ARTHROPLASTY
Femoral neck fractures: Similar function, but higher revision rates using PCU-THR vs HA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(10):6 Bone Joint J. 2013 May;95-B(5):609-15. doi: 10.1302/0301-620X.95B5.31083

96 patients aged 70 or over who had suffered femoral neck fractures (32 at final follow-up) were randomized to receive either a total hip replacement with a polycarbonate-urethane acetabular component (PCU-THR), or a hemiarthroplasty (HA) treatment. The purpose of this study was to evaluate the functional outcomes associated with these two treatments. Results indicated that there was no difference in function at 3 months, 1 year, 2 years or 3 years post-operation and that pain was worse in the PCU-THR group at 1 and 2 years. Lastly, higher revision rates were observed in the PCU-THR group.


Publication Funding Details +
Funding:
Not Reported
Conflicts:
None disclosed

Risk of Bias

3.5/10

Reporting Criteria

17/20

Fragility Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Yes = 1

Uncertain = 0.5

Not Relevant = 0

No = 0

The Reporting Criteria Assessment evaluates the transparency with which authors report the methodological and trial characteristics of the trial within the publication. The assessment is divided into five categories which are presented below.

3/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

The Fragility Index is a tool that aids in the interpretation of significant findings, providing a measure of strength for a result. The Fragility Index represents the number of consecutive events that need to be added to a dichotomous outcome to make the finding no longer significant. A small number represents a weaker finding and a large number represents a stronger finding.

Why was this study needed now?

Femoral neck fractures in the elderly can be treated with internal fixation, hemiarthroplasty (HA) or total hip replacement (THR), depending on the patient's age and their ability to cope with surgery. Previous studies have established certain disadvantages for these treatment methods, with THR being associated with higher intra-operative blood loss and increased incidence of dislocation, and HA being associated with higher incidence rates of acetabular erosion. In order to accommodate these drawbacks, a new treatment consisting of a large metal femoral head coupled with a pliable, 2.7 mm thick hydrophilic polycarbonate-urethane (PCU) acetabular component was proposed. The present study aimed to compare the effectiveness of the PCU-THR treatment versus bilateral hemiarthroplasty in elderly patients suffering from femoral neck fractures.

What was the principal research question?

Did total hip replacement surgery with a polycarbonate-urethane (PCU) acetabular component improve function compared to hemiarthroplasty in elderly patients with femoral neck fractures 3 years post-treatment?

Study Characteristics +
Population:
96 patients aged 70 years or older who suffered a Garden type III or IV displaced intracapsular femoral neck fracture (32 remaining at final follow-up).
Intervention:
PCU-THR group: Patients in this group underwent a total hip replacement (THR) using an uncemented Conus stem and a large-diameter femoral head, coupled with the PCU component and a 6 mm smaller-diameter metal head (47 patients randomized, 16 available at final follow-up). Mean age = 82.3 years (range 71-96), 19% male.
Comparison:
HA group: Based on surgeon preference, patients in this group underwent hemiarthroplasty (HA) treatment using either a cemented (n=33) or uncemented (n=8) stem with a bipolar femoral head (49 patients randomized, 16 available at final follow-up). Mean age = 84.2 years (range 73-98), 32% male.
Outcomes:
The primary outcome was function (assessed using the Harris Hip score). Secondary outcomes included complications, rates of revision, intraoperative blood loss, the need for blood transfusion and duration of surgery.
Methods:
RCT: Single Center
Time:
Harris Hip scores were assessed at 3 months and every year following surgery for 3 years.
What were the important findings?
  • There was no difference between groups in post-operative hospital stay, operative blood loss or operating time (p>0.05).
  • No difference was found in total Harris Hip scores at 3 months (p=0.878), 1 year (p=0.466), 2 years (p=0.342) or 3 years (p=0.118).
  • For the pain subscore of the Harris Hip index, the PCU-THR group demonstrated significantly greater pain at 1 year (p=0.006) and 2 years (0.019) post-operation compared ot the HA group, there was no difference in this subscore between groups at 3 months (p=0.158) or 3 years (p=0.073).
  • For the function subscore of the Harris Hip index, there were no differences between groups at 3 months (p=0.471), 1 year (p=0.466), 2 years (p=0.853), or 3 years (p=0.417) post-operation.
  • At final follow-up, there was no difference between groups in heterotropic ossification (p=0.942).
  • 6 patients in the PCU-THR group underwent revision surgery and 1 patient in the same group is awaiting re-operation. The main cause for revision was dislocation or wear of the PCU cup. Revision surgery was not required for any of the patients in the HA group.
  • The three-year survival rate in the PCU-THR group was 0.841 (95% CI 0.680 to 0.926).
What should I remember most?

There was no difference in function between treatment of femoral neck fractures in the elderly with a total hip replacement and a polycarbonate-urethane acetabular component (PCU-THR), versus a hemiarthroplasty (HA) procedure at 3 months, 1 year, 2 years and 3 years post-operation. Pain was significantly worse in the PCU-THR group at 1 and 2 years post-operation and there were also more revision surgeries required in the PCU-THR group (n=6) compared to the HA group (n=0).

How will this affect the care of my patients?

The results from this study suggest that the use of a polycarbonate-urethane acetabular component in total hip replacements is not recommended over a hemiarthroplasty procedure in the treatment of femoral neck fractures in the elderly. This finding should be approached with caution, however, due to the large loss to follow-up in this study. Functional results and complication rates should be evaluated in larger studies to help guide treatment in this area.

DISCLAIMER

This content found on this page is for informational purposes only and is not intended to be a substitute for professional medical advice, diagnosis, or treatment. If you require medical treatment, always seek the advice of your physician or go to your nearest emergency department. The opinions, beliefs, and viewpoints expressed by the individuals on the content found on this page do not reflect the opinions, beliefs, and viewpoints of OrthoEvidence.

0 of 4 monthly FREE articles unlocked
You've reached your limit of 4 free articles views this month

Access to OrthoEvidence for as little as $1.99 per week.

Stay connected with latest evidence. Cancel at any time.
  • Critical appraisals of the latest, high-impact randomized controlled trials and systematic reviews in orthopaedics
  • Access to OrthoEvidence podcast content, including collaborations with the Journal of Bone and Joint Surgery, interviews with internationally recognized surgeons, and roundtable discussions on orthopaedic news and topics
  • Subscription to The Pulse, a twice-weekly evidence-based newsletter designed to help you make better clinical decisions
Upgrade
Welcome Back!
Forgot Password?
Start your FREE trial today!

Your account will be affiliated with
and includes free access to OrthoEvidence


OR
Forgot Password?

OR
Please check your email

If an account exists with the provided email address, a password reset email will be sent to you. If you don't see an email, please check your spam or junk folder.

For further assistance, contact our support team.

Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Translate ACE Report

OrthoEvidence utilizes a third-party translation service to make content accessible in multiple languages. Please note that while every effort is made to ensure accuracy, translations may not always be perfect.

How to cite this ACE Report

OrthoEvidence. Femoral neck fractures: Similar function, but higher revision rates using PCU-THR vs HA. OE Journal. 2013;1(10):6. Available from: https://myorthoevidence.com/AceReport/Show/femoral-neck-fractures-similar-function-but-higher-revision-rates-using-pcu-thr-vs-ha

Copy Citation
Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Premium Member Feature

To access this feature, you must be logged into a premium OrthoEvidence account.

Share this ACE Report