ACE Report Cover
Circular fixator application for bicondylar tibial plateau fractures reduces hospital stay
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Sprache
Download Download Download
Herunterladen
Cite this Report Cite this Report Cite this Report
Zitieren
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoriten
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Sprache
Download Download Download
Herunterladen
Cite this Report Cite this Report Cite this Report
Zitieren
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoriten
TRAUMA
Circular fixator application for bicondylar tibial plateau fractures reduces hospital stay .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2025;13(3):41 J Bone Joint Surg Am. 2006 Dec;88(12):2613-23.

82 patients with 83 displaced bicondylar tibial plateau fractures were randomized to receive standard open reduction and internal fixation with medial and lateral plates or percutaneous and/or limited open fixation and application of a circular fixator. At the 2 year follow-up there was no significant difference in clinical outcomes between the open reduction group and circular fixator group, however, a marginally faster return to function was observed at 6 months in the circular fixator group. Additionally, patients in the circular fixator group required a significantly shorter hospital stay than the patients in the internal fixation group, and the open reduction and internal fixation group exhibited significantly more complications.


Details zur Finanzierung der Veröffentlichung +
Finanzierung:
Industry funded
Sponsor:
Smith and Nephew, Ltd., and the Simon Fraser Orthopaedic Fund
Conflicts:
None disclosed

Risiko der Voreingenommenheit

6,5/10

Kriterien für die Berichterstattung

16/20

Fragilitäts-Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Ja = 1

Ungewiss = 0.5

Nicht relevant = 0

Nein = 0

Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.

2/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.

Warum wurde diese Studie jetzt benötigt?

Open reduction and internal fixation (ORIF) of bicondylar fractures of the tibial plateau is the current gold standard for treatment. However, damage caused by the original injury and the surgical procedure can lead to a high rate of complication. Alternative methods of treating bicondylar fractures of the tibial plateau have become increasingly common due to negative effects of complications associated with ORIF. One of these alternative treatments is circular frame fixation with or without percutaneous lag-screw fixation. This study aimed to determine whether percutaneous and/or limited open fixation and application of a circular fixator provides better fracture reduction quality than standard open reduction and internal fixation with medial and lateral plates.

Was war die wichtigste Forschungsfrage?

Does percutaneous and/or limited open fixation and application of a circular fixator improve clinical outcomes of patients with displaced bicondylar tibial plateau fractures when compared to open reduction and internal fixation with medial and lateral plates 2 years after surgery?

Merkmale der Studie +
Population:
82 patients with 83 displaced bicondylar tibial plateau fractures
Intervention:
Circular fixator Group: Patients were managed with a closed, percutaneous, or limited open reduction of the articular surface followed by insertion of percutaneous lag screws for stabilization. The circular fixator was composed of 3 or 4 rings in every case. (Mean age: 46.2 years; 29 males) (n=42).
Comparison:
ORIF Group: Patients underwent open reduction and internal fixation with medial and lateral plates (Mean age: 43.3 years; 23 males) (n=40).
Outcomes:
The Hospital for Special Surgery (HSS) knee score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Short Form-36 (SF-36) General Health Survey were assessed.
Methods:
RCT: prospective; multiple centers (5).
Time:
2 years (outcomes assessed at 6 months, 1 year, and 2 years).
Was waren die wichtigsten Ergebnisse?
  • At 6 months, the HSS knee score was 72 for the circular fixator group and 61 for the open reduction group (p=0.064). At 1 year the HSS knee score was 72 for the circular fixator group and 67 for the open reduction group (p=0.406). At 2 years, the HSS knee score was 75 for the circular fixator group and 68 for the open reduction group, which was found to be not statistically significant (p=0.307).
  • The difference in mean pain, stiffness, or function on the WOMAC score between the circular fixator group and open reduction group at 6 months, 1 year, and 2 years was found to be not clinically significant (p>0.05), and no difference in total arc of knee motion was apparent (p>0.05).
  • Both the circular fixator group and open reduction group achieved significantly lower mean WOMAC scores at the 2 year follow-up relative to preoperative scores (p<0.05).
  • The difference between preoperative and 2 year follow-up SF-36 scores were found to be clinically significant for both the circular fixator group (p=0.001) and the open reduction group (p=0.014). At the 2 year follow-up, the difference between the circular fixator group and open reduction group was not significant for all SF-36 domains except for the bodily pain domain, which was significantly better for the circular fixator group (p=0.041).
  • The circular fixation group required a significantly shorter hospital stay (9.9 days) than the open fixation group (23.4 days) (p=0.024) along with significantly less Intraoperative blood loss (213 mL vs. 544 mL respectively; p= 0.006).
  • The quality of osseous reduction was similar between groups. Patient ability to return to preinjury activities at 6 months and 12 months was superior in the circular fixation group compared to the ORIF groups (p=0.031 and p=0.024 respectively) but not at 2 years.
  • 7 (18%) ORIF patients reported a deep infection. The number of unplanned repeat surgical interventions, along with their severity, was greater in the ORIF group (37 procedures) compared with the circular fixator group (16 procedures) (p= 0.001).
Was sollte ich mir besonders merken?

