ARTHROPLASTY
Rotating-platform TKA comparable to fixed-bearing TKA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(19):7 Clin Orthop Relat Res. 2014 Jul;472(7):2185-93. doi: 10.1007/s11999-014-3539-4. Epub 2014 Mar 4.
Mitwirkende Autoren

JT Moskal SG Capps

17 studies were included in this meta-analysis (15 randomized controlled trials without blinding or prospective comparative studies and 2 retrospective comparative studies) comparing the outcomes of rotating-platform mobile-bearing prostheses to fixed bearing prostheses for total knee arthroplasty. Results from the meta-analyses of clinical scores, range of motion, radiographic outcome, rates of osteolysis, loosening, and progressive radiolucent lines, component alignment, adverse events, and revisions indicated no significant differences between rotating-platform and fixed-bearing designs, with the exception of tibial component alignment in the AP plane in favour of fixed-bearing design. However, this effect was small and clinically insignificant.


Details zur Finanzierung der Veröffentlichung +
Finanzierung:
Industry funded
Sponsor:
DePuy (Warsaw, IN, USA), Zimmer (Warsaw, IN, USA), and Medtronic (Minneapolis, IN, USA).
Interessenkonflikte:
Other

Risiko der Voreingenommenheit

10/10

Kriterien für die Berichterstattung

17/20

Fragilitäts-Index

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

Ja = 1

Ungewiss = 0.5

Nicht relevant = 0

Nein = 0

Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.

4/4

Introduction

4/4

Accessing Data

3/4

Analysing Data

3/4

Results

3/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.

Warum wurde diese Studie jetzt benötigt?

Mobile-bearing prostheses in total knee arthroplasty (TKA) are cited to improve the biomechanics of the knee and emulate its natural kinematics, thereby reducing polyethylene wear when compared to fixed bearings. Previous meta-analyses comparing mobile- to fixed-bearing TKAs often failed to distinguish between the several mobile-bearing subgroups. Several mobile-bearing designs exist, including rotating-platform, meniscal-bearing, and AP glide-and-rotation designs. As such, this meta-analysis was performed to specifically compare mobile-bearings of the rotating-platform design to fixed-bearings designs following TKA.

Was war die wichtigste Forschungsfrage?

How do rotating-platform mobile-bearings compare to fixed-bearings with respect to clinical performance, component alignment, incidence of adverse events, and revision rates following total knee arthroplasty?

Merkmale der Studie +
Datenquelle:
An electronic search was conducted in the Medline, EMBASE, Google Scholar, and Cochrane databases for studies published between January 1990 and May 2013. Additionally, reference lists of systematic reviews and meta-analyses were searched.
Index Begriffe:
Search terms included ‘‘total knee’’ and [‘‘mobile bearing’’ or ‘‘rotating-platform’’] and [‘‘fixed-bearing’’ or ‘‘meta-analysis’’ or ‘‘systematic review’’].
Auswahl der Studie:
Comparative studies of TKAs performed with rotating-platform and fixed-bearing prostheses were included. Two independent reviewers reviewed studies for inclusion; disagreements were resolved via consensus. 41 studies were included overall: 17 were included for meta-analysis (15 randomized controlled trials without blinding or prospective comparative studies and 2 retrospective comparative studies).
Datenextraktion:
Extraction was performed independently into a data abstraction form. Outcomes of interest included: clinical performance at final follow-up (Knee Society scores, Hospital for Special Surgery, and SF-12 Physical and Mental Components, ROM, and radiolucent lines), component alignment, reported complications (anterior knee pain, patellar tilt, and manipulation for stiffness), and revision rates.
Daten-Synthese:
A random-effects model was used to pool the odds ratios and associated 95% confidence levels (CI) of dichotomous outcomes. Standardized mean differences or weighted mean differences were calculated for continuous variables using a random-effects model. Heterogeneity was evaluated using Cochran's Q-test and the I-squared statistic. Publication bias was assessed using funnel plots. Duval and Tweedie's trim and fill method was used to impute missing studies. The Centre for Evidence Based Medicine was used to rate the level of evidence. Multiple publications of the same population were pooled as one study. Comprehensive Meta Analysis 2.2.064 software was used for statistical analysis.
Was waren die wichtigsten Ergebnisse?
  • No significant differences were observed between groups when a meta-analysis was performed for Knee Society Function scores in 8 studies (p=0.465), Knee Society Knee scores in 10 studies (p=0.429), Hospital for Special Surgery scores in 3 studies (p=0.510), SF-12 Physical scores in 3 studies (p=0.501), and SF-12 Mental scores in 3 studies (p=0.209).
  • Range of motion for flexion contracture (4 studies), extension (3 studies), flexion (9 studies), and total range of motion (8 studies) were comparable between groups (p=0884; p=0.499; p=0.058; p=0.685; respectively).
  • No between group differences were observed for radiographic evaluations for palmar tilt (3 studies; p=0.670), radiolucent lines (6 studies; p=0.348), nonprogressive radiolucent lines (3 studies; p=0.903), and tibial radiolucent lines (3 studies; p=0.538).
  • Rates of radiographic osteolysis (3 cases total; rotation-platform group), radiographic loosening 2 cases total; rotation-platform group), and progressive radiolucent lines (1 case in total; fixed bearing group) were not statistically different between groups.
  • Tibial component alignment in the AP plane (3 studies) favoured the fixed-bearing group (standardized mean difference, 0.229; 95% CI 0.035–0.422; p=0.020), although effect size was small and not clinically important. Femoral component alignment in the AP plane and tibial component alignment in the sagittal plane were similar between groups (3 studies each; p=0.894 and p=0.379, respectively).
  • Incidence of anterior knee pain (3 studies), and stiffness requiring manipulation (4 studies) were comparable between groups (p=0.821 and p=0.326 respectively).
  • Number of patients requiring revision for deep infection (3 studies; 2 revisions in fixed bearing group), loosening (3 studies; 3 cases in rotating-platform group), or for any reason (9 studies; 4 revision in each group) were not significantly difference between groups.
Was sollte ich mir besonders merken?

