SPINE
Ultrasound-guided versus Computed Tomography-controlled facet joint injections in the middle and lower cervical spine: a prospective randomized clinical trial
This report has been verified
by one or more authors of the
original publication.
OrthoEvidence Journal (OE Journal) - ACE Report
OE Journal. 2013;1(6):94 Med Ultrason. 2013 Mar;1540 patients were randomized to assess the safety and efficacy of ultrasound-guided (US) facet joint injections in the cervical spine. Patients received either US-guided facet joint injections or computer tomography (CT)-guided instillations and were assessed after 4 weeks. Results indicated that the US-guided procedure led to same therapeutic effects as CT-guided techniques; moreover, US-guided injections displayed a greater reduction in procedure duration and exposure to radiation.