ARTHROPLASTY
Femoral neck fractures: Similar function, but higher revision rates using PCU-THR vs HA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(10):6 Bone Joint J. 2013 May;95-B(5):609-15. doi: 10.1302/0301-620X.95B5.31083

96 patients aged 70 or over who had suffered femoral neck fractures (32 at final follow-up) were randomized to receive either a total hip replacement with a polycarbonate-urethane acetabular component (PCU-THR), or a hemiarthroplasty (HA) treatment. The purpose of this study was to evaluate the functional outcomes associated with these two treatments. Results indicated that there was no difference in function at 3 months, 1 year, 2 years or 3 years post-operation and that pain was worse in the PCU-THR group at 1 and 2 years. Lastly, higher revision rates were observed in the PCU-THR group.


Detalles de la financiación de la publicación +
Financiación:
Not Reported
Conflictos:
None disclosed

Riesgo de sesgo

3,5/10

Criterios de información

17/20

Índice de fragilidad

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sí = 1

Incierto = 0,5

No relevante = 0

No = 0

La evaluación de los criterios de información evalúa la transparencia con la que los autores informan de las características metodológicas y del ensayo dentro de la publicación. La evaluación se divide en cinco categorías que se presentan a continuación.

3/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

El Índice de Fragilidad es una herramienta que ayuda en la interpretación de hallazgos significativos, proporcionando una medida de fuerza para un resultado. El Índice de Fragilidad representa el número de eventos consecutivos que es necesario añadir a un resultado dicotómico para que el hallazgo deje de ser significativo. Un número pequeño representa un hallazgo más débil y un número grande un hallazgo más fuerte.

¿Por qué se necesitaba ahora este estudio?

Femoral neck fractures in the elderly can be treated with internal fixation, hemiarthroplasty (HA) or total hip replacement (THR), depending on the patient's age and their ability to cope with surgery. Previous studies have established certain disadvantages for these treatment methods, with THR being associated with higher intra-operative blood loss and increased incidence of dislocation, and HA being associated with higher incidence rates of acetabular erosion. In order to accommodate these drawbacks, a new treatment consisting of a large metal femoral head coupled with a pliable, 2.7 mm thick hydrophilic polycarbonate-urethane (PCU) acetabular component was proposed. The present study aimed to compare the effectiveness of the PCU-THR treatment versus bilateral hemiarthroplasty in elderly patients suffering from femoral neck fractures.

¿Cuál era la pregunta principal de la investigación?

Did total hip replacement surgery with a polycarbonate-urethane (PCU) acetabular component improve function compared to hemiarthroplasty in elderly patients with femoral neck fractures 3 years post-treatment?

Características del estudio +
Población:
96 patients aged 70 years or older who suffered a Garden type III or IV displaced intracapsular femoral neck fracture (32 remaining at final follow-up).
Intervención:
PCU-THR group: Patients in this group underwent a total hip replacement (THR) using an uncemented Conus stem and a large-diameter femoral head, coupled with the PCU component and a 6 mm smaller-diameter metal head (47 patients randomized, 16 available at final follow-up). Mean age = 82.3 years (range 71-96), 19% male.
Comparación:
HA group: Based on surgeon preference, patients in this group underwent hemiarthroplasty (HA) treatment using either a cemented (n=33) or uncemented (n=8) stem with a bipolar femoral head (49 patients randomized, 16 available at final follow-up). Mean age = 84.2 years (range 73-98), 32% male.
Resultados:
The primary outcome was function (assessed using the Harris Hip score). Secondary outcomes included complications, rates of revision, intraoperative blood loss, the need for blood transfusion and duration of surgery.
Métodos:
RCT: Single Center
Tiempo:
Harris Hip scores were assessed at 3 months and every year following surgery for 3 years.
¿Cuáles fueron los hallazgos importantes?
  • There was no difference between groups in post-operative hospital stay, operative blood loss or operating time (p>0.05).
  • No difference was found in total Harris Hip scores at 3 months (p=0.878), 1 year (p=0.466), 2 years (p=0.342) or 3 years (p=0.118).
  • For the pain subscore of the Harris Hip index, the PCU-THR group demonstrated significantly greater pain at 1 year (p=0.006) and 2 years (0.019) post-operation compared ot the HA group, there was no difference in this subscore between groups at 3 months (p=0.158) or 3 years (p=0.073).
  • For the function subscore of the Harris Hip index, there were no differences between groups at 3 months (p=0.471), 1 year (p=0.466), 2 years (p=0.853), or 3 years (p=0.417) post-operation.
  • At final follow-up, there was no difference between groups in heterotropic ossification (p=0.942).
  • 6 patients in the PCU-THR group underwent revision surgery and 1 patient in the same group is awaiting re-operation. The main cause for revision was dislocation or wear of the PCU cup. Revision surgery was not required for any of the patients in the HA group.
  • The three-year survival rate in the PCU-THR group was 0.841 (95% CI 0.680 to 0.926).
¿Qué es lo que más debo recordar?

