ARTHROPLASTY
Trabecular metal cementless implants lead to improved knee scores following TKA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(3):4 Clin Orthop Relat Res. 2013 Nov;471(11):3543-53

145 patients, between the ages of 50 and 70 years, who were admitted for primary TKA and who had moderate to severe femorotibial gonarthrosis were randomly assigned into 1 of 2 groups to compare the efficacy of a tibial component fixed by a porous tantalum system to a conventional cemented implant in terms of clinical outcomes, complications/reoperations, and radiographic results. The findings of the study indicate that at the 5 year follow-up mean KSS and mean WOMAC scores were significantly better in the cementless group when compared to the cemented group. However, no differences in frequency of complications or aseptic loosening between the two groups were found.


Details zur Finanzierung der Veröffentlichung +
Finanzierung:
Industry funded
Sponsor:
Zimmer GmbH, Winterthur, Switzerland.
Interessenkonflikte:
Other

Risiko der Voreingenommenheit

8/10

Kriterien für die Berichterstattung

20/20

Fragilitäts-Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Ja = 1

Ungewiss = 0.5

Nicht relevant = 0

Nein = 0

Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.

4/4

Aleatorización

4/4

Medición de resultados

4/4

Inclusión / exclusión

4/4

Descripción de la terapia

4/4

Estadísticas

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.

Warum wurde diese Studie jetzt benötigt?

TKA has become a widely accepted procedure for reducing pain and improving function in patients who are experiencing physical limitations of the knee/leg. Currently, cemented TKA is the accepted standard for TKA consistently providing predictable and durable results, but certain restrictions/limitations with this procedure have led to further development of alternative techniques. Cementless fixation seeks to address the common issue of aseptic failure in patients with cemented fixation (especially in younger individuals), and increased durable biological fixation with more physiologic transfer of stress to the underlying bone. Early results with cementless implants showed promising results with achieving these goals, but a wide variety of complications and failures occurred. Tantalum, a newer biomaterial that mimics cancellous bone, may be able to overcome the issues that occurred with previous cementless implants.

Was war die wichtigste Forschungsfrage?

Does a tibial component fixed by a porous tantalum system achieve better clinical outcomes, fewer complications/reoperations, and improved radiographic results when compared to a conventional cemented implant?

Merkmale der Studie +
Bevölkerung:
145 patients, between the ages of 50 and 70 years, who were admitted for primary TKA and who had moderate to severe femorotibial gonarthrosis.
Intervention:
Group 1 (Cementless): Patients in this group received an uncemented fiber metal femoral component (NexGen; Zimmer Inc.) and an uncemented Trabecular Metal monoblock tibial component. The uncemented porous tantalum tibial component was designed to have the polyethylene intruded directly into the porous tantalum tray with two Trabecular Metal hexagonal-shaped pegs on its undersurface that are press-fitted into the tibial spongosia. (Mean age: 61 +/- 5.0, n=74, 69 completed follow up, M=19/F=55)
Vergleich:
Group 2 (Cemented): Patients in this group received a hybrid TKA using the same uncemented femoral component and a cemented NexGen stemmed tibial component (made of titanium alloy with a 50-mm central stem with small posterolateral flanges). Prostheses were inserted in a conventional fashion (Mean age: 60 +/- 4.6, n=71, 63 completed follow up, M=17/F=54)
Ergebnisse:
Primary Outcome: Knee Society Score (KSS). Secondary Outcomes: Spanish adaptation of WOMAC, complications, reoperations, and radiographic failures.
Methoden:
RCT; Single Center: Double-Blinded
Zeit:
5 years (Outcomes were assessed preoperatively, and 15 days, 6 months, and 5 years after surgery completion).
Was waren die wichtigsten Ergebnisse?
  • Patients who received Cementless tibia implants exhibited improved KSS and WOMAC scores when compared to those who received the cemented implants.
  • At 5 year follow up mean KSS score was 90.4 in Group 1 and 86.5 in Group 2, a significant difference in favour of the Cementless group (p=0.02). Effect size at 95% CI for difference between the means was 3.88 +/- 2.87.
  • At 5 year follow up the WOMAC mean was 15.1 in Group 1 and 19.1 in Group 2, a significant difference in favour of the Cementless implant group (p=0.02). Effect size at 95% CI for difference between the means was -4.0 +/- 3.9.
  • Average KSS and WOMAC scores reported at 6 months and 5 years post operatively were significantly improved from preoperative levels in both groups (p<0.001 at both follow ups for both outcomes)
  • No differences between groups in terms of frequency of complications or reoperations were found by final follow up. In total 10% of Group 1 patients and 14% of Group 2 patients underwent additional procedures for complications, most of which were manipulations under anesthesia.
  • Radiographic analysis showed no difference in radiologic alignment at 5 years between the groups, and no changes in component position or osteolysis were found during the follow up period. Two patients in group 1 had progressive radiolucent lines under the anterior flange of their femoral component, but zero patients (in either group) experienced progressive radiolucent lines around the tibial component or aseptic loosening.
Was sollte ich mir besonders merken?

At 5 year follow up KSS mean and mean WOMAC scores were significantly better in the cementless group when compared to the cemented group. There were no differences in frequency of complications or aseptic loosening between the two groups.

Wie wird sich dies auf die Behandlung meiner Patienten auswirken?

The results of the study suggest that there are statistically significant differences between uncemented porous tantalum tibial components and conventional cemented tibial components in terms of knee function score, in favour of uncemented treatment. Further research determining if the difference in results outweighs the cost increase of the cementless treatment is needed.

HAFTUNGSAUSSCHLUSS

Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.

0 von 4 monatliche KOSTENLOSE Artikel freigeschaltet
Sie haben Ihr Limit von 4 kostenlosen Artikeln in diesem Monat erreicht

Zugang zu OrthoEvidence für nur $1,99 pro Woche.

Bleiben Sie auf dem Laufenden mit den neuesten Beweisen. Jederzeit kündbar.
  • Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
  • Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
  • Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Upgrade
Close Dialog
Willkommen zurück!
Passwort vergessen?
Starten Sie Ihre KOSTENLOSE Testversion noch heute!

Ihr Konto ist verbunden mit
und umfasst den kostenlosen Zugang zu OrthoEvidence


ODER
Passwort vergessen?

ODER
Bitte überprüfen Sie Ihre E-Mail

Wenn ein Konto mit der angegebenen E-Mail-Adresse existiert, wird Ihnen eine E-Mail zum Zurücksetzen des Passworts zugesandt. Wenn Sie keine E-Mail sehen, überprüfen Sie bitte Ihren Spam- oder Junk-Ordner.

Für weitere Hilfe, kontaktieren Sie unser Support-Team.

Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Übersetzen ACE Report

OrthoEvidence nutzt einen externen Übersetzungsdienst, um Inhalte in mehreren Sprachen zugänglich zu machen. Bitte beachten Sie, dass trotz aller Bemühungen um Genauigkeit die Übersetzungen nicht immer perfekt sind.

Wie man dies zitiert ACE Report

OrthoEvidence. Trabecular metal cementless implants lead to improved knee scores following TKA. OE Journal. 2014;2(3):4. Available from: https://myorthoevidence.com/AceReport/Show/trabecular-metal-cementless-implants-lead-to-improved-knee-scores-following-tka

Zitat kopieren
Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Premium-Mitglied-Funktion

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem Premium-Konto von OrthoEvidence angemeldet sein.

Teilen Sie dies ACE Report