ARTHROPLASTY
THA: No difference between low-profile cup and Standard cup in terms of migration and wear .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(11):93 Acta Orthop. 2007 Aug;78(4):479-84
Autori che hanno contribuito

L Palm J Olofsson SE Astrom I Ivarsson

60 patients with primary osteoarthritis awaiting total hip replacement, from ages 60-80 years, were randomized to either receive THR using a low-profile Lubinus Flanged Anti-Luxation Cup (FAL) or the Lubinus Standard Eccentric cup. The results at 3 years indicated that there no difference between the Lubinus FAL cup and the Lubinus Standard cup with respect to migration and wear.


Dettagli sul finanziamento della pubblicazione +
Finanziamento:
Industry funded
Sponsor:
Waldemar Link GmbH & Co
Conflicts:
None disclosed

Rischio di pregiudizio

5/10

Criteri di segnalazione

16/20

Indice di fragilità

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sì = 1

Incerto = 0,5

Non rilevante = 0

No = 0

La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.

3/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

3/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.

Perché questo studio era necessario ora?

In total hip replacement procedures, a higher degree of containment within the bony acetabulum is achieved with low-profile acetabular components. Incidence of radioluency and wear may be reduced with the complete bony containment of cups. The low-profile design allows for greater range of free motion before femoral neck and cup impingement occurs. However, in contrast, the low-profile cups result in decreased containment of the prosthetic head within the cup therefore increasing the risk of instability or dislocation. It was reported that use of the SHP (low-profile) cup resulted in increased migration and wear, at the same time as the Lubinus Flanged Anti-Luxation Cup (FAL) was being introduced. This resulted in the need to compare this FAL low-profile cup to Standard cups, in order to examine the safety of the FAL cup and it's effects of migration and wear.

Qual era la domanda di ricerca principale?

How does the low-profile Lubinus Flanged Anti-Luxation Cup (FAL) compare to the Lubinous Standard Eccentric cup, in terms of the effects on migration and wear, in patients with primary osetoarthritis undergoing total hip replacement, measured at a 3 year follow up period?

Caratteristiche dello studio +
Population:
60 patients (aged 60-80 years) were included in the study. 7 patients were lost to follow up or did not meet inclusion criteria, and therefore 53 patients were available for analysis. These patients presented with primary osteoarthritis and were scheduled to undergo total hip replacement
Intervention:
FAL Group: Patients assigned to this group received THR using a low-profile Lubinus Flanged Anti-Luxation (FAL) cup (n=28 patients available for analysis; Median Age: 80 years; M/F=14/14).
Comparison:
Standard Group: Patients assigned to this group received THR using the Lubinus Standard Eccentric cup (n=25 patients available for analysis; Median Age: 69; M/F=14/11).
Outcomes:
Primary outcome measures included cup migration (maximal total point motion) and wear (total, three-dimensional vector of femoral head penetration), and were measured using radiostereometry (RSA) at 1 and 3 years. As well, clinical outcomes were measured using the WOMAC and VAS scores.
Methods:
RCT
Time:
Cup migration and wear were measured within one week post-op, 3, 6, 12 and 36 months post-operatively. Clinical outcomes measured pre-operatively and at 3, 6, and 12 months after surgery.
Quali erano i risultati importanti?
  • There was no difference in cup migration (MTPM values) between the two groups (p=0.7 at 1 year, p=0.8 at 3 years).
  • There was no difference between groups in terms of wear (p=0.9 at 1 year, p=0.7 at 3 years).
  • The clinical results (WOMAC, VAS rest, VAS activity) were excellent, with no significant differences between both groups (all p>0.05).
  • 3 cups (2 FAL, 1 Standard) reported increased proximal migration that indicated an increased risk of early loosening.
  • No correlation was observed between migration and wear.
Che cosa devo ricordare di più?

There was no significant difference between The Lubinus FAL cup and the Lubinus Standard cup, in terms of migration and wear, measured at 1 and 3 years following surgery. Clinical outcomes were equally favorable in both groups.

Come influenzerà l'assistenza ai miei pazienti?

In patients where a low-profile cup is acceptable and suitable, this study indicates that the FAL cup is safe and effective for patients undergoing total hip replacement. Further high-quality evidence with larger sample sizes is needed to evaluate the safety and efficacy of this novel implant.

DISCLAIMER

Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.

0 di 4 articoli mensili GRATUITI sbloccati
Ha raggiunto il suo limite di 4 visualizzazioni di articoli gratuiti questo mese

Accesso a OrthoEvidence a soli 1,99 dollari a settimana.

Rimanga in contatto con le ultime prove. Può disdire in qualsiasi momento.
  • Valutazioni critiche dei più recenti studi randomizzati controllati ad alto impatto e delle revisioni sistematiche in ortopedia.
  • Accesso ai contenuti del podcast OrthoEvidence, tra cui collaborazioni con il Journal of Bone and Joint Surgery, interviste con chirurghi di fama internazionale e tavole rotonde su notizie e argomenti ortopedici.
  • Abbonamento a The Pulse, una newsletter bisettimanale basata sulle evidenze scientifiche, progettata per aiutarla a prendere decisioni cliniche migliori.
Upgrade
Bentornato!
Ha dimenticato la password?
Inizi la sua prova gratuita oggi stesso!

Il suo account sarà affiliato a
e includerà l'accesso gratuito a OrthoEvidence


O
Ha dimenticato la password?

O
Controlli la sua e-mail

Se esiste un account con l'indirizzo e-mail fornito, le verrà inviata un'e-mail di reimpostazione della password. Se non vede l'e-mail, controlli la cartella spam o posta indesiderata.

Per ulteriore assistenza, contatti il nostro team di supporto.

Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Tradurre il Rapporto ACE

OrthoEvidence utilizza un servizio di traduzione di terze parti per rendere i contenuti accessibili in più lingue. Si prega di notare che, sebbene venga fatto ogni sforzo per garantire l'accuratezza, le traduzioni potrebbero non essere sempre perfette.

Come citare questo documento ACE Report

OrthoEvidence. THA: No difference between low-profile cup and Standard cup in terms of migration and wear. OE Journal. 2013;1(11):93. Available from: https://myorthoevidence.com/AceReport/Show/tha-no-difference-between-low-profile-cup-and-standard-cup-in-terms-of-migration-and-wear