There was no difference in function between treatment of femoral neck fractures in the elderly with a total hip replacement and a polycarbonate-urethane acetabular component (PCU-THR), versus a hemiarthroplasty (HA) procedure at 3 months, 1 year, 2 years and 3 years post-operation. Pain was significantly worse in the PCU-THR group at 1 and 2 years post-operation and there were also more revision surgeries required in the PCU-THR group (n=6) compared to the HA group (n=0).

¿Cómo afectará esto al cuidado de mis pacientes?

The results from this study suggest that the use of a polycarbonate-urethane acetabular component in total hip replacements is not recommended over a hemiarthroplasty procedure in the treatment of femoral neck fractures in the elderly. This finding should be approached with caution, however, due to the large loss to follow-up in this study. Functional results and complication rates should be evaluated in larger studies to help guide treatment in this area.

DESCARGO DE RESPONSABILIDAD

El contenido de esta página tiene únicamente fines informativos y no pretende sustituir el consejo, diagnóstico o tratamiento médico profesional. Si necesita tratamiento médico, busque siempre el consejo de su médico o acuda al servicio de urgencias más cercano. Las opiniones, creencias y puntos de vista expresados por las personas sobre el contenido que se encuentra en esta página no reflejan las opiniones, creencias y puntos de vista de OrthoEvidence.

0 de 4 artículos mensuales GRATIS desbloqueados
Ha alcanzado su límite de vistas de 4 artículos gratuitos este mes

Acceda a OrtoEvidencia por tan sólo 1,99 $ a la semana.

Manténgase conectado con las últimas pruebas. Cancele en cualquier momento.
  • Valoraciones críticas de los últimos ensayos controlados aleatorizados de gran impacto y revisiones sistemáticas en ortopedia
  • Acceso al contenido del podcast OrthoEvidence, que incluye colaboraciones con el Journal of Bone and Joint Surgery, entrevistas con cirujanos reconocidos internacionalmente y mesas redondas sobre noticias y temas ortopédicos
  • Suscripción a The Pulse, un boletín quincenal basado en la evidencia y diseñado para ayudarle a tomar mejores decisiones clínicas
Upgrade
Close Dialog
Bienvenido
¿Ha olvidado su contraseña?
Comience hoy mismo su prueba GRATUITA

Su cuenta estará afiliada a
e incluye acceso gratuito a OrthoEvidence


O
¿Olvidó su contraseña?

O
Compruebe su correo electrónico

Si existe una cuenta con la dirección de correo electrónico proporcionada, se le enviará un correo electrónico para restablecer la contraseña. Si no ve el correo electrónico, compruebe su carpeta de correo no deseado o spam.

Si necesita más ayuda póngase en contacto con nuestro equipo de asistencia.

Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Traducir Informe ACE

OrthoEvidence utiliza un servicio de traducción de terceros para que el contenido sea accesible en varios idiomas. Tenga en cuenta que, aunque se hace todo lo posible para garantizar la exactitud, las traducciones no siempre son perfectas.

Cómo citar esto ACE Report

OrthoEvidence. Femoral neck fractures: Similar function, but higher revision rates using PCU-THR vs HA. OE Journal. 2013;1(10):6. Available from: https://myorthoevidence.com/AceReport/Show/femoral-neck-fractures-similar-function-but-higher-revision-rates-using-pcu-thr-vs-ha

Copiar cita
Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Función de miembro Premium

Para acceder a esta función, debe iniciar sesión en una cuenta Premium de OrthoEvidence.

Compartir ACE Report