OE Journal. 2025;13(3):858 patients with high-energy pilon fractures were randomized to evaluate the efficacy of locking plates against convention nonlocking plates, over 1 year. Radiographic data was evaluated for loss of reduction using Mortise/ AP and lateral radiographs of the ankle, and functional outcomes were assessed using ankle hindfoot scores, and Short Musculoskeletal Function Assessment (SMFA). The evidence presented in this study demonstrates that both treatments perform comparably in each outcome measurement, but the authors of the study indicate that the results may suffer from type II error due to the low incidence of reduction loss.
Relatório da Conferência
Este Relatório ACE é um resumo de uma apresentação ou resumo de uma conferência. A informação fornecida limitou a capacidade de fornecer uma avaliação exacta do risco de viés ou da qualidade global. Por favor, interprete os resultados com cautela, uma vez que os ensaios podem estar em curso e podem ter sido apresentados resultados selecionados.
Porque é que este estudo era necessário agora?
High-energy pilon fractures are conventionally treated with nonlocking plates. This study was needed to evaluate and compare the clinical and radiographic outcomes associated with the use of locking plates against nonlocking plates for the management of high-energy pilon fractures.
Qual era a principal questão de investigação?
Do locking plates present comparable clinical and radiographic outcomes to nonlocking plates for the treatment of high-energy pilon fractures, assessed over 1 year?
- 2 of 15 (13%) of the fractures in the nonlocking group demonstrated loss of reduction >5 degrees, compared to 3 of 19 (16%) in the lock group (p= 0.999)
- No soft-tissue complications requiring surgical intervention were observed
- 1 patient in the lock group presented with deep infection, 2 with nonunions, and 2 with hardware failures. 1 patient in the nonlock group presented with hardware failure and 1 infected nonunion
- Average follow-up in 8 patients in the lock group, and 10 in the nonlock group, was reported at 35.6 SD 16.0 months.
- No significant differences between the lock and nonlock groups for ankle hindfoot scores: 71.75 SD 71.75 versus 66.1 SD 23.8 respectively (p= 0.625)
- No significant difference between groups was apparent for SMFA-BI (bother index) scores with 7175 SD 25.4 in the lock group compared to 66.1 SD 23.8 in the nonlock group (p= 0.625)
- SMFA-FI (function index) analysis between the lock and nonlock groups revealed no significant difference with a score of 32.9 SD 36.2 in the lock group compared to 25.7 SD 20.2 in the nonlock group (p= 0.587)
De que é que me devo lembrar mais?
Both the locking plate and the nonlocking plates performed comparably for all evaluated outcomes: loss of reduction and radiologic analyses.
Como é que isto afectará o tratamento dos meus doentes?
The evidence presented in this study demonstrates that both locking and nonlocking plates are comparable interventions for high-energy pilon fractures. The results presented in this study may be subject to type II error as indicated by the low incidence of reduction loss.
AVISO LEGAL
O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.