ACE Report Cover
Trabecular metal cementless implants lead to improved knee scores following TKA
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
ARTHROPLASTY
Trabecular metal cementless implants lead to improved knee scores following TKA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(3):4 Clin Orthop Relat Res. 2013 Nov;471(11):3543-53

145 patients, between the ages of 50 and 70 years, who were admitted for primary TKA and who had moderate to severe femorotibial gonarthrosis were randomly assigned into 1 of 2 groups to compare the efficacy of a tibial component fixed by a porous tantalum system to a conventional cemented implant in terms of clinical outcomes, complications/reoperations, and radiographic results. The findings of the study indicate that at the 5 year follow-up mean KSS and mean WOMAC scores were significantly better in the cementless group when compared to the cemented group. However, no differences in frequency of complications or aseptic loosening between the two groups were found.


Dettagli sul finanziamento della pubblicazione +
Finanziamento:
Industry funded
Sponsor:
Zimmer GmbH, Winterthur, Switzerland.
Conflitti:
Other

Rischio di pregiudizio

8/10

Criteri di segnalazione

20/20

Indice di fragilità

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sì = 1

Incerto = 0,5

Non rilevante = 0

No = 0

La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.

4/4

Aleatorización

4/4

Medición de resultados

4/4

Inclusión / exclusión

4/4

Descripción de la terapia

4/4

Estadísticas

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.

Perché questo studio era necessario ora?

TKA has become a widely accepted procedure for reducing pain and improving function in patients who are experiencing physical limitations of the knee/leg. Currently, cemented TKA is the accepted standard for TKA consistently providing predictable and durable results, but certain restrictions/limitations with this procedure have led to further development of alternative techniques. Cementless fixation seeks to address the common issue of aseptic failure in patients with cemented fixation (especially in younger individuals), and increased durable biological fixation with more physiologic transfer of stress to the underlying bone. Early results with cementless implants showed promising results with achieving these goals, but a wide variety of complications and failures occurred. Tantalum, a newer biomaterial that mimics cancellous bone, may be able to overcome the issues that occurred with previous cementless implants.

Qual era la domanda di ricerca principale?

Does a tibial component fixed by a porous tantalum system achieve better clinical outcomes, fewer complications/reoperations, and improved radiographic results when compared to a conventional cemented implant?

Caratteristiche dello studio +
Population:
145 patients, between the ages of 50 and 70 years, who were admitted for primary TKA and who had moderate to severe femorotibial gonarthrosis.
Intervention:
Group 1 (Cementless): Patients in this group received an uncemented fiber metal femoral component (NexGen; Zimmer Inc.) and an uncemented Trabecular Metal monoblock tibial component. The uncemented porous tantalum tibial component was designed to have the polyethylene intruded directly into the porous tantalum tray with two Trabecular Metal hexagonal-shaped pegs on its undersurface that are press-fitted into the tibial spongosia. (Mean age: 61 +/- 5.0, n=74, 69 completed follow up, M=19/F=55)
Comparison:
Group 2 (Cemented): Patients in this group received a hybrid TKA using the same uncemented femoral component and a cemented NexGen stemmed tibial component (made of titanium alloy with a 50-mm central stem with small posterolateral flanges). Prostheses were inserted in a conventional fashion (Mean age: 60 +/- 4.6, n=71, 63 completed follow up, M=17/F=54)
Outcomes:
Primary Outcome: Knee Society Score (KSS). Secondary Outcomes: Spanish adaptation of WOMAC, complications, reoperations, and radiographic failures.
Methods:
RCT; Single Center: Double-Blinded
Time:
5 years (Outcomes were assessed preoperatively, and 15 days, 6 months, and 5 years after surgery completion).
Quali erano i risultati importanti?
  • Patients who received Cementless tibia implants exhibited improved KSS and WOMAC scores when compared to those who received the cemented implants.
  • At 5 year follow up mean KSS score was 90.4 in Group 1 and 86.5 in Group 2, a significant difference in favour of the Cementless group (p=0.02). Effect size at 95% CI for difference between the means was 3.88 +/- 2.87.
  • At 5 year follow up the WOMAC mean was 15.1 in Group 1 and 19.1 in Group 2, a significant difference in favour of the Cementless implant group (p=0.02). Effect size at 95% CI for difference between the means was -4.0 +/- 3.9.
  • Average KSS and WOMAC scores reported at 6 months and 5 years post operatively were significantly improved from preoperative levels in both groups (p<0.001 at both follow ups for both outcomes)
  • No differences between groups in terms of frequency of complications or reoperations were found by final follow up. In total 10% of Group 1 patients and 14% of Group 2 patients underwent additional procedures for complications, most of which were manipulations under anesthesia.
  • Radiographic analysis showed no difference in radiologic alignment at 5 years between the groups, and no changes in component position or osteolysis were found during the follow up period. Two patients in group 1 had progressive radiolucent lines under the anterior flange of their femoral component, but zero patients (in either group) experienced progressive radiolucent lines around the tibial component or aseptic loosening.
Che cosa devo ricordare di più?

At 5 year follow up KSS mean and mean WOMAC scores were significantly better in the cementless group when compared to the cemented group. There were no differences in frequency of complications or aseptic loosening between the two groups.

Come influenzerà l'assistenza ai miei pazienti?

The results of the study suggest that there are statistically significant differences between uncemented porous tantalum tibial components and conventional cemented tibial components in terms of knee function score, in favour of uncemented treatment. Further research determining if the difference in results outweighs the cost increase of the cementless treatment is needed.

DISCLAIMER

Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.

0 di 4 articoli mensili GRATUITI sbloccati
Ha raggiunto il suo limite di 4 visualizzazioni di articoli gratuiti questo mese

Accesso a OrthoEvidence a soli 1,99 dollari a settimana.

Rimanga in contatto con le ultime prove. Può disdire in qualsiasi momento.
  • Valutazioni critiche dei più recenti studi randomizzati controllati ad alto impatto e delle revisioni sistematiche in ortopedia.
  • Accesso ai contenuti del podcast OrthoEvidence, tra cui collaborazioni con il Journal of Bone and Joint Surgery, interviste con chirurghi di fama internazionale e tavole rotonde su notizie e argomenti ortopedici.
  • Abbonamento a The Pulse, una newsletter bisettimanale basata sulle evidenze scientifiche, progettata per aiutarla a prendere decisioni cliniche migliori.
Upgrade
Close Dialog
Bentornato!
Ha dimenticato la password?
Inizi la sua prova gratuita oggi stesso!

Il suo account sarà affiliato a
e includerà l'accesso gratuito a OrthoEvidence


O
Ha dimenticato la password?

O
Controlli la sua e-mail

Se esiste un account con l'indirizzo e-mail fornito, le verrà inviata un'e-mail di reimpostazione della password. Se non vede l'e-mail, controlli la cartella spam o posta indesiderata.

Per ulteriore assistenza, contatti il nostro team di supporto.

Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Tradurre il Rapporto ACE

OrthoEvidence utilizza un servizio di traduzione di terze parti per rendere i contenuti accessibili in più lingue. Si prega di notare che, sebbene venga fatto ogni sforzo per garantire l'accuratezza, le traduzioni potrebbero non essere sempre perfette.

Come citare questo documento ACE Report

OrthoEvidence. Trabecular metal cementless implants lead to improved knee scores following TKA. OE Journal. 2014;2(3):4. Available from: https://myorthoevidence.com/AceReport/Show/trabecular-metal-cementless-implants-lead-to-improved-knee-scores-following-tka

Copiare la citazione
Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Funzionalità per i membri Premium

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence Premium.

Condividi questo articolo ACE Report