ACE Report Cover
THA: Stem migration and bone loss similar in cementless vs. cemented femoral components
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り

ARTHROPLASTY

Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry: 43 hips followed for 2 years in a prospective trial

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(6):26 Acta Orthop. 2012 Dec;83(6):592-8. doi: 10.3109/17453674.2012.742393. Epub 2012 Nov 1

51 patients, including 52 hips, undergoing treatment for osteoarthritis were randomized to receive either reverse hybrid (cemented polyethylene cup with cementless femoral stem) or conventional cemented total hip replacement (both components cemented) to determine if there was a difference in outcome between the techniques. Clinical outcome, wear, component migration and bone remodeling were recorded over 2 years postoperatively. The results showed that there were no major differences between the two procedures. This study indicated that the reverse hybrid procedure does not provide improved outcomes when compared to the conventional cemented method in total hip replacement.


出版資金提供の詳細 +
資金提供:
Not Reported
コンフリクト:
None disclosed

バイアスのリスク

6.5/10

報告基準

14/20

脆弱性指数

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

はい = 1

不確実=0.5

無関係 = 0

いいえ = 0

報告基準評価では、著者が出版物内で試験の方法論的特徴や試験特性を報告する際の透明性を評価します。評価は以下の5つのカテゴリーに分類されます。

1/4

Aleatorización

3/4

Medidas de resultado

2/4

Inclusión/Exclusión

4/4

Descripción del tratamiento

4/4

Estadística

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Fragility Indexは、重要な所見の解釈を助けるツールで、結果の強さの尺度を提供します。Fragility Indexは、その所見が有意でなくなるために、二項対立の結果に追加する必要がある連続した事象の数を表します。数値が小さいほど弱い所見を表し、数値が大きいほど強い所見を表します。

なぜ今この研究が必要なのですか?

The Swedish Hip Arthroplasty and Norwegian Arthroplasty Registers have shown increased use of reverse hybrid technique (cemented polyethylene cup with cementless femoral stem) in total hip replacement. This is in part is due to the observed improvement in survivability of the cementless stems with respect to component loosening. However, there has been concern regarding polyethylene wear induced by hydroxyapatite (HA) in HA-coated implants, commonly seen in reverse hybrid total hip replacements. Also, there has not been a study conducted that has shown that the reverse hybrid technique is superior to conventional cemented total hip replacement, indicating the need for this study.

主な研究課題は何ですか?

Does the reverse hybrid total hip replacement technique provide superiority to conventional cemented total hip replacement with respect to clinical results, wear, remodeling of the bone, component migration, or component loosening after 2 years?

研究の特徴 +
人口:
51 patients (52 hips) with osteoarthritis undergoing total hip replacement with cemented all-polyethylene cup. (n=43 total hips from 42 patients completed follow-up)
介入:
Reverse Hybrid Group: Patients underwent reverse hybrid total hip replacement with a cementless femoral stem, including proximal HA coating on top of the metal coating, tantalum balls attached at the tip, calcar region, and neck for radiostereometry analysis (RSA), and a 28-mm cobalt chrome head. (n=19 hips from 19 patients)
比較:
Cemented Group: Patients underwent conventional cemented total hip replacement with cemented femoral stem, with tantalum markers attached to the tip, calcar region and head (for RSA), and a 28-mm cobalt chrome head. A polyethylene distal cement restrictor was used and cement was pressurized prior to prostheses insertion. (n=24 hips from 23 patients)
アウトカム:
Clinical outcomes were measured using Harris hip and Oxford hip scores for function and pain. Component wear and migration/rotation were evaluated using RSA. Bone remodeling and bone loss as a change in bone mineral density (BMD) were measured using dual-energy X-ray absorptiometry. Component loosening was analyzed via lucency in radiographs.
方法:
RCT, Single-centre
時間:
RSA and BMD follow-up was conducted at 6 months, 1 and 2 years postoperatively. Follow-up of clinical outcomes (Harris and Oxford hip scores) and radiographic analysis were conducted at 2 years postoperatively.

重要な知見は?

