ARTHROPLASTY
No radiographic or clinical benefit of patient specific instrumentation in TKA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2016;4(22):3 Acta Orthop. 2016 Aug;87(4):386-94
المؤلفون المساهمون

HJ Huijbregts RJ Khan E Sorensen DP Fick S Haebich

21 studies evaluating the use of patient-specific instrumentation in total knee arthroplasty were included in this meta-analysis and systematic review. Pooled analyses demonstrated no significant difference between patient-specific instrumentation systems and conventional instruments in the incidence of excessive malalignment (>3 degrees deviation) in hip-knee-ankle angle. Additionally, the incidence of femoral component outliers in the coronal, sagittal, and axial planes, and tibial component outliers in the sagittal plane did not significantly differ, while tibial component outliers in the coronal plane occurred significantly more often with patient-specific instrumentation. No significant differences were found in short-term (3-month) clinical outcome measures. Two analyses which did favour patient-specific instrumentation were a lower number of surgical trays required during the procedure and shorter length of stay.


تفاصيل تمويل المنشور +
التمويل:
Not Reported
التعارضات:
None disclosed

مخاطر التحيز

9/10

معايير الإبلاغ

19/20

مؤشر الهشاشة

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Introduction

4/4

Accessing Data

4/4

Analysing Data

4/4

Results

3/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Patient-specific instrumentation (PSI) for component implantation in total knee arthroplasty is a recently-developed technology, with a number of randomized controlled trials performed investigating the systems of major orthopaedic device companies. PSI systems were designed to improve component alignment in these procedures, though conclusions on efficacy from previous studies vary widely. A synthesis of the literature was therefore needed to assess the current status of the role of PSI in TKA procedures.

ما هو سؤال البحث الرئيسي؟

In total knee arthroplasty, are there any significant differences in radiographic alignment accuracy of component placement, perioperative parameters (blood loss, operative time, etc), and patient-reported outcome measures between patient-specific instrumentation and conventional instrumentation?

خصائص الدراسة +
Data Source:
MEDLINE and EMBASE were searched for relevant articles published up to May 28 2015.
Index Terms:
Keyword terms included: "knee arthroplasty", "knee replacement", "patient match", "patient specific", and "custom".
Study Selection:
Eligibility criteria included: a randomized or quasi-randomized controlled trial design; enrolled patients requiring total knee arthroplasty; and allocated patients to treatment with either patient-specific instrumentation or conventional intra- and extramedullary guides. The selection was performed independently by two reviewers, with disagreement resolved through discussion. A total of 21 studies. with data sampled from 1587 procedures, were selected for final inclusion.
Data Extraction:
Data extraction was performed by a single reviewer.
Data Synthesis:
Statistical analysis was performed using Review Manager software (RevMan 5.3). Continuous outcomes were expressed as weighted mean differences, and dichotomous outcomes as risk ratios, both with 95% confidence intervals. All analyses were performed under both a fixed-effects and random-effects model. Heterogeneity was assessed using the I-squared (I^2) statistic.
ما هي النتائج المهمة؟
  • There was no significant difference in the incidence of outliers in hip-knee-ankle angle (>3deg deviation from neutral) overall between patient-specific and conventional instruments (13 studies; RR 1.02 [95%CI 0.82-1.27]; p=0.86), or when specific products (PSI-Zimmer, Signature-Biomet, TruMatch-DePuy, Visionaire-Smith & Nephew) were analyzed as subgroups (all p>0.05).
  • There was no significant difference between groups in the incidence of femoral component outliers in the coronal plane (11 studies; RR 0.81 [95%CI 0.6-1.09]). The incidence of tibial component outliers in the coronal plane was significantly higher among patient specific groups (11 studies; RR 1.64 [95%CI 1.12-2.42]).
  • There were no significant differences between groups in the incidence of outliers in the sagittal plane of either the femoral component (8 studies; RR 0.97 [95%CI 0.82-1.15]) or the tibial component (8 studies; RR 1.47 [95%CI 0.97-2.23]).
  • There was no significant difference between groups in the incidence of femoral component rotational outliers (6 studies; RR 0.80 [95%CI 0.52-1.23]).
  • No significant difference between patient-specific and conventional instrumentation groups was observed in operative time (12 studies; MD -0.90min [95%CI -4.78, 2.98]; p=0.65) or tourniquet time (3 studies; MD -6min [95%CI -21.2, 10.1]). No significant differences were observed in analyses of intra-, postoperative, and total perioperative blood loss.
  • The length of hospital stay was shortened by 8 hours (95%CI 3.1-12.5) following the use of patient-specific instrumentation versus conventional instrumentation.
  • Two studies demonstrated a significantly lower use of surgical trays (MD 4 trays [95%CI 2.58-5.61]) with patient-specific versus conventional instrumentation.
  • No significant differences between groups were observed in patient-reported outcome measures at 3 months, including Knee Society Scores and Oxford Knee Scores.
ما الذي يجب أن أتذكره أكثر؟

In total knee arthroplasty, the use of patient-specific instrumentation did not significantly reduce the incidence of malalignment overall, or of individual components in the coronal, sagittal, and axial planes. In fact, the incidence of tibial component outliers in the coronal plane was significantly higher following TKA with patient-specific instrumentation. No significant differences were observed in analyses of operative time, blood loss, or short-term clinical outcome. Advantages with the use of patient-specific instrumentation were noted concerning the number of surgical trays during the procedure, as well as in length of hospital stay.

كيف سيؤثر ذلك على رعاية مرضاي؟

The results of this study suggest that there is no radiographic or clinical advantage to the use of patient-specific instrumentation in total knee arthroplasty, and in fact may compromise alignment of the tibial component. Benefits of patient-specific instrumentation appear limited to parameters of resource consumption, as evidenced by the analyses on surgical trays and the short, but significant, reduction in hospital stay. An economic analysis is needed to determine if these improvements in efficiency off-set the cost of the patient-specific instrumentation technology itself, as well as the preoperative imaging required to make the technology.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
Close Dialog
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. No radiographic or clinical benefit of patient specific instrumentation in TKA. OE Journal. 2016;4(22):3. Available from: https://myorthoevidence.com/AceReport/Show/no-radiographic-or-clinical-benefit-of-patient-specific-instrumentation-in-tka

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report