ACE Report Cover
Trabecular metal cementless implants lead to improved knee scores following TKA
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descargar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descargar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
ARTHROPLASTY
Trabecular metal cementless implants lead to improved knee scores following TKA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(3):4 Clin Orthop Relat Res. 2013 Nov;471(11):3543-53

145 patients, between the ages of 50 and 70 years, who were admitted for primary TKA and who had moderate to severe femorotibial gonarthrosis were randomly assigned into 1 of 2 groups to compare the efficacy of a tibial component fixed by a porous tantalum system to a conventional cemented implant in terms of clinical outcomes, complications/reoperations, and radiographic results. The findings of the study indicate that at the 5 year follow-up mean KSS and mean WOMAC scores were significantly better in the cementless group when compared to the cemented group. However, no differences in frequency of complications or aseptic loosening between the two groups were found.


Detalles de la financiación de la publicación +
Financiación:
Industry funded
Patrocinador:
Zimmer GmbH, Winterthur, Switzerland.
Conflictos:
Other

Riesgo de sesgo

8/10

Criterios de información

20/20

Índice de fragilidad

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sí = 1

Incierto = 0,5

No relevante = 0

No = 0

La evaluación de los criterios de información evalúa la transparencia con la que los autores informan de las características metodológicas y del ensayo dentro de la publicación. La evaluación se divide en cinco categorías que se presentan a continuación.

4/4

Aleatorización

4/4

Medición de resultados

4/4

Inclusión / exclusión

4/4

Descripción de la terapia

4/4

Estadísticas

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

El Índice de Fragilidad es una herramienta que ayuda en la interpretación de hallazgos significativos, proporcionando una medida de fuerza para un resultado. El Índice de Fragilidad representa el número de eventos consecutivos que es necesario añadir a un resultado dicotómico para que el hallazgo deje de ser significativo. Un número pequeño representa un hallazgo más débil y un número grande un hallazgo más fuerte.

¿Por qué se necesitaba ahora este estudio?

TKA has become a widely accepted procedure for reducing pain and improving function in patients who are experiencing physical limitations of the knee/leg. Currently, cemented TKA is the accepted standard for TKA consistently providing predictable and durable results, but certain restrictions/limitations with this procedure have led to further development of alternative techniques. Cementless fixation seeks to address the common issue of aseptic failure in patients with cemented fixation (especially in younger individuals), and increased durable biological fixation with more physiologic transfer of stress to the underlying bone. Early results with cementless implants showed promising results with achieving these goals, but a wide variety of complications and failures occurred. Tantalum, a newer biomaterial that mimics cancellous bone, may be able to overcome the issues that occurred with previous cementless implants.

¿Cuál era la pregunta principal de la investigación?

Does a tibial component fixed by a porous tantalum system achieve better clinical outcomes, fewer complications/reoperations, and improved radiographic results when compared to a conventional cemented implant?

Características del estudio +
Población:
145 patients, between the ages of 50 and 70 years, who were admitted for primary TKA and who had moderate to severe femorotibial gonarthrosis.
Intervención:
Group 1 (Cementless): Patients in this group received an uncemented fiber metal femoral component (NexGen; Zimmer Inc.) and an uncemented Trabecular Metal monoblock tibial component. The uncemented porous tantalum tibial component was designed to have the polyethylene intruded directly into the porous tantalum tray with two Trabecular Metal hexagonal-shaped pegs on its undersurface that are press-fitted into the tibial spongosia. (Mean age: 61 +/- 5.0, n=74, 69 completed follow up, M=19/F=55)
Comparación:
Group 2 (Cemented): Patients in this group received a hybrid TKA using the same uncemented femoral component and a cemented NexGen stemmed tibial component (made of titanium alloy with a 50-mm central stem with small posterolateral flanges). Prostheses were inserted in a conventional fashion (Mean age: 60 +/- 4.6, n=71, 63 completed follow up, M=17/F=54)
Resultados:
Primary Outcome: Knee Society Score (KSS). Secondary Outcomes: Spanish adaptation of WOMAC, complications, reoperations, and radiographic failures.
Métodos:
RCT; Single Center: Double-Blinded
Tiempo:
5 years (Outcomes were assessed preoperatively, and 15 days, 6 months, and 5 years after surgery completion).
¿Cuáles fueron los hallazgos importantes?
  • Patients who received Cementless tibia implants exhibited improved KSS and WOMAC scores when compared to those who received the cemented implants.
  • At 5 year follow up mean KSS score was 90.4 in Group 1 and 86.5 in Group 2, a significant difference in favour of the Cementless group (p=0.02). Effect size at 95% CI for difference between the means was 3.88 +/- 2.87.
  • At 5 year follow up the WOMAC mean was 15.1 in Group 1 and 19.1 in Group 2, a significant difference in favour of the Cementless implant group (p=0.02). Effect size at 95% CI for difference between the means was -4.0 +/- 3.9.
  • Average KSS and WOMAC scores reported at 6 months and 5 years post operatively were significantly improved from preoperative levels in both groups (p<0.001 at both follow ups for both outcomes)
  • No differences between groups in terms of frequency of complications or reoperations were found by final follow up. In total 10% of Group 1 patients and 14% of Group 2 patients underwent additional procedures for complications, most of which were manipulations under anesthesia.
  • Radiographic analysis showed no difference in radiologic alignment at 5 years between the groups, and no changes in component position or osteolysis were found during the follow up period. Two patients in group 1 had progressive radiolucent lines under the anterior flange of their femoral component, but zero patients (in either group) experienced progressive radiolucent lines around the tibial component or aseptic loosening.
¿Qué es lo que más debo recordar?

