Volar locked plating of dorsally displaced fractures of the distal radius .
OrthoEvidence Journal (OE Journal) - ACE Report
OE Journal. 2013;1(2):97 Acta Orthop. 2011 Feb;82(1):76-81.63 patients with distal radius fractures were randomized to treatment with either volar locked plating or bridging external fixation, to compare functional and radiographic outcomes. Short-term outcomes at 3 and 6 months favored the volar locked plating group in terms of Disabilities of the Arm, Shoulder, and Hand (DASH) scores,Patient related wrist evaluation (PRWE) scores, grip strength and range of motion. However, by 12 months, many of the outcomes between the two groups had become similar.
Was the allocation sequence adequately generated?
Was allocation adequately concealed?
Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?
Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?
Blinding Patients: Was knowledge of the allocated interventions adequately prevented?
Was loss to follow-up (missing outcome data) infrequent?
Are reports of the study free of suggestion of selective outcome reporting?
Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?
Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?
Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?
Sì = 1
Incerto = 0,5
Non rilevante = 0
No = 0
La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.
3/4
Randomization
3/4
Outcome Measurements
4/4
Inclusion / Exclusion
4/4
Therapy Description
4/4
Statistics
Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65
L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.
Perché questo studio era necessario ora?
Recent studies have indicated promising patient outcomes for open reduction and internal fixation with volar locked plating of unstable distal radius fractures with dorsal displacement. Proposed benefits include adequate fracture stabilization and anatomic reduction, expediting early range of motion. However, the choice of internal fixation over external fixation remains unsupported in the literature. Thus, this study was required to investigate the functional and radiographic outcomes of volar locked plating.
Qual era la domanda di ricerca principale?
Does internal fixation with volar locked plating provide superior outcomes in terms of function and radiographic measures compared to external fixation, in patients with dorsally displaced fracture of the distal radius?
- Statistically significant improvements in DASH scores were observed in the volar-plated group versus the external fixation group at the 3 month (9 vs. 27; p<0.001) and 6 month follow-ups (6 vs. 14; p=0.008). This result failed to achieve significance at the 12 month follow-up (7 vs. 11; p=0.1).
- Statistically significant improvements in PRWE were similarly observed in the volar-plated group over the external fixation group at the 3 (12 vs. 31; p<0.001) and 6 month follow-ups (9 vs. 17; p=0.02). This result failed to achieve significance at the 12 month follow-up (11 vs. 15; p=0.3).
- Grip strength and range of motion (extension, supination, and pronation) were statistically superior in the volar plated group versus the external fixation group at the 3 month and 6 month follow-up points (p<0.05)
- The volar group demonstrated significantly reduced axial shortening (at all time points; p<0.001) and dorsal angulation (at 12 months; p=0.05) of the radius following radiographic analysis.
- 12 patients in the external fixation group and 7 patients in the volar locked plate group experienced complications over 1 year.
Che cosa devo ricordare di più?
The volar plated group demonstrated superior patient perceived functional outcomes (DASH) and patient related wrist evaluation (PRWE) scores during early follow-up (up to 6 months); however, these benefits diminished in comparison to external fixation over time (12 months). Similar trends were observed for grip strength, whereas extension, supination, and pronation, and reduction in axial shortening remained significantly better at all follow-up periods.
Come influenzerà l'assistenza ai miei pazienti?
The authors conclude that volar plating should be preferentially implemented for patients seeking rapid recovery of wrist function. The use of an external method is still applicable and offers advantages, such as cost and invasiveness. However, the possibility of late future complications with plating needs to be investigated, and the small sample size of the study should be taken into consideration.
DISCLAIMER
Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.