ARTHROPLASTY
The effect of different hydroxyapatite application techniques on femoral stem stability .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2016;4(13):8 Acta Orthop. 2016 Feb;87(1):42-7.
Autori che hanno contribuito

B Flatoy SM Rohrl B Boe L Nordsletten

50 patients (55 hips) scheduled for primary total hip arthroplasty were randomized to receive implants with hydroxyapatite applied either via electrochemical deposition or plasma-spray. The purpose of this study was to determine whether differences exists between methods with respect to bone density loss, aseptic loosening, periprosthetic migration and functional scores when evaluated up to 5 years post-surgery. Results demonstrated that although patients in the plasma-spray group demonstrated significantly less loss in bone mineral density and decreased retroversion rates at certain time-points, the two methods of hydroxyapatite application were deemed to be clinically comparable.


Dettagli sul finanziamento della pubblicazione +
Finanziamento:
Industry funded
Sponsor:
Biomet Europe
Conflicts:
None disclosed

Rischio di pregiudizio

6,5/10

Criteri di segnalazione

17/20

Indice di fragilità

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sì = 1

Incerto = 0,5

Non rilevante = 0

No = 0

La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.

2/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.

Perché questo studio era necessario ora?

Fixation of implants following total hip arthroplasty is critically dependent on successful integration between prosthetic and natural surfaces. As such, osseointegrative techniques have been developed in order to ensure implant stability; this includes the application of naturally occurring and bone formation inducing biomaterial such as hydroxyapatite. Hydroxyapatite is normally applied via plasma spray or by electrochemical deposition for the purpose of reducing aseptic loosening and bone resorption, however, there is a lack of clinical evaluation that directly compares the two methods. Thus, the current study was conducted.

Qual era la domanda di ricerca principale?

For patients scheduled for total hip arthroplasty, did either hydroxyapatite application accomplished by electrochemical disposition or plasma-spray result in significantly reduced periprosthetic migration and bone resorption, when assessed up to 5 years postoperatively?

Caratteristiche dello studio +
Population:
50 patients (55 hips) aged less than 80 years and scheduled for primary total hip arthroplasty were included in this study. Peri-prosthetic stems were implanted by a modified Hardinge approach in addition to a 28-mm CoCr femoral head and a SHP cemented polyethylene cup (Biomet, Warsaw, IN) with bone cement. Electrochemically deposited (BM) or plasma-sprayed (HA) hydroxyapatite was applied to Taperloc cementless stems intraoperatively (Biomet UK Healthcare, Bridgend, UK) (mean age= 63[28-81], M=19/F=31).
Intervention:
BM group: hydroxyapatite was applied through electrochemical deposition, resulting in a thickness of 5 micrometers and a crystallinity of 70-72% (n=31, 28 completed follow-up).
Comparison:
HA group: hydroxyapatite was applied through plasma-spray to a thickness of 50 micrometers and a crystallinity of 62% (n=24, 20 completed follow-up).
Outcomes:
The primary outcome measure were the periprosthetic changes in bone mineral density (BMD) when immediate postoperative measurements were compared to successive evaluations. Secondary outcomes measures included stem migration measured by radiostereometric analysis (RSA), aseptic loosening (measured by radiograph), the Harris Hip Score (HHS), and the Oxford Hip Score (OHS).
Methods:
RCT: multi-centre
Time:
Bone densitometry (DXA) scans and RSA scans were performed 3, 6, 12, 24, and 60 months post-surgery. Standard radiographs measuring aseptic loosening were performed up to 5 years post-surgery.
Quali erano i risultati importanti?
  • Bone mineral density (BMD) was reported to have declined in all Gruen zones for all patients, with the majority of this bone loss occurring within the first year. After two years, bone loss ranged from 8-14% in zones 2 to 6 and ~30% in zone 7.
  • The greatest loss in bone remodeling rate was seen in zone 7 (34% for BM group vs. 31% for HA group) and in zone 1 (20% for BM group vs. 25% for HA group).
  • BMD for patients in the BM group decreased by a rate of 0.11%/month (95% CI -0.19 to -0.04), compared to a rate of 0.01%/month (95% CI -0.08 to 0.1) in the HA group; this difference was statistically significant (p=0.04), however, it was determined to be clinically irrelevant.
  • Stem subsidence/migration during the first 3 months occurred at comparable rates when study groups were compared (p=0.6); subsidence rates were minuscule when measured after the 3-month time point, with comparable rates once again demonstrated between study groups (p=0.4).
  • Rates of retroversion were significantly higher in the first three months for patients in the BM group when compared to the HA group (0.17 degrees/month [0.11-0.23] vs. 0.06 degrees/month [-0.01-0.12] respectively, p=0.006); after the 3-month time point, retroversion rates remained stable and were comparable between study groups (p=0.3).
  • HHS and OHS scores were comparable between study groups after 5 postoperative years.
Che cosa devo ricordare di più?