Results from the meta-analyses of clinical scores, range of motion, radiographic outcome, rates of osteolysis, loosening (progressive radiolucent lines), component alignment, adverse events, and revisions indicated no significant differences between rotating-platform and fixed-bearing designs, with the exception of tibial component alignment in the AP plane in favour of fixed-bearing design. However, this effect was small and clinically insignificant.

Wie wird sich dies auf die Behandlung meiner Patienten auswirken?

The findings of this study demonstrated no clinically important differences between total knee arthroplasty performed using rotating-platform mobile-bearing prostheses versus fixed-bearing prostheses. The authors recommended that future research focus on other factors that may influence outcome.

HAFTUNGSAUSSCHLUSS

Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.

0 von 4 monatliche KOSTENLOSE Artikel freigeschaltet
Sie haben Ihr Limit von 4 kostenlosen Artikeln in diesem Monat erreicht

Zugang zu OrthoEvidence für nur $1,99 pro Woche.

Bleiben Sie auf dem Laufenden mit den neuesten Beweisen. Jederzeit kündbar.
  • Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
  • Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
  • Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Upgrade
Close Dialog
Willkommen zurück!
Passwort vergessen?
Starten Sie Ihre KOSTENLOSE Testversion noch heute!

Ihr Konto ist verbunden mit
und umfasst den kostenlosen Zugang zu OrthoEvidence


ODER
Passwort vergessen?

ODER
Bitte überprüfen Sie Ihre E-Mail

Wenn ein Konto mit der angegebenen E-Mail-Adresse existiert, wird Ihnen eine E-Mail zum Zurücksetzen des Passworts zugesandt. Wenn Sie keine E-Mail sehen, überprüfen Sie bitte Ihren Spam- oder Junk-Ordner.

Für weitere Hilfe, kontaktieren Sie unser Support-Team.

Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Übersetzen ACE Report

OrthoEvidence nutzt einen externen Übersetzungsdienst, um Inhalte in mehreren Sprachen zugänglich zu machen. Bitte beachten Sie, dass trotz aller Bemühungen um Genauigkeit die Übersetzungen nicht immer perfekt sind.

Wie man dies zitiert ACE Report

OrthoEvidence. Rotating-platform TKA comparable to fixed-bearing TKA. OE Journal. 2014;2(19):7. Available from: https://myorthoevidence.com/AceReport/Show/rotating-platform-tka-comparable-to-fixed-bearing-tka

Zitat kopieren
Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Premium-Mitglied-Funktion

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem Premium-Konto von OrthoEvidence angemeldet sein.

Teilen Sie dies ACE Report