FOOT & ANKLE
Unstable ankle fractures: Better clinical results with metal versus biodegradable implants .
High Impact
Diese Studie wurde als potenziell hochrangig eingestuft. Die KI-gesteuerte High-Impact-Metrik von OE schätzt den Einfluss ein, den eine Arbeit wahrscheinlich haben wird, indem sie Signale sowohl aus der Zeitschrift, in der sie veröffentlicht wurde, als auch aus dem wissenschaftlichen Inhalt des Artikels selbst integriert. Das mit Hilfe modernster natürlicher Sprachverarbeitung entwickelte OE High Impact-Modell sagt die zukünftige Zitationsleistung einer Studie genauer voraus als der Impact-Faktor einer Zeitschrift allein. Dies ermöglicht eine frühere Erkennung von klinisch bedeutsamer Forschung und hilft den Lesern, sich auf Artikel zu konzentrieren, die die zukünftige Praxis am ehesten beeinflussen werden.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(6):38 J Bone Joint Surg Am. 2012 Nov 21;94(22):e1661-7. doi: 10.2106/JBJS.K.01221
Mitwirkende Autoren

JH Noh YH Roh BG Yang SW Kim JS Lee MK Oh

109 patients with unstable ankle fractures, requiring surgical intervention, were included in this study to compare clinical outcomes of metal and biodegradable implant fixations. Patients who underwent fixation using a metal implant had a shorter mean operative time, required less time to bone union, and had superior American Orthopaedic Foot and Ankle Society ankle-hindfoot scale scores at 12 months. Patients in the metal implant group also had fewer non-unions when compared to the biodegradable implants; however, this difference was not significant.


Details zur Finanzierung der Veröffentlichung +
Finanzierung:
Non-funded
Interessenkonflikte:
None disclosed

Risiko der Voreingenommenheit

5/10

Kriterien für die Berichterstattung

16/20

Fragilitäts-Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Ja = 1

Ungewiss = 0.5

Nicht relevant = 0

Nein = 0

Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.

2/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.

Warum wurde diese Studie jetzt benötigt?

Due to the complexity of displaced ankle fractures surgical reduction and fixation are required to ensure the best functional recovery. Metallic implants are often used to provide adequate stability; however, metallic implants have a number of theoretical and practical disadvantages, including stress shielding and the need for possible secondary operations to remove the implant. The use of biodegradable implants, as an alternative for internal fixator for ankle fractures, was introduced in the 1980's, and the advent of new technologies have led to the development of numerous biodegradable materials - each with different characteristics. Comparisons between biodegradable implants made of polylevolactic acid and metallic implants for fixations of displaced ankle fractures have yet to be conducted using a randomized trial.

Was war die wichtigste Forschungsfrage?

Does the use of biodegradable implants, made of polylevolactic acid, provide similar clinical and functional outcomes compared to the use of metallic implants for the fixation of unstable ankle fractures, assessed over a 12 month period?