At 5 year follow up KSS mean and mean WOMAC scores were significantly better in the cementless group when compared to the cemented group. There were no differences in frequency of complications or aseptic loosening between the two groups.

¿Cómo afectará esto al cuidado de mis pacientes?

The results of the study suggest that there are statistically significant differences between uncemented porous tantalum tibial components and conventional cemented tibial components in terms of knee function score, in favour of uncemented treatment. Further research determining if the difference in results outweighs the cost increase of the cementless treatment is needed.

DESCARGO DE RESPONSABILIDAD

El contenido de esta página tiene únicamente fines informativos y no pretende sustituir el consejo, diagnóstico o tratamiento médico profesional. Si necesita tratamiento médico, busque siempre el consejo de su médico o acuda al servicio de urgencias más cercano. Las opiniones, creencias y puntos de vista expresados por las personas sobre el contenido que se encuentra en esta página no reflejan las opiniones, creencias y puntos de vista de OrthoEvidence.

0 de 4 artículos mensuales GRATIS desbloqueados
Ha alcanzado su límite de vistas de 4 artículos gratuitos este mes

Acceda a OrtoEvidencia por tan sólo 1,99 $ a la semana.

Manténgase conectado con las últimas pruebas. Cancele en cualquier momento.
  • Valoraciones críticas de los últimos ensayos controlados aleatorizados de gran impacto y revisiones sistemáticas en ortopedia
  • Acceso al contenido del podcast OrthoEvidence, que incluye colaboraciones con el Journal of Bone and Joint Surgery, entrevistas con cirujanos reconocidos internacionalmente y mesas redondas sobre noticias y temas ortopédicos
  • Suscripción a The Pulse, un boletín quincenal basado en la evidencia y diseñado para ayudarle a tomar mejores decisiones clínicas
Upgrade
Close Dialog
Bienvenido
¿Ha olvidado su contraseña?
Comience hoy mismo su prueba GRATUITA

Su cuenta estará afiliada a
e incluye acceso gratuito a OrthoEvidence


O
¿Olvidó su contraseña?

O
Compruebe su correo electrónico

Si existe una cuenta con la dirección de correo electrónico proporcionada, se le enviará un correo electrónico para restablecer la contraseña. Si no ve el correo electrónico, compruebe su carpeta de correo no deseado o spam.

Si necesita más ayuda póngase en contacto con nuestro equipo de asistencia.

Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Traducir Informe ACE

OrthoEvidence utiliza un servicio de traducción de terceros para que el contenido sea accesible en varios idiomas. Tenga en cuenta que, aunque se hace todo lo posible para garantizar la exactitud, las traducciones no siempre son perfectas.

Cómo citar esto ACE Report

OrthoEvidence. Trabecular metal cementless implants lead to improved knee scores following TKA. OE Journal. 2014;2(3):4. Available from: https://myorthoevidence.com/AceReport/Show/trabecular-metal-cementless-implants-lead-to-improved-knee-scores-following-tka

Copiar cita
Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Función de miembro Premium

Para acceder a esta función, debe iniciar sesión en una cuenta Premium de OrthoEvidence.

Compartir ACE Report