Potentially lower migration with all-poly vs metal-backed tibia component in total knee arthroplasty .
This report has been verified
by one or more authors of the
original publication.
Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty
Acta Orthop. 2018 Aug;89(4):412-417. doi: 10.1080/17453674.2018.146431760 patients scheduled for total knee arthroplasty were randomized to either an all-polyethylene tibial component or metal-backed tibial component. Primary outcome was maximum total point motion of the tibial component over 2-year follow-up, while clinical scores and incidence of adverse events were secondary outcomes. Two-year maximum total point motion of the tibial component was significantly lower in the All-Poly group compared to the Metal-Backed group. Clinical scores, including the Knee Injury and Osteoarthritis Outcome Score, Knee Society Score, and the Forgotten Joint Score, did not significantly differ between groups after 2 years.
افتح تقرير ACE الكامل
لديك إمكانية الوصول إلى المزيد من المقالات المجانية هذا الشهر، انقر أدناه لفتح هذا ACE Reports
افتح الآنتقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في جراحة العظام
الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، ومقابلات مع جراحين معترف بهم دوليًا، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
الاشتراك في النشرة الإخبارية The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك في اتخاذ قرارات سريرية أفضل
إمكانية الوصول الحصري إلى مقالات المحتوى الأصلي، بما في ذلك المراجعات المنهجية الداخلية، ومقالات عن طرق البحث الصحي وموضوعات جراحة العظام الساخنة