TKR: No difference between all-polyethylene and metal-backed tibial implants .
Should we reconsider all-polyethylene tibial implants in total knee replacement?
J Bone Joint Surg Br. 2006 Dec;88(12):1596-60251 patients with osteoarthritis or rheumatoid arthritis were randomized to receive total knee replacement (TKR) with either all-polyethylene or metal-backed tibial implants. Over 2 years, radiostereophotogrammetric analysis indicated that there was no difference between the two groups in the migration of prostheses. The two groups also did not differ in their SF-12, Oxford knee scores, alignment or range of motion. It was therefore concluded that there is no advantage of the metal-backed implants over all-polyethylene tibial implants in TKR.
Vollständigen ACE-Bericht freischalten
Sie haben Zugang zu 4 weiteren KOSTENLOSEN Artikeln in diesem Monat.
Klicken Sie unten, um diese ACE Reports freizuschalten und anzusehen
Jetzt freischalten
Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Exklusiver Zugang zu Originalartikeln, einschließlich eigener systematischer Übersichten, sowie zu Artikeln über Methoden der Gesundheitsforschung und aktuelle orthopädische Themen