ARTHROPLASTY

Elevation of circulating HLA DR(+) CD8(+) T-cells and correlation with chromium and cobalt concentrations 6 years after metal-on-metal hip arthroplasty

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2025;13(20):1 Acta Orthop. 2011 Feb;82(1):6-12. Epub 2010 Dec 29

85 patients undergoing total hip arthroplasty (THA) were randomized to receive either a metal-on-metal bearing or a metal-on-polyethylene bearing. The primary outcome was elevation of circulating HLA DR+ CD8+ T-cells and correlation with chromium and cobalt concentrations. Results indicated that metal-on-metal THA increased chromium and cobalt concentrations which resulted in a correlation with immunological reactions. This was associated with the increase in HLA DR+CD8+ T-cells and a decrease in B-cells.


Details zur Finanzierung der Veröffentlichung +
Finanzierung:
Non-Industry funded
Sponsor:
Sven Noren Bequest Fund
Interessenkonflikte:
None disclosed

Risiko der Voreingenommenheit

4/10

Kriterien für die Berichterstattung

16/20

Fragilitäts-Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Ja = 1

Ungewiss = 0.5

Nicht relevant = 0

Nein = 0

Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.

1/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.

Warum wurde diese Studie jetzt benötigt?

Elevated metal ion concentrations from metal-on-metal arthroplasties have been associated with immunological reactions. It is hypothesized that an increased concentration of metal ions causes changes in the lymphocyte sub-populations. This study examines the change in concentration of HLA DR+ CD8+ T-cells and the correlation with chromium and cobalt concentrations in patients undergoing metal-on-metal or metal-on-polyethylene total hip arthroplasty (THA).

Was war die wichtigste Forschungsfrage?

What are the outcomes in HLA DR+ CD8+ T-cell elevation and its correlation with chromium and cobalt concentrations in patients, 6 years after undergoing metal-on-metal total hip arthroplasty (THA) compared to metal-on-polyethylene THA?

Merkmale der Studie +
Bevölkerung:
85 patients undergoing total hip arthroplasty (THA) (Age: 40-75 years)
Intervention:
Metal-on-metal total hip arthroplasty. A high-carbon cobalt-chromium alloy against a cobalt-chromium liner in a polyethylene cup. A standard posterior approach was used for THA. (n=41)
Vergleich:
Metal-on-polyethylene total hip arthroplasty. Cobalt chromium head against an all-polyethylene cup. A standard posterior approach was used for THA. (n=44)
Ergebnisse:
Chromium, cobalt, manganese, and nickel concentration (measured by high-resolution inductively coupled plasma mass spectrometry), leukocyte sub-populations and immunoglobulins in patient blood (measured by standard laboratory methods), implant migration relative to surrounding bone, and Harris Hip Score (HHS)
Methoden:
RCT
Zeit:
Mean 82 (72-97) months. (Follow-up at 3, 6, 12, 24, and 72 months)

Was waren die wichtigsten Ergebnisse?

  • Serum concentrations of chromium and cobalt were higher in patients who received the metal-on-metal total hip arthroplasty (THA) compared to patients who underwent metal-on-polyethylene THA when examined at follow-up. (Chromium: 1.05 vs. 0.36 ug/L; p<0.001; Cobalt: 0.86 vs. 0.24 ug/L; p<0.001)
  • The metal-on-metal group had a higher percentage of HLA DR+ CD8+ T-cells. (10.6 vs. 6.7%; p=0.03) This had a positive correlation with cobalt and chromium concentrations in patient blood (Pearson's correlation coefficient for cobalt: 0.36, p=0.03; Chromium: 0.39, p=0.02).
  • The metal-on-metal group had a lower percentage of B-cells.(9.3% compared to 12.9% in the metal-on-polyethylene group) (p=0.01)
  • Comparable immunoglobulin concentrations and Harris hip scores were seen between the two groups. No radiographic signs of loosening, wear or periprosthetic osteolysis were seen with either group at follow-up.
  • Both groups of patients had similar concentrations of immunoglobulins IgG (and subgroups 1-4), IgM, and IgA.
Was sollte ich mir besonders merken?

Metal-on-metal THA increases cobalt and chromium concentrations at 6-years and produces immunological alterations. There is also a positive correlation with HLA DR+ CD8+ T-cells and chromium and cobalt concentrations. Finally, the metal-on-metal group had a reduction in the percentage of B-cells.

Wie wird sich dies auf die Behandlung meiner Patienten auswirken?

There is still a lack of evidence that the increase in HLA DR+ CD8+ T-cells, associated with metal-on-metal THA, causes allergic reactions, aseptic loosening, or periprosthetic pseudotumors. Further studies with a larger population are required to examine these potential associations.

HAFTUNGSAUSSCHLUSS

Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.

0 von 4 monatliche KOSTENLOSE Artikel freigeschaltet
Sie haben Ihr Limit von 4 kostenlosen Artikeln in diesem Monat erreicht

Zugang zu OrthoEvidence für nur $1,99 pro Woche.

Bleiben Sie auf dem Laufenden mit den neuesten Beweisen. Jederzeit kündbar.
  • Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
  • Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
  • Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Upgrade
Close Dialog
Willkommen zurück!
Passwort vergessen?
Starten Sie Ihre KOSTENLOSE Testversion noch heute!

Ihr Konto ist verbunden mit
und umfasst den kostenlosen Zugang zu OrthoEvidence


ODER
Passwort vergessen?

ODER
Bitte überprüfen Sie Ihre E-Mail

Wenn ein Konto mit der angegebenen E-Mail-Adresse existiert, wird Ihnen eine E-Mail zum Zurücksetzen des Passworts zugesandt. Wenn Sie keine E-Mail sehen, überprüfen Sie bitte Ihren Spam- oder Junk-Ordner.

Für weitere Hilfe, kontaktieren Sie unser Support-Team.

Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Übersetzen ACE Report

OrthoEvidence nutzt einen externen Übersetzungsdienst, um Inhalte in mehreren Sprachen zugänglich zu machen. Bitte beachten Sie, dass trotz aller Bemühungen um Genauigkeit die Übersetzungen nicht immer perfekt sind.

Wie man dies zitiert ACE Report

OrthoEvidence. Metal-on-metal THA increases HLA DR+CD8+ T-cells & correlates with immunological reactions. OE Journal. 2025;13(20):1. Available from: https://myorthoevidence.com/AceReport/Show/

Zitat kopieren
Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Premium-Mitglied-Funktion

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem Premium-Konto von OrthoEvidence angemeldet sein.

Teilen Sie dies ACE Report