ARTHROPLASTY

The effect of different hydroxyapatite application techniques on femoral stem stability .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2016;4(13):8 Acta Orthop. 2016 Feb;87(1):42-7.

Autores contribuintes

B Flatoy SM Rohrl B Boe L Nordsletten

50 patients (55 hips) scheduled for primary total hip arthroplasty were randomized to receive implants with hydroxyapatite applied either via electrochemical deposition or plasma-spray. The purpose of this study was to determine whether differences exists between methods with respect to bone density loss, aseptic loosening, periprosthetic migration and functional scores when evaluated up to 5 years post-surgery. Results demonstrated that although patients in the plasma-spray group demonstrated significantly less loss in bone mineral density and decreased retroversion rates at certain time-points, the two methods of hydroxyapatite application were deemed to be clinically comparable.


Detalhes do financiamento da publicação +
Financiamento:
Industry funded
Patrocinador:
Biomet Europe
Conflitos:
None disclosed

Risco de viés

6,5/10

Critérios de notificação

17/20

Índice de Fragilidade

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

2/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

Fixation of implants following total hip arthroplasty is critically dependent on successful integration between prosthetic and natural surfaces. As such, osseointegrative techniques have been developed in order to ensure implant stability; this includes the application of naturally occurring and bone formation inducing biomaterial such as hydroxyapatite. Hydroxyapatite is normally applied via plasma spray or by electrochemical deposition for the purpose of reducing aseptic loosening and bone resorption, however, there is a lack of clinical evaluation that directly compares the two methods. Thus, the current study was conducted.

Qual era a principal questão de investigação?

For patients scheduled for total hip arthroplasty, did either hydroxyapatite application accomplished by electrochemical disposition or plasma-spray result in significantly reduced periprosthetic migration and bone resorption, when assessed up to 5 years postoperatively?

Caraterísticas do estudo +
População:
50 patients (55 hips) aged less than 80 years and scheduled for primary total hip arthroplasty were included in this study. Peri-prosthetic stems were implanted by a modified Hardinge approach in addition to a 28-mm CoCr femoral head and a SHP cemented polyethylene cup (Biomet, Warsaw, IN) with bone cement. Electrochemically deposited (BM) or plasma-sprayed (HA) hydroxyapatite was applied to Taperloc cementless stems intraoperatively (Biomet UK Healthcare, Bridgend, UK) (mean age= 63[28-81], M=19/F=31).
Intervenção:
BM group: hydroxyapatite was applied through electrochemical deposition, resulting in a thickness of 5 micrometers and a crystallinity of 70-72% (n=31, 28 completed follow-up).
Comparação:
HA group: hydroxyapatite was applied through plasma-spray to a thickness of 50 micrometers and a crystallinity of 62% (n=24, 20 completed follow-up).
Resultados:
The primary outcome measure were the periprosthetic changes in bone mineral density (BMD) when immediate postoperative measurements were compared to successive evaluations. Secondary outcomes measures included stem migration measured by radiostereometric analysis (RSA), aseptic loosening (measured by radiograph), the Harris Hip Score (HHS), and the Oxford Hip Score (OHS).
Métodos:
RCT: multi-centre
Tempo:
Bone densitometry (DXA) scans and RSA scans were performed 3, 6, 12, 24, and 60 months post-surgery. Standard radiographs measuring aseptic loosening were performed up to 5 years post-surgery.
Quais foram os resultados importantes?
  • Bone mineral density (BMD) was reported to have declined in all Gruen zones for all patients, with the majority of this bone loss occurring within the first year. After two years, bone loss ranged from 8-14% in zones 2 to 6 and ~30% in zone 7.
  • The greatest loss in bone remodeling rate was seen in zone 7 (34% for BM group vs. 31% for HA group) and in zone 1 (20% for BM group vs. 25% for HA group).
  • BMD for patients in the BM group decreased by a rate of 0.11%/month (95% CI -0.19 to -0.04), compared to a rate of 0.01%/month (95% CI -0.08 to 0.1) in the HA group; this difference was statistically significant (p=0.04), however, it was determined to be clinically irrelevant.
  • Stem subsidence/migration during the first 3 months occurred at comparable rates when study groups were compared (p=0.6); subsidence rates were minuscule when measured after the 3-month time point, with comparable rates once again demonstrated between study groups (p=0.4).
  • Rates of retroversion were significantly higher in the first three months for patients in the BM group when compared to the HA group (0.17 degrees/month [0.11-0.23] vs. 0.06 degrees/month [-0.01-0.12] respectively, p=0.006); after the 3-month time point, retroversion rates remained stable and were comparable between study groups (p=0.3).
  • HHS and OHS scores were comparable between study groups after 5 postoperative years.
De que é que me devo lembrar mais?

Bone mineral density loss and retroversion rates in THA patients significantly differed between electrochemical deposition and plasma-spray groups (significance was observed at 3 months for the latter), with less severe rates observed in patients who receive hydroxyapatite application through plasma-spray. However, as all patients and prostheses remained stable throughout the study period the significance was deemed to be clinically insignificant. All other outcomes were comparable when measured at all follow-up points.

Como é que isto afectará o tratamento dos meus doentes?

The results of this study demonstrated that there were no clinically significant differences between the two methods of hydroxyapatite application five years following total hip arthroplasty. While this study demonstrates no differences between hydroxyapatite application techniques, questions still remain regarding the use of hydroxyapatite and if it provides any clinically relevant advantages.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Close Dialog
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. The effect of different hydroxyapatite application techniques on femoral stem stability. OE Journal. 2016;4(13):8. Available from: https://myorthoevidence.com/AceReport/Show/the-effect-of-different-hydroxyapatite-application-techniques-on-femoral-stem-stability

Copie a citação
Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Funcionalidade de Membro Premium

Para aceder a esta funcionalidade, tem de ter sessão iniciada numa conta Premium da OrthoEvidence.

Partilhe isto ACE Report