Femoral neck fractures: Similar function, but higher revision rates using PCU-THR vs HA .
This report has been verified
by one or more authors of the
original publication.
A comparison of hemiarthroplasty with a novel polycarbonate-urethane acetabular component for displaced intracapsular fractures of the femoral neck: A randomised controlled trial in elderly patients
Bone Joint J. 2013 May;95-B(5):609-15. doi: 10.1302/0301-620X.95B5.3108396 patients aged 70 or over who had suffered femoral neck fractures (32 at final follow-up) were randomized to receive either a total hip replacement with a polycarbonate-urethane acetabular component (PCU-THR), or a hemiarthroplasty (HA) treatment. The purpose of this study was to evaluate the functional outcomes associated with these two treatments. Results indicated that there was no difference in function at 3 months, 1 year, 2 years or 3 years post-operation and that pain was worse in the PCU-THR group at 1 and 2 years. Lastly, higher revision rates were observed in the PCU-THR group.
Unlock the Full ACE Report
You have access to 4 more FREE articles this month.
Click below to unlock and view this ACE Reports
Unlock Now
Critical appraisals of the latest, high-impact randomized controlled trials and systematic reviews in orthopaedics
Access to OrthoEvidence podcast content, including collaborations with the Journal of Bone and Joint Surgery, interviews with internationally recognized surgeons, and roundtable discussions on orthopaedic news and topics
Subscription to The Pulse, a twice-weekly evidence-based newsletter designed to help you make better clinical decisions
Exclusive access to original content articles, including in-house systematic reviews, and articles on health research methods and hot orthopaedic topics