  • Similar improvements in Harris hip and Oxford hip scores were observed in both groups.
  • There were no significant differences observed between groups in the amount of wear in the x- (p=0.9), y- (p=0.9), and z-axes (p=0.08), and the vectorial resultant 3D wear (p=0.7).
  • Cup and stem component migration in any direction (x-, y-, or z-axes) were observed to not significantly differ between groups.
  • Rotation of stem component did not significantly differ between groups. Rotation of cup component in the y- and z-axes was not significantly different between groups. Rotation of the cup component in the x-axis was -0.24 degrees (95%CI -0.55 to 0.07) in the RH group and 0.13 degrees (95%CI -0.08 to 0.34) and in the cemented group, resulting in significant difference (p=0.03).
  • Bone remodeling around the cup was found to be similar between groups.
  • Significant bone loss in Gruen Zone 1 of the femur was observed in the RH group (18%, 95%CI 11-24%) when compared to the cemented group (1.4%, 95%CI -3.2-5.9%) (p<0.001). Bone loss in remaining Gruen zones (2-7) was not significant between groups.
  • There were no significant differences between groups for incidence of component loosening (p>0.05).
最も覚えておくべきことは?

The use of a cementless stem in total hip replacement provided similar results to a cemented stem with regards to Harris hip and Oxford hip scores, wear, component migration/rotation, bone remodelling, and bone loss after 2 years. Although significantly higher bone loss in Gruen Zone 1 was associated with the cementless stems, it is unlikely that it is an important clinical finding due to the long-term survivability of the cementless stems.

それが私の患者ケアにどのように影響するか?

There are no major differences between a cementless and a cemented femoral stem in total hip arthroplasty after 2 years. An extended study with a longer follow-up period is necessary to investigate any differences that may exist between the two techniques.

免責事項

このページに記載されている内容は、情報提供のみを目的としたものであり、専門的な医療アドバイス、診断、治療の代わりとなるものではありません。治療が必要な場合は、必ず医師の診断を仰ぐか、最寄りの救急外来を受診してください。このページに記載されている内容に関して個人が表明した意見、信念、見解は、OrthoEvidenceの意見、信念、見解を反映するものではありません。

0の4 月間無料記事のロック解除
今月の無料記事閲覧数が4件に達しました。

週1.99ドルからOrthoEvidenceにアクセスできます。

最新のエビデンスにアクセスしてください。いつでもキャンセルできます。
  • 整形外科における最新のインパクトのあるランダム化比較試験とシステマティックレビューの批判的評価
  • Journal of Bone and Joint Surgeryとのコラボレーション、国際的に著名な外科医へのインタビュー、整形外科ニュースやトピックに関する座談会など、OrthoEvidenceポッドキャストコンテンツへのアクセス
  • 週2回発行されるエビデンスに基づくニュースレター、The Pulseの購読。
Upgrade
Close Dialog
おかえりなさい
パスワードをお忘れですか?
今すぐ無料トライアルを開始

あなたのアカウントは
OrthoEvidenceへの無料アクセスが含まれます。


または
パスワードをお忘れですか?

または
Eメールをご確認ください

入力されたメールアドレスにアカウントが存在する場合、パスワードリセットのメールが送信されます。メールが届かない場合は、迷惑メールフォルダをご確認ください。

その他のサポート サポートチームまでご連絡ください。.

この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

ACEレポートを翻訳

OrthoEvidenceは、多言語でコンテンツにアクセスできるようにするため、第三者の翻訳サービスを利用しています。正確性を確保するためにあらゆる努力をしていますが、翻訳が必ずしも完璧ではない可能性があることにご注意ください。

引用方法 ACE Report

OrthoEvidence. THA: Stem migration and bone loss similar in cementless vs. cemented femoral components. OE Journal. 2013;1(6):26. Available from: https://myorthoevidence.com/AceReport/Show/tha-stem-migration-and-bone-loss-similar-in-cementless-vs-cemented-femoral-components

引用のコピー
この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

プレミアム会員機能

この機能にアクセスするには、OrthoEvidenceのプレミアムアカウントにログインする必要があります。

共有 ACE Report