ACE Report Cover
Rotating-platform TKA comparable to fixed-bearing TKA
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
ARTHROPLASTY
Rotating-platform TKA comparable to fixed-bearing TKA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(19):7 Clin Orthop Relat Res. 2014 Jul;472(7):2185-93. doi: 10.1007/s11999-014-3539-4. Epub 2014 Mar 4.
المؤلفون المساهمون

JT Moskal SG Capps

17 studies were included in this meta-analysis (15 randomized controlled trials without blinding or prospective comparative studies and 2 retrospective comparative studies) comparing the outcomes of rotating-platform mobile-bearing prostheses to fixed bearing prostheses for total knee arthroplasty. Results from the meta-analyses of clinical scores, range of motion, radiographic outcome, rates of osteolysis, loosening, and progressive radiolucent lines, component alignment, adverse events, and revisions indicated no significant differences between rotating-platform and fixed-bearing designs, with the exception of tibial component alignment in the AP plane in favour of fixed-bearing design. However, this effect was small and clinically insignificant.


تفاصيل تمويل المنشور +
التمويل:
Industry funded
الراعي:
DePuy (Warsaw, IN, USA), Zimmer (Warsaw, IN, USA), and Medtronic (Minneapolis, IN, USA).
التعارضات:
Other

مخاطر التحيز

10/10

معايير الإبلاغ

17/20

مؤشر الهشاشة

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Introduction

4/4

Accessing Data

3/4

Analysing Data

3/4

Results

3/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Mobile-bearing prostheses in total knee arthroplasty (TKA) are cited to improve the biomechanics of the knee and emulate its natural kinematics, thereby reducing polyethylene wear when compared to fixed bearings. Previous meta-analyses comparing mobile- to fixed-bearing TKAs often failed to distinguish between the several mobile-bearing subgroups. Several mobile-bearing designs exist, including rotating-platform, meniscal-bearing, and AP glide-and-rotation designs. As such, this meta-analysis was performed to specifically compare mobile-bearings of the rotating-platform design to fixed-bearings designs following TKA.

ما هو سؤال البحث الرئيسي؟

How do rotating-platform mobile-bearings compare to fixed-bearings with respect to clinical performance, component alignment, incidence of adverse events, and revision rates following total knee arthroplasty?

خصائص الدراسة +
Data Source:
An electronic search was conducted in the Medline, EMBASE, Google Scholar, and Cochrane databases for studies published between January 1990 and May 2013. Additionally, reference lists of systematic reviews and meta-analyses were searched.
Index Terms:
Search terms included ‘‘total knee’’ and [‘‘mobile bearing’’ or ‘‘rotating-platform’’] and [‘‘fixed-bearing’’ or ‘‘meta-analysis’’ or ‘‘systematic review’’].
Study Selection:
Comparative studies of TKAs performed with rotating-platform and fixed-bearing prostheses were included. Two independent reviewers reviewed studies for inclusion; disagreements were resolved via consensus. 41 studies were included overall: 17 were included for meta-analysis (15 randomized controlled trials without blinding or prospective comparative studies and 2 retrospective comparative studies).
Data Extraction:
Extraction was performed independently into a data abstraction form. Outcomes of interest included: clinical performance at final follow-up (Knee Society scores, Hospital for Special Surgery, and SF-12 Physical and Mental Components, ROM, and radiolucent lines), component alignment, reported complications (anterior knee pain, patellar tilt, and manipulation for stiffness), and revision rates.
Data Synthesis:
A random-effects model was used to pool the odds ratios and associated 95% confidence levels (CI) of dichotomous outcomes. Standardized mean differences or weighted mean differences were calculated for continuous variables using a random-effects model. Heterogeneity was evaluated using Cochran's Q-test and the I-squared statistic. Publication bias was assessed using funnel plots. Duval and Tweedie's trim and fill method was used to impute missing studies. The Centre for Evidence Based Medicine was used to rate the level of evidence. Multiple publications of the same population were pooled as one study. Comprehensive Meta Analysis 2.2.064 software was used for statistical analysis.
ما هي النتائج المهمة؟
  • No significant differences were observed between groups when a meta-analysis was performed for Knee Society Function scores in 8 studies (p=0.465), Knee Society Knee scores in 10 studies (p=0.429), Hospital for Special Surgery scores in 3 studies (p=0.510), SF-12 Physical scores in 3 studies (p=0.501), and SF-12 Mental scores in 3 studies (p=0.209).
  • Range of motion for flexion contracture (4 studies), extension (3 studies), flexion (9 studies), and total range of motion (8 studies) were comparable between groups (p=0884; p=0.499; p=0.058; p=0.685; respectively).
  • No between group differences were observed for radiographic evaluations for palmar tilt (3 studies; p=0.670), radiolucent lines (6 studies; p=0.348), nonprogressive radiolucent lines (3 studies; p=0.903), and tibial radiolucent lines (3 studies; p=0.538).
  • Rates of radiographic osteolysis (3 cases total; rotation-platform group), radiographic loosening 2 cases total; rotation-platform group), and progressive radiolucent lines (1 case in total; fixed bearing group) were not statistically different between groups.
  • Tibial component alignment in the AP plane (3 studies) favoured the fixed-bearing group (standardized mean difference, 0.229; 95% CI 0.035–0.422; p=0.020), although effect size was small and not clinically important. Femoral component alignment in the AP plane and tibial component alignment in the sagittal plane were similar between groups (3 studies each; p=0.894 and p=0.379, respectively).
  • Incidence of anterior knee pain (3 studies), and stiffness requiring manipulation (4 studies) were comparable between groups (p=0.821 and p=0.326 respectively).
  • Number of patients requiring revision for deep infection (3 studies; 2 revisions in fixed bearing group), loosening (3 studies; 3 cases in rotating-platform group), or for any reason (9 studies; 4 revision in each group) were not significantly difference between groups.
ما الذي يجب أن أتذكره أكثر؟

Results from the meta-analyses of clinical scores, range of motion, radiographic outcome, rates of osteolysis, loosening (progressive radiolucent lines), component alignment, adverse events, and revisions indicated no significant differences between rotating-platform and fixed-bearing designs, with the exception of tibial component alignment in the AP plane in favour of fixed-bearing design. However, this effect was small and clinically insignificant.

كيف سيؤثر ذلك على رعاية مرضاي؟

The findings of this study demonstrated no clinically important differences between total knee arthroplasty performed using rotating-platform mobile-bearing prostheses versus fixed-bearing prostheses. The authors recommended that future research focus on other factors that may influence outcome.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
Close Dialog
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Rotating-platform TKA comparable to fixed-bearing TKA. OE Journal. 2014;2(19):7. Available from: https://myorthoevidence.com/AceReport/Show/rotating-platform-tka-comparable-to-fixed-bearing-tka

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report