ACE Report Cover
TKA: Better implant stability but comparable functionality with HA-coated tibial implants
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descargar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descargar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
ARTHROPLASTY
TKA: Better implant stability but comparable functionality with HA-coated tibial implants .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(11):32 Acta Orthop. 2011 Aug;82(4):448-59. Epub 2011 Jun 10
Autores colaboradores

JD Voigt M Mosier

This systematic review and meta-analysis identified 14 trials, which included 926 evaluable total knee arthroplasties. These studies examined the effect of hydroxyapatite (HA)-coating on tibial implant durability in primary total knee arthroplasty (TKA), in comparison other forms of tibial fixation. The primary outcomes in the selected studies were durability, function, and acute adverse events. Results indicated that the functionality between the types of implants were comparable, but durability with the HA-coated tibial implant may be better than other tibial implants in patients >65 years. There were no differences in adverse events between HA coated implants and other forms of tibial fixation.


Detalles de la financiación de la publicación +
Financiación:
Not Reported
Conflictos:
None disclosed

Riesgo de sesgo

9/10

Criterios de información

18/20

Índice de fragilidad

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

Sí = 1

Incierto = 0,5

No relevante = 0

No = 0

La evaluación de los criterios de información evalúa la transparencia con la que los autores informan de las características metodológicas y del ensayo dentro de la publicación. La evaluación se divide en cinco categorías que se presentan a continuación.

4/4

Introduction

3/4

Accessing Data

4/4

Analysing Data

4/4

Results

3/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

El Índice de Fragilidad es una herramienta que ayuda en la interpretación de hallazgos significativos, proporcionando una medida de fuerza para un resultado. El Índice de Fragilidad representa el número de eventos consecutivos que es necesario añadir a un resultado dicotómico para que el hallazgo deje de ser significativo. Un número pequeño representa un hallazgo más débil y un número grande un hallazgo más fuerte.

¿Por qué se necesitaba ahora este estudio?

There is uncertainty on the clinical benefits of hydroxyapatite (HA)-coating in tibial components, as a part of total knee arthroplasty. HA-coatings on implants may promote greater stable fixation due to its osteoconductive properties, which promote early bone in-growth. This meta-analysis was conducted to evaluate the clinical outcomes (durability, function, and acute adverse events) in HA-coated tibial components in total knee arthroplasties.

¿Cuál era la pregunta principal de la investigación?

What are the clinical outcomes (durability, function, and acute adverse events) of hydroxyapatite (HA)-coated tibial components compared to other forms of tibial fixation in patients with knee osteoarthritis undergoing primary total knee arthroplasty measured at both short and long-term follow-up periods?

Características del estudio +
Fuente de datos:
A search was conducted for published, prospective randomised controlled trials between 1990 to September 16, 2010 from internet databases and hand searches. Details of the literature search are not provided in the journal article, but is available on the Acta Orthopaedica website.
Términos del índice:
Not listed.
Selección de estudios:
Studies included were prospective randomised trials that examined the clinical outcomes (durability, function, and adverse events) of hydroxyapatite (HA)-coated tibial components or other tibial components (uncemented porous coated metal components, uncemented press-fit metal components, and cemented metal components (porous and non-porous coated)) in the shorter and longer terms. Two authors (JV and MM) screened the studies, and one author (JV) assessed the studies based on pre-specified inclusion/exclusion criteria.
Extracción de datos:
Identified studies had data independently extracted by one author (JV) and reviewed by another author (MM). Discrepancies were resolved through discussion or adjudication by an independent third party.
Síntesis de datos:
Data was assembled and reviewed using the Cochrane Review Manager software version 5.0.2. Random and fixed effects models were used, and heterogeneity was calculated using the I^squared statistic. Dichotomous outcomes were expressed as risk ratios (RR) with corresponding 95% confidence intervals (CI's), and continuous outcomes were expressed as mean differences.
¿Cuáles fueron los hallazgos importantes?
  • At 2 years, tibial components coated with hydroxyapatite (HA) (porous or press-fit) without screw fixation were less likely to be unstable, compared to cemented and porous metal-backed tibial components (RR=0.58, 95%CI: 0.34-0.98; p=0.04, I2 = 39%, M-H random effects model)
  • No significant difference was seen in adverse events between groups (RR=1.20, 95%CI: 0.63-2.28; p=0.58; I2 =0%; Mantel-Haenszel (M-H) fixed effects model)
  • Evaluation at 2, and 8-10 years indicated no significant difference in durability between groups.
  • No significant difference was seen in functional status at 2 and 5 years, regardless of the type of measure used.
¿Qué es lo que más debo recordar?

