TRAUMA
Circular fixator application for bicondylar tibial plateau fractures reduces hospital stay .
High Impact
This study has been identified as potentially high impact. OE's AI-driven High Impact metric estimates the influence a paper is likely to have by integrating signals from both the journal in which it is published and the scientific content of the article itself. Developed using state-of-the-art natural language processing, the OE High Impact model more accurately predicts a study's future citation performance than journal impact factor alone. This enables earlier recognition of clinically meaningful research and helps readers focus on articles most likely to shape future practice.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2025;13(3):41 J Bone Joint Surg Am. 2006 Dec;88(12):2613-23.

82 patients with 83 displaced bicondylar tibial plateau fractures were randomized to receive standard open reduction and internal fixation with medial and lateral plates or percutaneous and/or limited open fixation and application of a circular fixator. At the 2 year follow-up there was no significant difference in clinical outcomes between the open reduction group and circular fixator group, however, a marginally faster return to function was observed at 6 months in the circular fixator group. Additionally, patients in the circular fixator group required a significantly shorter hospital stay than the patients in the internal fixation group, and the open reduction and internal fixation group exhibited significantly more complications.


Publication Funding Details +
Funding:
Industry funded
Sponsor:
Smith and Nephew, Ltd., and the Simon Fraser Orthopaedic Fund
Conflicts:
None disclosed

Risk of Bias

6.5/10

Reporting Criteria

16/20

Fragility Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Yes = 1

Uncertain = 0.5

Not Relevant = 0

No = 0

The Reporting Criteria Assessment evaluates the transparency with which authors report the methodological and trial characteristics of the trial within the publication. The assessment is divided into five categories which are presented below.

2/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

The Fragility Index is a tool that aids in the interpretation of significant findings, providing a measure of strength for a result. The Fragility Index represents the number of consecutive events that need to be added to a dichotomous outcome to make the finding no longer significant. A small number represents a weaker finding and a large number represents a stronger finding.

Why was this study needed now?

Open reduction and internal fixation (ORIF) of bicondylar fractures of the tibial plateau is the current gold standard for treatment. However, damage caused by the original injury and the surgical procedure can lead to a high rate of complication. Alternative methods of treating bicondylar fractures of the tibial plateau have become increasingly common due to negative effects of complications associated with ORIF. One of these alternative treatments is circular frame fixation with or without percutaneous lag-screw fixation. This study aimed to determine whether percutaneous and/or limited open fixation and application of a circular fixator provides better fracture reduction quality than standard open reduction and internal fixation with medial and lateral plates.

What was the principal research question?

Does percutaneous and/or limited open fixation and application of a circular fixator improve clinical outcomes of patients with displaced bicondylar tibial plateau fractures when compared to open reduction and internal fixation with medial and lateral plates 2 years after surgery?

