ARTHROPLASTY

Elevation of circulating HLA DR(+) CD8(+) T-cells and correlation with chromium and cobalt concentrations 6 years after metal-on-metal hip arthroplasty

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2025;13(20):1 Acta Orthop. 2011 Feb;82(1):6-12. Epub 2010 Dec 29

المؤلفون المساهمون

NP Hailer RA Blaheta H Dahlstrand A Stark

85 patients undergoing total hip arthroplasty (THA) were randomized to receive either a metal-on-metal bearing or a metal-on-polyethylene bearing. The primary outcome was elevation of circulating HLA DR+ CD8+ T-cells and correlation with chromium and cobalt concentrations. Results indicated that metal-on-metal THA increased chromium and cobalt concentrations which resulted in a correlation with immunological reactions. This was associated with the increase in HLA DR+CD8+ T-cells and a decrease in B-cells.


تفاصيل تمويل المنشور +
التمويل:
Non-Industry funded
الراعي:
Sven Noren Bequest Fund
التعارضات:
None disclosed

مخاطر التحيز

4/10

معايير الإبلاغ

16/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

1/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Elevated metal ion concentrations from metal-on-metal arthroplasties have been associated with immunological reactions. It is hypothesized that an increased concentration of metal ions causes changes in the lymphocyte sub-populations. This study examines the change in concentration of HLA DR+ CD8+ T-cells and the correlation with chromium and cobalt concentrations in patients undergoing metal-on-metal or metal-on-polyethylene total hip arthroplasty (THA).

ما هو سؤال البحث الرئيسي؟

What are the outcomes in HLA DR+ CD8+ T-cell elevation and its correlation with chromium and cobalt concentrations in patients, 6 years after undergoing metal-on-metal total hip arthroplasty (THA) compared to metal-on-polyethylene THA?

خصائص الدراسة +
السكان:
85 patients undergoing total hip arthroplasty (THA) (Age: 40-75 years)
التدخل:
Metal-on-metal total hip arthroplasty. A high-carbon cobalt-chromium alloy against a cobalt-chromium liner in a polyethylene cup. A standard posterior approach was used for THA. (n=41)
المقارنة:
Metal-on-polyethylene total hip arthroplasty. Cobalt chromium head against an all-polyethylene cup. A standard posterior approach was used for THA. (n=44)
النتائج:
Chromium, cobalt, manganese, and nickel concentration (measured by high-resolution inductively coupled plasma mass spectrometry), leukocyte sub-populations and immunoglobulins in patient blood (measured by standard laboratory methods), implant migration relative to surrounding bone, and Harris Hip Score (HHS)
الأساليب:
RCT
الوقت:
Mean 82 (72-97) months. (Follow-up at 3, 6, 12, 24, and 72 months)

ما هي النتائج المهمة؟

  • Serum concentrations of chromium and cobalt were higher in patients who received the metal-on-metal total hip arthroplasty (THA) compared to patients who underwent metal-on-polyethylene THA when examined at follow-up. (Chromium: 1.05 vs. 0.36 ug/L; p<0.001; Cobalt: 0.86 vs. 0.24 ug/L; p<0.001)
  • The metal-on-metal group had a higher percentage of HLA DR+ CD8+ T-cells. (10.6 vs. 6.7%; p=0.03) This had a positive correlation with cobalt and chromium concentrations in patient blood (Pearson's correlation coefficient for cobalt: 0.36, p=0.03; Chromium: 0.39, p=0.02).
  • The metal-on-metal group had a lower percentage of B-cells.(9.3% compared to 12.9% in the metal-on-polyethylene group) (p=0.01)
  • Comparable immunoglobulin concentrations and Harris hip scores were seen between the two groups. No radiographic signs of loosening, wear or periprosthetic osteolysis were seen with either group at follow-up.
  • Both groups of patients had similar concentrations of immunoglobulins IgG (and subgroups 1-4), IgM, and IgA.
ما الذي يجب أن أتذكره أكثر؟

Metal-on-metal THA increases cobalt and chromium concentrations at 6-years and produces immunological alterations. There is also a positive correlation with HLA DR+ CD8+ T-cells and chromium and cobalt concentrations. Finally, the metal-on-metal group had a reduction in the percentage of B-cells.

كيف سيؤثر ذلك على رعاية مرضاي؟

There is still a lack of evidence that the increase in HLA DR+ CD8+ T-cells, associated with metal-on-metal THA, causes allergic reactions, aseptic loosening, or periprosthetic pseudotumors. Further studies with a larger population are required to examine these potential associations.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
Close Dialog
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Metal-on-metal THA increases HLA DR+CD8+ T-cells & correlates with immunological reactions. OE Journal. 2025;13(20):1. Available from: https://myorthoevidence.com/AceReport/Show/

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report