Bone mineral density loss and retroversion rates in THA patients significantly differed between electrochemical deposition and plasma-spray groups (significance was observed at 3 months for the latter), with less severe rates observed in patients who receive hydroxyapatite application through plasma-spray. However, as all patients and prostheses remained stable throughout the study period the significance was deemed to be clinically insignificant. All other outcomes were comparable when measured at all follow-up points.

Come influenzerà l'assistenza ai miei pazienti?

The results of this study demonstrated that there were no clinically significant differences between the two methods of hydroxyapatite application five years following total hip arthroplasty. While this study demonstrates no differences between hydroxyapatite application techniques, questions still remain regarding the use of hydroxyapatite and if it provides any clinically relevant advantages.

DISCLAIMER

Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.

0 di 4 articoli mensili GRATUITI sbloccati
Ha raggiunto il suo limite di 4 visualizzazioni di articoli gratuiti questo mese

Accesso a OrthoEvidence a soli 1,99 dollari a settimana.

Rimanga in contatto con le ultime prove. Può disdire in qualsiasi momento.
  • Valutazioni critiche dei più recenti studi randomizzati controllati ad alto impatto e delle revisioni sistematiche in ortopedia.
  • Accesso ai contenuti del podcast OrthoEvidence, tra cui collaborazioni con il Journal of Bone and Joint Surgery, interviste con chirurghi di fama internazionale e tavole rotonde su notizie e argomenti ortopedici.
  • Abbonamento a The Pulse, una newsletter bisettimanale basata sulle evidenze scientifiche, progettata per aiutarla a prendere decisioni cliniche migliori.
Upgrade
Bentornato!
Ha dimenticato la password?
Inizi la sua prova gratuita oggi stesso!

Il suo account sarà affiliato a
e includerà l'accesso gratuito a OrthoEvidence


O
Ha dimenticato la password?

O
Controlli la sua e-mail

Se esiste un account con l'indirizzo e-mail fornito, le verrà inviata un'e-mail di reimpostazione della password. Se non vede l'e-mail, controlli la cartella spam o posta indesiderata.

Per ulteriore assistenza, contatti il nostro team di supporto.

Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Tradurre il Rapporto ACE

OrthoEvidence utilizza un servizio di traduzione di terze parti per rendere i contenuti accessibili in più lingue. Si prega di notare che, sebbene venga fatto ogni sforzo per garantire l'accuratezza, le traduzioni potrebbero non essere sempre perfette.

Come citare questo documento ACE Report

OrthoEvidence. The effect of different hydroxyapatite application techniques on femoral stem stability. OE Journal. 2016;4(13):8. Available from: https://myorthoevidence.com/AceReport/Show/the-effect-of-different-hydroxyapatite-application-techniques-on-femoral-stem-stability

Copiare la citazione
Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Funzionalità per i membri Premium

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence Premium.

Condividi questo articolo ACE Report