The data suggested that percutaneous and/or limited open fixation and application of a circular fixator did not significantly improve clinical outcomes of the knee but significantly reduced the required hospital stay when compared to standard open reduction and internal fixation with medial and lateral plates. Complications were also significantly more incident in the open reduction and internal fixation group.

Wie wird sich dies auf die Behandlung meiner Patienten auswirken?

The study suggests that percutaneous and/or limited open fixation and application of a circular fixator may not significantly improve clinical outcomes when compared to standard open reduction and internal fixation with medial and lateral plates over a 2 year follow-up period. Further research using larger sample sizes are required to confirm the findings of this study.

HAFTUNGSAUSSCHLUSS

Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.

0 von 4 monatliche KOSTENLOSE Artikel freigeschaltet
Sie haben Ihr Limit von 4 kostenlosen Artikeln in diesem Monat erreicht

Zugang zu OrthoEvidence für nur $1,99 pro Woche.

Bleiben Sie auf dem Laufenden mit den neuesten Beweisen. Jederzeit kündbar.
  • Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
  • Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
  • Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Upgrade
Willkommen zurück!
Passwort vergessen?
Starten Sie Ihre KOSTENLOSE Testversion noch heute!

Ihr Konto ist verbunden mit
und umfasst den kostenlosen Zugang zu OrthoEvidence


ODER
Passwort vergessen?

ODER
Bitte überprüfen Sie Ihre E-Mail

Wenn ein Konto mit der angegebenen E-Mail-Adresse existiert, wird Ihnen eine E-Mail zum Zurücksetzen des Passworts zugesandt. Wenn Sie keine E-Mail sehen, überprüfen Sie bitte Ihren Spam- oder Junk-Ordner.

Für weitere Hilfe, kontaktieren Sie unser Support-Team.

Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Übersetzen ACE Report

OrthoEvidence nutzt einen externen Übersetzungsdienst, um Inhalte in mehreren Sprachen zugänglich zu machen. Bitte beachten Sie, dass trotz aller Bemühungen um Genauigkeit die Übersetzungen nicht immer perfekt sind.

Wie man dies zitiert ACE Report

OrthoEvidence. Circular fixator application for bicondylar tibial plateau fractures reduces hospital stay. OE Journal. 2025;13(3):41. Available from: https://myorthoevidence.com/AceReport/Show/circular-fixator-application-for-bicondylar-tibial-plateau-fractures-reduces-hospital-stay

Zitat kopieren
Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Premium-Mitglied-Funktion

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem Premium-Konto von OrthoEvidence angemeldet sein.

Teilen Sie dies ACE Report