ARTHROPLASTY

TKA: Better implant stability but comparable functionality with HA-coated tibial implants .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(11):32 Acta Orthop. 2011 Aug;82(4):448-59. Epub 2011 Jun 10

Autores contribuintes

JD Voigt M Mosier

This systematic review and meta-analysis identified 14 trials, which included 926 evaluable total knee arthroplasties. These studies examined the effect of hydroxyapatite (HA)-coating on tibial implant durability in primary total knee arthroplasty (TKA), in comparison other forms of tibial fixation. The primary outcomes in the selected studies were durability, function, and acute adverse events. Results indicated that the functionality between the types of implants were comparable, but durability with the HA-coated tibial implant may be better than other tibial implants in patients >65 years. There were no differences in adverse events between HA coated implants and other forms of tibial fixation.


Detalhes do financiamento da publicação +
Financiamento:
Not Reported
Conflitos:
None disclosed

Risco de viés

9/10

Critérios de notificação

18/20

Índice de Fragilidade

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

4/4

Introduction

3/4

Accessing Data

4/4

Analysing Data

4/4

Results

3/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

There is uncertainty on the clinical benefits of hydroxyapatite (HA)-coating in tibial components, as a part of total knee arthroplasty. HA-coatings on implants may promote greater stable fixation due to its osteoconductive properties, which promote early bone in-growth. This meta-analysis was conducted to evaluate the clinical outcomes (durability, function, and acute adverse events) in HA-coated tibial components in total knee arthroplasties.

Qual era a principal questão de investigação?

What are the clinical outcomes (durability, function, and acute adverse events) of hydroxyapatite (HA)-coated tibial components compared to other forms of tibial fixation in patients with knee osteoarthritis undergoing primary total knee arthroplasty measured at both short and long-term follow-up periods?

Caraterísticas do estudo +
Fonte de dados:
A search was conducted for published, prospective randomised controlled trials between 1990 to September 16, 2010 from internet databases and hand searches. Details of the literature search are not provided in the journal article, but is available on the Acta Orthopaedica website.
Termos do índice:
Not listed.
Seleção do estudo:
Studies included were prospective randomised trials that examined the clinical outcomes (durability, function, and adverse events) of hydroxyapatite (HA)-coated tibial components or other tibial components (uncemented porous coated metal components, uncemented press-fit metal components, and cemented metal components (porous and non-porous coated)) in the shorter and longer terms. Two authors (JV and MM) screened the studies, and one author (JV) assessed the studies based on pre-specified inclusion/exclusion criteria.
Extração de dados:
Identified studies had data independently extracted by one author (JV) and reviewed by another author (MM). Discrepancies were resolved through discussion or adjudication by an independent third party.
Síntese de dados:
Data was assembled and reviewed using the Cochrane Review Manager software version 5.0.2. Random and fixed effects models were used, and heterogeneity was calculated using the I^squared statistic. Dichotomous outcomes were expressed as risk ratios (RR) with corresponding 95% confidence intervals (CI's), and continuous outcomes were expressed as mean differences.
Quais foram os resultados importantes?
  • At 2 years, tibial components coated with hydroxyapatite (HA) (porous or press-fit) without screw fixation were less likely to be unstable, compared to cemented and porous metal-backed tibial components (RR=0.58, 95%CI: 0.34-0.98; p=0.04, I2 = 39%, M-H random effects model)
  • No significant difference was seen in adverse events between groups (RR=1.20, 95%CI: 0.63-2.28; p=0.58; I2 =0%; Mantel-Haenszel (M-H) fixed effects model)
  • Evaluation at 2, and 8-10 years indicated no significant difference in durability between groups.
  • No significant difference was seen in functional status at 2 and 5 years, regardless of the type of measure used.
De que é que me devo lembrar mais?

Hydroxyapatite (HA)-coated implants may provide better implant stability in patients with osteoarthritis undergoing primary total knee arthroplasty (TKA), who are within the age range of 65-70 years, which may lead to a reduction in the need for revision later in the implant life. No difference was apparent in functionality between the HA-coated and other tibial implants, when measured by different validated scoring systems. No significant difference was seen in adverse events between groups.

Como é que isto afectará o tratamento dos meus doentes?

Trials with a larger population should be performed to determine the long-term outcomes of HA-coated implants and other porous-coated tibial implants, in younger (<65 years) and more active individuals with osteoarthritis.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Close Dialog
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. TKA: Better implant stability but comparable functionality with HA-coated tibial implants. OE Journal. 2013;1(11):32. Available from: https://myorthoevidence.com/AceReport/Show/tka-better-implant-stability-but-comparable-functionality-with-ha-coated-tibial-implants

Copie a citação
Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Funcionalidade de Membro Premium

Para aceder a esta funcionalidade, tem de ter sessão iniciada numa conta Premium da OrthoEvidence.

Partilhe isto ACE Report