ACE Report Cover
TKA: No effect of fibrin sealant on reducing blood loss and functional recovery
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
ARTHROPLASTY
TKA: No effect of fibrin sealant on reducing blood loss and functional recovery .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(8):6 Acta Orthop. 2013 Apr;84(2):153-8. doi: 10.3109/17453674.2013.769082. Epub 2013 Jan 25
المؤلفون المساهمون

C Skovgaard B Holm A Troelsen TH Lunn L Gaarn-Larsen H Kehlet H Husted

24 patients (48 knees) undergoing simultaneous bilateral total knee arthroplasty (TKA) had their knees 1:1 randomized to receive an intraoperative application of either fibrin sealant or saline. The purpose was to determine the adjuvant effect of fibrin sealant on postoperative blood loss in patients already treated with preoperative tranexamic acid and tourniquet use. Blood loss was calculated 24 hours following surgery, and patients were assessed for functional recovery up to 21 days postoperatively. The findings indicated that there was no decrease in blood loss in knees treated with fibrin sealant, and that pain, swelling, range of motion, and isokinetic strength was similar between knees, regardless of the application of fibrin sealant or saline.


تفاصيل تمويل المنشور +
التمويل:
Industry funded
الراعي:
Johnson and Johnson Medical Ltd.
Conflicts:
None disclosed

مخاطر التحيز

8٫5/10

معايير الإبلاغ

17/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Randomization

3/4

Outcome Measurements

2/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Postoperative blood loss following total knee arthroplasty (TKA) may be associated with significant morbidity and impaired functional recovery. There have been many developments in stemming blood loss following surgery, one of which is a topical application of fibrin sealant. While the hemostatic agent has been investigated in prior studies, there is limited evidence of its effect as an adjunct to other blood loss regimens (ie. tranexamic acid, intramedullary femoral canal plugging), as well as its effect on functional recovery.

ما هو سؤال البحث الرئيسي؟

What is the effect of adjuvant fibrin sealant on postoperative blood loss and early functional recovery following total knee arthroplasty, with blood loss measured within the first 24 postoperative hours and function assessed up to 21 days postoperatively?

خصائص الدراسة +
Population:
24 patients (n=48 knees) undergoing simultaneous bilateral total knee arthroplasty. All patients were given preoperative cefuroxime (1.5g intravenously) and tranexamic acid (0.5g 10 min prior to tourniquet inflation (100mmHg above systolic pressure) on the first knee, followed by 0.5g after deflation and before inflation on the second knee), and were operated on with a medial parapatellar approach. Closure of the femoral canal was achieved with an autologous bone plug, and one intra-articular drain (passive) was installed in each knee. Patients either received AGC or Vanguard ROCC (Biomet) prostheses. (Mean age: 65 years)
Intervention:
Fibrin sealant group: After implantation of the knee prosthesis, and while the tourniquet was still inflated, 10mL of fibrin sealant (Evicel) was sprayed onto all instrumented cut surfaces and soft tissues. (n=24 knees)
Comparison:
Control group: After implantation of the knee prosthesis, and while the tourniquet was still inflated, 10mL of saline was sprayed onto all instrumented cut surfaces and soft tissues. (n=24 knees)
Outcomes:
Primary outcome was blood loss within the first 24h postoperatively, measured by drain output. Secondary outcomes included pain on a visual analog scale (VAS), knee swelling measured by knee circumference (1cm proximal to patella), knee range of motion (ROM) using a goniometer, and isometric knee strength.
Methods:
RCT, Double-blind, Placebo-controlled, Single-centre
Time:
Blood loss was measured at 24h postoperatively. Knee pain and swelling were assessed daily until postoperative day (POD) 3, then again at POD 7 and 21. ROM and strength assessment was conducted at POD 3, 7, and 21.
ما هي النتائج المهمة؟
  • Mean blood loss calculated from drains at 24h postoperatively was 582mL (SD 328mL) for knees allocated to the fibrin sealant and 576mL (SD 289mL) in knees treated with saline (p=0.9).
  • There was no significant difference in pain between groups either at rest or during flexion at any time-point (all p>0.05).
  • Knee swelling did not significantly differ between groups at any assessment (p>0.05).
  • ROM assessment of both flexion and extension were observed to be similar between groups at each time point, with no significant differences being observed (all P>0.05).
  • Isometric knee strength was similarly reduced from baseline at day 3 assessment in both groups, with gradual recovery. Recovery by day 21 was still lower that preoperative values. There were no significant differences between groups at any of the assessments (all P>0.05).
ما الذي يجب أن أتذكره أكثر؟

The use of the fibrin sealant, Evicel, in total knee arthroplasty did not reduce blood loss, nor promote any benefit in functional recovery when compared to placebo treatment with saline in the contralateral knee.

كيف سيؤثر ذلك على رعاية مرضاي؟

The results of the present study do not support the application of adjuvant fibrin sealant as a means to stem postoperative blood loss following total knee arthroplasty. However, there was concern that hyperemia caused by the deflation of the tourniquet may have flushed out the fibrin sealant prior to eliciting any potential effect. It may be worthwhile to determine if there is an effect of Evicel in the absence of tourniquet use.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. TKA: No effect of fibrin sealant on reducing blood loss and functional recovery. OE Journal. 2013;1(8):6. Available from: https://myorthoevidence.com/AceReport/Show/tka-no-effect-of-fibrin-sealant-on-reducing-blood-loss-and-functional-recovery

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report