ARTHROPLASTY
Patient-specific vs. conventional instrumentation TKA: similar effect on implant rotation .
Verified
This report has been verified by one or more authors of the original publication.
High Impact
تم تحديد هذه الدراسة على أنها ذات تأثير كبير محتمل. يُقدّر مقياس التأثير العالي الذي يعتمد على الذكاء الاصطناعي من OE التأثير المحتمل لورقة بحثية ما من خلال دمج الإشارات من كل من المجلة التي نُشرت فيها والمحتوى العلمي للمقالة نفسها. تم تطوير نموذج OE High Impact باستخدام أحدث تقنيات معالجة اللغة الطبيعية، ويتنبأ نموذج OE High Impact بدقة أكبر بأداء الاقتباس المستقبلي للدراسة أكثر من معامل تأثير المجلة وحده. وهذا يتيح التعرف المبكر على الأبحاث ذات المغزى السريري ويساعد القراء على التركيز على المقالات التي من المرجح أن تشكل الممارسة المستقبلية.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(1):6 Knee Surg Sports Traumatol Arthrosc. 2013 Oct;21(10):2213-9
المؤلفون المساهمون

S Parratte G Blanc T Boussemart M Ollivier T Le Corroller JN Argenson

40 patients, between the ages of 50 and 85, who were unresponsive to conservative treatment and were scheduled to receive total knee arthroplasty (TKA), were randomly assigned into 1 of 2 groups to test the effect of patient-specific instrumentation (PSI) on accuracy and rotational alignment in TKA. Patients received treatment with PSI or through a conventional TKA. Results indicated that PSI did not have a significant effect on the rotational alignment in patients following TKA.


تفاصيل تمويل المنشور +
التمويل:
Not Reported
التعارضات:
None disclosed

مخاطر التحيز

6٫5/10

معايير الإبلاغ

16/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

3/4

Randomization

4/4

Outcome Measurements

2/4

Inclusion / Exclusion

4/4

Therapy Description

3/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Implant malposition has been reported to be as high as 20-40% when using conventional instrumentation in total knee arthroplasty. To reduce the likelihood of implant malposition patient-specific instrumentation (PSI) was introduced with the goal of improving implant positioning and reducing the overall cost and surgery time needed to complete the procedure. Previous studies have shown that PSI can successfully restore the mechanical axis, but very little information has been gathered regarding the role of PSI in the rotation of the tibial and femoral implants. This study was brought forward to assess the matching of preoperative planning and postoperative position of the TKA implants, and to closely analyze the femoral rotation of implants positioned with or without PSI.

ما هو سؤال البحث الرئيسي؟

Does the use of patient-specific instruments improve the accuracy of the rotational alignment in TKA?

خصائص الدراسة +
Population:
40 patients, between the ages of 50 and 85, who had failed nonoperative intervention and who were scheduled to receive total knee arthroplasty
Intervention:
PSI Group: Patients in this group received an MRI 6-8 weeks prior to the surgery. The MRI included image acquisition on the hip and knee (between 80 and 120 cuts) and on the angle). Following segmentation, a group of engineers performed the planning of the TKA and submitted it to the participating surgeon. Based on clinical examination and on standing full-length X-rays, an edition of the planning was performed by the surgeon concerning the depth of the distal femoral and tibial cuts. Following the edition, the extension spaces were checked and planning approved. Rapid-prototyping, computer assisted, technology created the PSI jigs and a PSI guide was carefully positioned over the articular surface. A standard TKA procedure was then performed. All patients received the same high-flex mobile bearing TKA (NexGen LPS-Flex mobile, Zimmer, Warsaw) (n=20).
Comparison:
Control Group: Patients in this group were operated according to a previously described technique using an extra-medullary guide for the tibia and intra-medullary guide for the femur. All patients received the same high-flex mobile bearing TKA (NexGen LPS-Flex mobile, Zimmer, Warsaw) (n=20).
Outcomes:
Outcomes assessed were obtained through: X-ray and CT-scan results, which were used to calculate the three-dimensional angle of the implants. Rotation and alignment following treatment were also analyzed.
Methods:
RCT: Single Center: Single Blinded
Time:
Radiological assessments and CT-Scans were performed 3 days after surgery completion, and weight-bearing full-length X rays were performed 3 months after treatment
ما هي النتائج المهمة؟
  • Patients in the PSI group experienced <2 degrees or mm of difference between the planned position of the femoral implant and the obtained position in all femoral measurements except distal cut flexion angle (Mean difference of 2.6 degrees, 95% CI= 0.9)
  • Patients in the PSI group experienced <2 degrees of difference between the planned position of the tibial implant and the obtained position when analyzing average tibial proximal cut (1.2 degrees), but not when looking at mean tibial slope angle (Mean difference of 2.2 degrees, 95% CI= 0.8), and tibial rotation (Mean difference of 6.8 degrees, 95% CI= 2.1).
  • A total of 90% of all patients in the PSI group experienced less than 2 degrees or less than 2 mm of difference between the planned position of the femoral and tibial implants and their obtained positions, expect for when measuring tibial rotation, where the variations were much higher.
  • No difference was observed between the two groups when analyzing weight-bearing full length X-rays 3 months after surgery. Mean HKA was 179 degrees in the PSI group with 4 outliers compared to 178.3 degrees with 2 outliers in the control group (p>0.05).
  • No difference was found between the two groups concerning frontal and sagittal position of implants measured through Ml and AP X-rays (FFC, FTC, LFC, and LTC angle, and tibial slope, p>0.05 for all measurements).
  • No significant difference in femoral rotation was observed between the two groups with a mean of 0.4 degrees begin expressed in the PSI group compared to 0.2 degrees in the control group (p>0.05).
  • Mean tibial rotation was 8 degrees of internal rotation in the PSI group compared to 15 degrees of internal rotation in the control (p>0.05).
ما الذي يجب أن أتذكره أكثر؟

90% of all patients in the PSI group experienced less than 2 degrees or less than 2 mm of difference between the planned position of the femoral and tibial implants and their obtained positions, expect for when measuring tibial rotation, where the variations were much higher. No difference was observed between the two groups when analyzing weight-bearing full length X-rays 3 months after surgery or when concerning frontal and sagittal position of implants measured through Ml and AP X-rays. No difference in femoral rotation was found between the groups. Average tibial rotation was also similar between the two groups.

كيف سيؤثر ذلك على رعاية مرضاي؟

The results of this study indicate that PSI does not improve rotation/ rotational alignment in TKA. Further research must be completed on the topic of patient-specific instrumentation to fully understand the effect it has on outcomes following TKA.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
Close Dialog
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Patient-specific vs. conventional instrumentation TKA: similar effect on implant rotation. OE Journal. 2014;2(1):6. Available from: https://myorthoevidence.com/AceReport/Show/patient-specific-vs-conventional-instrumentation-tka-similar-effect-on-implant-rotation