Merkmale der Studie +
Bevölkerung:
109 patients with ankle fractures requiring surgical intervention (102 available for final follow-up). Fractures included were bimalleolar and trimalleolar fractures, lateral malleolar fractures with displacement greater than 2 mm, or an isolated medial malleolar fractures with displacement of grater than 2 mm)
Intervention:
Group 1: Patients underwent fixation using a metallic one-third tubular plate and screws (Solco Biomedical, Pyeongtaek, Gyeonggi, South Korea) (n=56)
Vergleich:
Group 2: Patients underwent fixation using a biodegradable FredomPlate and screws (Inion Oy, Tampere, Finland) (n=53)
Ergebnisse:
Outcomes included operative time, clinical and radiographic results using the Klossner classification system, the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale (AOFAS), the Short Musculoskeletal Function Assessment scoring system dysfunction index and bother index (SMFA).
Methoden:
RCT
Zeit:
Assessments were made at three, six and twelve months.
Was waren die wichtigsten Ergebnisse?
  • The mean operative time in group 1 (Metal) was 30.2 +/- 4.5 minutes compared to the mean operative time of 56.6 +/- 10.7 minutes (p<0.001) in group 2 (Bio)
  • There were no differences in the reduction of medial malleolus, lateral malleolus, posterior malleolus, and syndesmosis. 6 of 12 patients in group 2 (Bio) with medial malleolar fractures had a fracture gap postoperatively or during follow-up.
  • Mean time to bone union was significantly shorter in group 1 (Metal) compared to group 2 (Bio) (p=0.002): 15.8 weeks and 17.6 weeks, respectively.
  • Mean AOFAS scores were greater in group 1 (Metal): 87.5+/-3.8 compared to group 2 (Bio): 84.3+/-6.6 (p=0.004)
  • There were no differences SMFA dysfunction and bother indexes between the two groups (p=0.06 and 0.052, respectively); although, there was a trend present towards better scores in group 1 (Metal).
  • A subgroup of patients with lateral malleolar fractures did not demonstrate differences in clinical outcomes between groups.
  • There were two non-unions in group 2 (Bio) and none in group 1 (Metal) (p=0.228)
  • 18 of 53 patients in group 1(Metal) had hardware removal surgery.
Was sollte ich mir besonders merken?

Fixation of unstable ankle fractures with metal implants required significantly less operative time, resulted in shorter time to radiographic union, and superior AOFAS scores;however, it is unclear if this difference in AOFAS scores was clinically relevant. The use of a metallic implant also resulted in fewer non-unions, but this difference was not significant.

Wie wird sich dies auf die Behandlung meiner Patienten auswirken?

Metal implants provide superior outcomes for unstable ankle fractures compared to biodegradable implants made of polylevolactic acid. The use of a metal implant reduces operative time, time to union, and improves some functional measures; however, further clinical trials are necessary to support the findings of this study. Additionally, comparisons between metal implants and other biodegradable materials need to be conducted.

HAFTUNGSAUSSCHLUSS

Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.

0 von 4 monatliche KOSTENLOSE Artikel freigeschaltet
Sie haben Ihr Limit von 4 kostenlosen Artikeln in diesem Monat erreicht

Zugang zu OrthoEvidence für nur $1,99 pro Woche.

Bleiben Sie auf dem Laufenden mit den neuesten Beweisen. Jederzeit kündbar.
  • Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
  • Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
  • Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Upgrade
Close Dialog
Willkommen zurück!
Passwort vergessen?
Starten Sie Ihre KOSTENLOSE Testversion noch heute!

Ihr Konto ist verbunden mit
und umfasst den kostenlosen Zugang zu OrthoEvidence


ODER
Passwort vergessen?

ODER
Bitte überprüfen Sie Ihre E-Mail

Wenn ein Konto mit der angegebenen E-Mail-Adresse existiert, wird Ihnen eine E-Mail zum Zurücksetzen des Passworts zugesandt. Wenn Sie keine E-Mail sehen, überprüfen Sie bitte Ihren Spam- oder Junk-Ordner.

Für weitere Hilfe, kontaktieren Sie unser Support-Team.

Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Übersetzen ACE Report

OrthoEvidence nutzt einen externen Übersetzungsdienst, um Inhalte in mehreren Sprachen zugänglich zu machen. Bitte beachten Sie, dass trotz aller Bemühungen um Genauigkeit die Übersetzungen nicht immer perfekt sind.

Wie man dies zitiert ACE Report

OrthoEvidence. Unstable ankle fractures: Better clinical results with metal versus biodegradable implants. OE Journal. 2013;1(6):38. Available from: https://myorthoevidence.com/AceReport/Show/unstable-ankle-fractures-better-clinical-results-with-metal-versus-biodegradable-implants

Zitat kopieren
Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Premium-Mitglied-Funktion

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem Premium-Konto von OrthoEvidence angemeldet sein.

Teilen Sie dies ACE Report