ARTHROPLASTY
Rotating-platform TKA no different from fixed-bearing TKA regarding survivorship or performance: a meta-analysis
This report has been verified
by one or more authors of the
original publication.
OrthoEvidence Journal (OE Journal) - ACE Report
OE Journal. 2014;2(19):7 Clin Orthop Relat Res. 2014 Jul;472(7):2185-93. doi: 10.1007/s11999-014-3539-4. Epub 2014 Mar 4.17 studies were included in this meta-analysis (15 randomized controlled trials without blinding or prospective comparative studies and 2 retrospective comparative studies) comparing the outcomes of rotating-platform mobile-bearing prostheses to fixed bearing prostheses for total knee arthroplasty. Results from the meta-analyses of clinical scores, range of motion, radiographic outcome, rates of osteolysis, loosening, and progressive radiolucent lines, component alignment, adverse events, and revisions indicated no significant differences between rotating-platform and fixed-bearing designs, with the exception of tibial component alignment in the AP plane in favour of fixed-bearing design. However, this effect was small and clinically insignificant.
Were the search methods used to find evidence (original research) on the primary question or questions stated?
Was the search for evidence reasonably comprehensive?
Were the criteria used for deciding which studies to include in the overview reported?
Was the bias in the selection of studies avoided?
Were the criteria used for assessing the validity of the included studies reported?
Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?
Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?
Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?
Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?
How would you rate the scientific quality of this evidence?
はい = 1
不確実=0.5
無関係 = 0
いいえ = 0
報告基準評価では、著者が出版物内で試験の方法論的特徴や試験特性を報告する際の透明性を評価します。評価は以下の5つのカテゴリーに分類されます。
4/4
Introduction
4/4
Accessing Data
3/4
Analysing Data
3/4
Results
3/4
Discussion
Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65
Fragility Indexは、重要な所見の解釈を助けるツールで、結果の強さの尺度を提供します。Fragility Indexは、その所見が有意でなくなるために、二項対立の結果に追加する必要がある連続した事象の数を表します。数値が小さいほど弱い所見を表し、数値が大きいほど強い所見を表します。
なぜ今この研究が必要なのですか?
Mobile-bearing prostheses in total knee arthroplasty (TKA) are cited to improve the biomechanics of the knee and emulate its natural kinematics, thereby reducing polyethylene wear when compared to fixed bearings. Previous meta-analyses comparing mobile- to fixed-bearing TKAs often failed to distinguish between the several mobile-bearing subgroups. Several mobile-bearing designs exist, including rotating-platform, meniscal-bearing, and AP glide-and-rotation designs. As such, this meta-analysis was performed to specifically compare mobile-bearings of the rotating-platform design to fixed-bearings designs following TKA.
主な研究課題は何ですか?
How do rotating-platform mobile-bearings compare to fixed-bearings with respect to clinical performance, component alignment, incidence of adverse events, and revision rates following total knee arthroplasty?
重要な知見は?
- No significant differences were observed between groups when a meta-analysis was performed for Knee Society Function scores in 8 studies (p=0.465), Knee Society Knee scores in 10 studies (p=0.429), Hospital for Special Surgery scores in 3 studies (p=0.510), SF-12 Physical scores in 3 studies (p=0.501), and SF-12 Mental scores in 3 studies (p=0.209).
- Range of motion for flexion contracture (4 studies), extension (3 studies), flexion (9 studies), and total range of motion (8 studies) were comparable between groups (p=0884; p=0.499; p=0.058; p=0.685; respectively).
- No between group differences were observed for radiographic evaluations for palmar tilt (3 studies; p=0.670), radiolucent lines (6 studies; p=0.348), nonprogressive radiolucent lines (3 studies; p=0.903), and tibial radiolucent lines (3 studies; p=0.538).
- Rates of radiographic osteolysis (3 cases total; rotation-platform group), radiographic loosening 2 cases total; rotation-platform group), and progressive radiolucent lines (1 case in total; fixed bearing group) were not statistically different between groups.
- Tibial component alignment in the AP plane (3 studies) favoured the fixed-bearing group (standardized mean difference, 0.229; 95% CI 0.035–0.422; p=0.020), although effect size was small and not clinically important. Femoral component alignment in the AP plane and tibial component alignment in the sagittal plane were similar between groups (3 studies each; p=0.894 and p=0.379, respectively).
- Incidence of anterior knee pain (3 studies), and stiffness requiring manipulation (4 studies) were comparable between groups (p=0.821 and p=0.326 respectively).
- Number of patients requiring revision for deep infection (3 studies; 2 revisions in fixed bearing group), loosening (3 studies; 3 cases in rotating-platform group), or for any reason (9 studies; 4 revision in each group) were not significantly difference between groups.
最も覚えておくべきことは?
Results from the meta-analyses of clinical scores, range of motion, radiographic outcome, rates of osteolysis, loosening (progressive radiolucent lines), component alignment, adverse events, and revisions indicated no significant differences between rotating-platform and fixed-bearing designs, with the exception of tibial component alignment in the AP plane in favour of fixed-bearing design. However, this effect was small and clinically insignificant.
それが私の患者ケアにどのように影響するか?
The findings of this study demonstrated no clinically important differences between total knee arthroplasty performed using rotating-platform mobile-bearing prostheses versus fixed-bearing prostheses. The authors recommended that future research focus on other factors that may influence outcome.
免責事項
このページに記載されている内容は、情報提供のみを目的としたものであり、専門的な医療アドバイス、診断、治療の代わりとなるものではありません。治療が必要な場合は、必ず医師の診断を仰ぐか、最寄りの救急外来を受診してください。このページに記載されている内容に関して個人が表明した意見、信念、見解は、OrthoEvidenceの意見、信念、見解を反映するものではありません。