hip arthroplasty, with the purpose of determining if the added excretion of metal ions from MOM results in heightened prevalence of metal allergies. A significant increase in cobalt and chromium in the MOM group was observed throughout the 5 year study period, but did not translate to increased metal allergy.


تفاصيل تمويل المنشور +
التمويل:
Not Reported
التعارضات:
None disclosed

مخاطر التحيز

5/10

معايير الإبلاغ

17/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

3/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Metal-on-metal (MOM) total hip arthroplasties were the standard of care in the 1960's and 1970's, but researchers soon discovered MOM implants released high levels of cobalt, chromium, and nickel. Focus shifted towards metal-on-polyethylene (MOP) arthroplasties instead, which were later found to have a high incidence of osteolysis and aseptic loosening in young, active patients, which many consider an even greater problem. Consequently, MOM arthroplasties were reintroduced, but the risk of metal hypersensitivity has become an issue due to greater absolute number of wear particles. Based on the hypothesis that metal allergies can be caused by prolonged metal exposure, the aim of this study was to determine if MOM arthroplasties increased the incidence of metal allergies in exposed patients.

ما هو سؤال البحث الرئيسي؟

Is there greater incidence of metal allergy in patients undergoing metal-on-metal total hip resurfacing arthroplasty compared to patients undergoing metal-on-polyethylene total hip arthroplasty 5 years post-surgery?

خصائص الدراسة +
Population:
54 patients 50-65 years of age with primary osteoarthritis, acceptable bone quality to allow the insertion of a THA, and no regular intake of non-steroid anti-inflammatory drugs (44 patients participated in full 5 year follow-up).
Intervention:
MOM Group: Patients underwent metal-on-metal total hip arthoplasty using a ReCap hip resurfacing system (Biomet) consisting of a cemented cobalt-chromium femoral component and a press fit, titanium porous-coated acetabular component with a cobalt-chromium core (n=26, 19 analyzed at 5 year follow-up; mean age at surgery: 64 (56-70), M=9/F=10).
Comparison:
MOP/COP Group: Patients underwent standard MOP/COP total hip arthoplasty using a hybrid implant consisting of a cemented Exeter stem (Stryker) and a cementless porous coated Mallory Head acetabular shell (Biomet). 10 patients received a stainless steel modular femoral head (metal-on-polyethylene- MOP group) while 15 patients received a ceramic modular femoral head (ceramic-on-polyethylene- COP group) (n=26, 25 analyzed at 5 year follow-up; mean age at surgery: 64 (57-70), M=7/F=18).
Outcomes:
Outcomes of interest included excretion of metal ions measured using urine samples and hypersensitivity to metals evaluated by patch testing applied to the upper back of patients, lymphocyte transformation assay, and a questionnaire.
Methods:
RCT
Time:
Urine samples were collected after surgery, 3 months postoperatively, and at 1, 2, and 5 year follow-ups. Hypersensitivity to metals was tested at the 5 year follow-up.
ما هي النتائج المهمة؟
  • A significant 10- to 20- fold increase in cobalt and chromium was observed in the urine of the MOM group throughout the 5 year follow-up (p<0.05), while no differences were observed in patients receiving implants with MOP or COP.
  • The patch test revealed no significant difference in the incidence of metal hypersensitivity at 5 years between the MOM and MOP/COP groups, nor between MOP and COP patients (both p>0.05).
  • The lymphocyte transformation assay revealed no significant difference in cellular reactivity at 5 years between the MOM and MOP/COP groups, nor between MOP and COP patients (both p>0.05).
ما الذي يجب أن أتذكره أكثر؟

The significant increase of cobalt and chromium levels throughout the 5 year study period did not translate to increased metal allergy in patients that underwent metal-on-metal (MOM) total hip arthroplasty.

كيف سيؤثر ذلك على رعاية مرضاي؟

It appears MOM total hip arthoplasty does not increase the incidence of metal allergies, but the long-term effects of metal exposure still remain uncertain. Results must be interpreted with caution, as the metel-on-metal group lost 7 patients to final follow-up.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
Close Dialog
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Metal release does not translate to increased metal allergy in metal-on-polyethylene THA. OE Journal. 2014;2(20):2. Available from: https://myorthoevidence.com/AceReport/Show/metal-release-does-not-translate-to-increased-metal-allergy-in-metal-on-polyethylene-tha