FOOT & ANKLE
Unstable ankle fractures: Better clinical results with metal versus biodegradable implants .
High Impact
Este estudo foi identificado como tendo um impacto potencialmente elevado. A métrica de Alto Impacto da OE, baseada em IA, estima a influência que um artigo poderá ter, integrando sinais da revista em que foi publicado e do conteúdo científico do próprio artigo. Desenvolvido com recurso ao mais avançado processamento de linguagem natural, o modelo High Impact da OE prevê com maior precisão o desempenho futuro de um estudo em termos de citações do que o fator de impacto da revista por si só. Isto permite o reconhecimento precoce de investigação clinicamente significativa e ajuda os leitores a concentrarem-se nos artigos com maior probabilidade de moldar a prática futura.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(6):38 J Bone Joint Surg Am. 2012 Nov 21;94(22):e1661-7. doi: 10.2106/JBJS.K.01221
Autores contribuintes

JH Noh YH Roh BG Yang SW Kim JS Lee MK Oh

109 patients with unstable ankle fractures, requiring surgical intervention, were included in this study to compare clinical outcomes of metal and biodegradable implant fixations. Patients who underwent fixation using a metal implant had a shorter mean operative time, required less time to bone union, and had superior American Orthopaedic Foot and Ankle Society ankle-hindfoot scale scores at 12 months. Patients in the metal implant group also had fewer non-unions when compared to the biodegradable implants; however, this difference was not significant.


Detalhes do financiamento da publicação +
Financiamento:
Non-funded
Conflitos:
None disclosed

Risco de viés

5/10

Critérios de notificação

16/20

Índice de Fragilidade

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

2/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

Due to the complexity of displaced ankle fractures surgical reduction and fixation are required to ensure the best functional recovery. Metallic implants are often used to provide adequate stability; however, metallic implants have a number of theoretical and practical disadvantages, including stress shielding and the need for possible secondary operations to remove the implant. The use of biodegradable implants, as an alternative for internal fixator for ankle fractures, was introduced in the 1980's, and the advent of new technologies have led to the development of numerous biodegradable materials - each with different characteristics. Comparisons between biodegradable implants made of polylevolactic acid and metallic implants for fixations of displaced ankle fractures have yet to be conducted using a randomized trial.

Qual era a principal questão de investigação?

Does the use of biodegradable implants, made of polylevolactic acid, provide similar clinical and functional outcomes compared to the use of metallic implants for the fixation of unstable ankle fractures, assessed over a 12 month period?

Caraterísticas do estudo +
População:
109 patients with ankle fractures requiring surgical intervention (102 available for final follow-up). Fractures included were bimalleolar and trimalleolar fractures, lateral malleolar fractures with displacement greater than 2 mm, or an isolated medial malleolar fractures with displacement of grater than 2 mm)
Intervenção:
Group 1: Patients underwent fixation using a metallic one-third tubular plate and screws (Solco Biomedical, Pyeongtaek, Gyeonggi, South Korea) (n=56)
Comparação:
Group 2: Patients underwent fixation using a biodegradable FredomPlate and screws (Inion Oy, Tampere, Finland) (n=53)
Resultados:
Outcomes included operative time, clinical and radiographic results using the Klossner classification system, the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale (AOFAS), the Short Musculoskeletal Function Assessment scoring system dysfunction index and bother index (SMFA).
Métodos:
RCT
Tempo:
Assessments were made at three, six and twelve months.
Quais foram os resultados importantes?
  • The mean operative time in group 1 (Metal) was 30.2 +/- 4.5 minutes compared to the mean operative time of 56.6 +/- 10.7 minutes (p<0.001) in group 2 (Bio)
  • There were no differences in the reduction of medial malleolus, lateral malleolus, posterior malleolus, and syndesmosis. 6 of 12 patients in group 2 (Bio) with medial malleolar fractures had a fracture gap postoperatively or during follow-up.
  • Mean time to bone union was significantly shorter in group 1 (Metal) compared to group 2 (Bio) (p=0.002): 15.8 weeks and 17.6 weeks, respectively.
  • Mean AOFAS scores were greater in group 1 (Metal): 87.5+/-3.8 compared to group 2 (Bio): 84.3+/-6.6 (p=0.004)
  • There were no differences SMFA dysfunction and bother indexes between the two groups (p=0.06 and 0.052, respectively); although, there was a trend present towards better scores in group 1 (Metal).
  • A subgroup of patients with lateral malleolar fractures did not demonstrate differences in clinical outcomes between groups.
  • There were two non-unions in group 2 (Bio) and none in group 1 (Metal) (p=0.228)
  • 18 of 53 patients in group 1(Metal) had hardware removal surgery.
De que é que me devo lembrar mais?

Fixation of unstable ankle fractures with metal implants required significantly less operative time, resulted in shorter time to radiographic union, and superior AOFAS scores;however, it is unclear if this difference in AOFAS scores was clinically relevant. The use of a metallic implant also resulted in fewer non-unions, but this difference was not significant.

Como é que isto afectará o tratamento dos meus doentes?

Metal implants provide superior outcomes for unstable ankle fractures compared to biodegradable implants made of polylevolactic acid. The use of a metal implant reduces operative time, time to union, and improves some functional measures; however, further clinical trials are necessary to support the findings of this study. Additionally, comparisons between metal implants and other biodegradable materials need to be conducted.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Close Dialog
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. Unstable ankle fractures: Better clinical results with metal versus biodegradable implants. OE Journal. 2013;1(6):38. Available from: https://myorthoevidence.com/AceReport/Show/unstable-ankle-fractures-better-clinical-results-with-metal-versus-biodegradable-implants

Copie a citação
Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Funcionalidade de Membro Premium

Para aceder a esta funcionalidade, tem de ter sessão iniciada numa conta Premium da OrthoEvidence.

Partilhe isto ACE Report