ARTHROPLASTY
THA: No difference between low-profile cup and Standard cup in terms of migration and wear .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(11):93 Acta Orthop. 2007 Aug;78(4):479-84
Autores contribuintes

L Palm J Olofsson SE Astrom I Ivarsson

60 patients with primary osteoarthritis awaiting total hip replacement, from ages 60-80 years, were randomized to either receive THR using a low-profile Lubinus Flanged Anti-Luxation Cup (FAL) or the Lubinus Standard Eccentric cup. The results at 3 years indicated that there no difference between the Lubinus FAL cup and the Lubinus Standard cup with respect to migration and wear.


Detalhes do financiamento da publicação +
Financiamento:
Industry funded
Patrocinador:
Waldemar Link GmbH & Co
Conflicts:
None disclosed

Risco de viés

5/10

Critérios de notificação

16/20

Índice de Fragilidade

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

3/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

3/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

In total hip replacement procedures, a higher degree of containment within the bony acetabulum is achieved with low-profile acetabular components. Incidence of radioluency and wear may be reduced with the complete bony containment of cups. The low-profile design allows for greater range of free motion before femoral neck and cup impingement occurs. However, in contrast, the low-profile cups result in decreased containment of the prosthetic head within the cup therefore increasing the risk of instability or dislocation. It was reported that use of the SHP (low-profile) cup resulted in increased migration and wear, at the same time as the Lubinus Flanged Anti-Luxation Cup (FAL) was being introduced. This resulted in the need to compare this FAL low-profile cup to Standard cups, in order to examine the safety of the FAL cup and it's effects of migration and wear.

Qual era a principal questão de investigação?

How does the low-profile Lubinus Flanged Anti-Luxation Cup (FAL) compare to the Lubinous Standard Eccentric cup, in terms of the effects on migration and wear, in patients with primary osetoarthritis undergoing total hip replacement, measured at a 3 year follow up period?

Caraterísticas do estudo +
Population:
60 patients (aged 60-80 years) were included in the study. 7 patients were lost to follow up or did not meet inclusion criteria, and therefore 53 patients were available for analysis. These patients presented with primary osteoarthritis and were scheduled to undergo total hip replacement
Intervention:
FAL Group: Patients assigned to this group received THR using a low-profile Lubinus Flanged Anti-Luxation (FAL) cup (n=28 patients available for analysis; Median Age: 80 years; M/F=14/14).
Comparison:
Standard Group: Patients assigned to this group received THR using the Lubinus Standard Eccentric cup (n=25 patients available for analysis; Median Age: 69; M/F=14/11).
Outcomes:
Primary outcome measures included cup migration (maximal total point motion) and wear (total, three-dimensional vector of femoral head penetration), and were measured using radiostereometry (RSA) at 1 and 3 years. As well, clinical outcomes were measured using the WOMAC and VAS scores.
Methods:
RCT
Time:
Cup migration and wear were measured within one week post-op, 3, 6, 12 and 36 months post-operatively. Clinical outcomes measured pre-operatively and at 3, 6, and 12 months after surgery.
Quais foram os resultados importantes?
  • There was no difference in cup migration (MTPM values) between the two groups (p=0.7 at 1 year, p=0.8 at 3 years).
  • There was no difference between groups in terms of wear (p=0.9 at 1 year, p=0.7 at 3 years).
  • The clinical results (WOMAC, VAS rest, VAS activity) were excellent, with no significant differences between both groups (all p>0.05).
  • 3 cups (2 FAL, 1 Standard) reported increased proximal migration that indicated an increased risk of early loosening.
  • No correlation was observed between migration and wear.
De que é que me devo lembrar mais?

There was no significant difference between The Lubinus FAL cup and the Lubinus Standard cup, in terms of migration and wear, measured at 1 and 3 years following surgery. Clinical outcomes were equally favorable in both groups.

Como é que isto afectará o tratamento dos meus doentes?

In patients where a low-profile cup is acceptable and suitable, this study indicates that the FAL cup is safe and effective for patients undergoing total hip replacement. Further high-quality evidence with larger sample sizes is needed to evaluate the safety and efficacy of this novel implant.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. THA: No difference between low-profile cup and Standard cup in terms of migration and wear. OE Journal. 2013;1(11):93. Available from: https://myorthoevidence.com/AceReport/Show/tha-no-difference-between-low-profile-cup-and-standard-cup-in-terms-of-migration-and-wear

Copie a citação
Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Funcionalidade de Membro Premium

Para aceder a esta funcionalidade, tem de ter sessão iniciada numa conta Premium da OrthoEvidence.

Partilhe isto ACE Report