Study Characteristics +
Population:
82 patients with 83 displaced bicondylar tibial plateau fractures
Intervention:
Circular fixator Group: Patients were managed with a closed, percutaneous, or limited open reduction of the articular surface followed by insertion of percutaneous lag screws for stabilization. The circular fixator was composed of 3 or 4 rings in every case. (Mean age: 46.2 years; 29 males) (n=42).
Comparison:
ORIF Group: Patients underwent open reduction and internal fixation with medial and lateral plates (Mean age: 43.3 years; 23 males) (n=40).
Outcomes:
The Hospital for Special Surgery (HSS) knee score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Short Form-36 (SF-36) General Health Survey were assessed.
Methods:
RCT: prospective; multiple centers (5).
Time:
2 years (outcomes assessed at 6 months, 1 year, and 2 years).
What were the important findings?
  • At 6 months, the HSS knee score was 72 for the circular fixator group and 61 for the open reduction group (p=0.064). At 1 year the HSS knee score was 72 for the circular fixator group and 67 for the open reduction group (p=0.406). At 2 years, the HSS knee score was 75 for the circular fixator group and 68 for the open reduction group, which was found to be not statistically significant (p=0.307).
  • The difference in mean pain, stiffness, or function on the WOMAC score between the circular fixator group and open reduction group at 6 months, 1 year, and 2 years was found to be not clinically significant (p>0.05), and no difference in total arc of knee motion was apparent (p>0.05).
  • Both the circular fixator group and open reduction group achieved significantly lower mean WOMAC scores at the 2 year follow-up relative to preoperative scores (p<0.05).
  • The difference between preoperative and 2 year follow-up SF-36 scores were found to be clinically significant for both the circular fixator group (p=0.001) and the open reduction group (p=0.014). At the 2 year follow-up, the difference between the circular fixator group and open reduction group was not significant for all SF-36 domains except for the bodily pain domain, which was significantly better for the circular fixator group (p=0.041).
  • The circular fixation group required a significantly shorter hospital stay (9.9 days) than the open fixation group (23.4 days) (p=0.024) along with significantly less Intraoperative blood loss (213 mL vs. 544 mL respectively; p= 0.006).
  • The quality of osseous reduction was similar between groups. Patient ability to return to preinjury activities at 6 months and 12 months was superior in the circular fixation group compared to the ORIF groups (p=0.031 and p=0.024 respectively) but not at 2 years.
  • 7 (18%) ORIF patients reported a deep infection. The number of unplanned repeat surgical interventions, along with their severity, was greater in the ORIF group (37 procedures) compared with the circular fixator group (16 procedures) (p= 0.001).
What should I remember most?

The data suggested that percutaneous and/or limited open fixation and application of a circular fixator did not significantly improve clinical outcomes of the knee but significantly reduced the required hospital stay when compared to standard open reduction and internal fixation with medial and lateral plates. Complications were also significantly more incident in the open reduction and internal fixation group.

How will this affect the care of my patients?

The study suggests that percutaneous and/or limited open fixation and application of a circular fixator may not significantly improve clinical outcomes when compared to standard open reduction and internal fixation with medial and lateral plates over a 2 year follow-up period. Further research using larger sample sizes are required to confirm the findings of this study.

DISCLAIMER

This content found on this page is for informational purposes only and is not intended to be a substitute for professional medical advice, diagnosis, or treatment. If you require medical treatment, always seek the advice of your physician or go to your nearest emergency department. The opinions, beliefs, and viewpoints expressed by the individuals on the content found on this page do not reflect the opinions, beliefs, and viewpoints of OrthoEvidence.

0 of 4 monthly FREE articles unlocked
You've reached your limit of 4 free articles views this month

Access to OrthoEvidence for as little as $1.99 per week.

Stay connected with latest evidence. Cancel at any time.
  • Critical appraisals of the latest, high-impact randomized controlled trials and systematic reviews in orthopaedics
  • Access to OrthoEvidence podcast content, including collaborations with the Journal of Bone and Joint Surgery, interviews with internationally recognized surgeons, and roundtable discussions on orthopaedic news and topics
  • Subscription to The Pulse, a twice-weekly evidence-based newsletter designed to help you make better clinical decisions
Upgrade
Welcome Back!
Forgot Password?
Start your FREE trial today!

Your account will be affiliated with
and includes free access to OrthoEvidence


OR
Forgot Password?

OR
Please check your email

If an account exists with the provided email address, a password reset email will be sent to you. If you don't see an email, please check your spam or junk folder.

For further assistance, contact our support team.

Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Translate ACE Report

OrthoEvidence utilizes a third-party translation service to make content accessible in multiple languages. Please note that while every effort is made to ensure accuracy, translations may not always be perfect.

How to cite this ACE Report

OrthoEvidence. Circular fixator application for bicondylar tibial plateau fractures reduces hospital stay. OE Journal. 2025;13(3):41. Available from: https://myorthoevidence.com/AceReport/Show/circular-fixator-application-for-bicondylar-tibial-plateau-fractures-reduces-hospital-stay

Copy Citation
Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Premium Member Feature

To access this feature, you must be logged into a premium OrthoEvidence account.

Share this ACE Report