Hydroxyapatite (HA)-coated implants may provide better implant stability in patients with osteoarthritis undergoing primary total knee arthroplasty (TKA), who are within the age range of 65-70 years, which may lead to a reduction in the need for revision later in the implant life. No difference was apparent in functionality between the HA-coated and other tibial implants, when measured by different validated scoring systems. No significant difference was seen in adverse events between groups.

¿Cómo afectará esto al cuidado de mis pacientes?

Trials with a larger population should be performed to determine the long-term outcomes of HA-coated implants and other porous-coated tibial implants, in younger (<65 years) and more active individuals with osteoarthritis.

DESCARGO DE RESPONSABILIDAD

El contenido de esta página tiene únicamente fines informativos y no pretende sustituir el consejo, diagnóstico o tratamiento médico profesional. Si necesita tratamiento médico, busque siempre el consejo de su médico o acuda al servicio de urgencias más cercano. Las opiniones, creencias y puntos de vista expresados por las personas sobre el contenido que se encuentra en esta página no reflejan las opiniones, creencias y puntos de vista de OrthoEvidence.

0 de 4 artículos mensuales GRATIS desbloqueados
Ha alcanzado su límite de vistas de 4 artículos gratuitos este mes

Acceda a OrtoEvidencia por tan sólo 1,99 $ a la semana.

Manténgase conectado con las últimas pruebas. Cancele en cualquier momento.
  • Valoraciones críticas de los últimos ensayos controlados aleatorizados de gran impacto y revisiones sistemáticas en ortopedia
  • Acceso al contenido del podcast OrthoEvidence, que incluye colaboraciones con el Journal of Bone and Joint Surgery, entrevistas con cirujanos reconocidos internacionalmente y mesas redondas sobre noticias y temas ortopédicos
  • Suscripción a The Pulse, un boletín quincenal basado en la evidencia y diseñado para ayudarle a tomar mejores decisiones clínicas
Upgrade
Close Dialog
Bienvenido
¿Ha olvidado su contraseña?
Comience hoy mismo su prueba GRATUITA

Su cuenta estará afiliada a
e incluye acceso gratuito a OrthoEvidence


O
¿Olvidó su contraseña?

O
Compruebe su correo electrónico

Si existe una cuenta con la dirección de correo electrónico proporcionada, se le enviará un correo electrónico para restablecer la contraseña. Si no ve el correo electrónico, compruebe su carpeta de correo no deseado o spam.

Si necesita más ayuda póngase en contacto con nuestro equipo de asistencia.

Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Traducir Informe ACE

OrthoEvidence utiliza un servicio de traducción de terceros para que el contenido sea accesible en varios idiomas. Tenga en cuenta que, aunque se hace todo lo posible para garantizar la exactitud, las traducciones no siempre son perfectas.

Cómo citar esto ACE Report

OrthoEvidence. TKA: Better implant stability but comparable functionality with HA-coated tibial implants. OE Journal. 2013;1(11):32. Available from: https://myorthoevidence.com/AceReport/Show/tka-better-implant-stability-but-comparable-functionality-with-ha-coated-tibial-implants

Copiar cita
Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Función de miembro Premium

Para acceder a esta función, debe iniciar sesión en una cuenta Premium de OrthoEvidence.

Compartir ACE Report