ARTHROPLASTY
No difference in rate of malalignment between PSI and conventional instruments in TKA .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2018;6(11):2 Acta Orthop. 2018 Feb;89(1):89-94
Contributing Authors

F Snorrason SM Röhrl J Van Leeuwen

109 patients scheduled for total knee arthroplasty were randomized to surgery with either the use of patient-specific cutting guides or conventional intra- and extramedullary guides. Patients were assessed for overall lower limb alignment, femoral component alignment in the coronal, sagittal, and axial planes, tibial component alignment in the coronal and sagittal planes, and patient-reported outcome measures and knee range of motion over a 2-year follow-up. Results demonstrated no statistically significant differences between groups in the rate of outliers (>3deg deviation from planned alignment) in any alignment comparison, or in any patient-reported outcome measure or range of motion over a 2-year follow-up.


Publication Funding Details +
Funding:
Non-funded
Conflicts:
None disclosed

Risk of Bias

6.5/10

Reporting Criteria

16/21

Fragility Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Yes = 1

Uncertain = 0.5

Not Relevant = 0

No = 0

The Reporting Criteria Assessment evaluates the transparency with which authors report the methodological and trial characteristics of the trial within the publication. The assessment is divided into five categories which are presented below.

2/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/5

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

The Fragility Index is a tool that aids in the interpretation of significant findings, providing a measure of strength for a result. The Fragility Index represents the number of consecutive events that need to be added to a dichotomous outcome to make the finding no longer significant. A small number represents a weaker finding and a large number represents a stronger finding.

Why was this study needed now?

When first introduced, there was a lot of interest in patient-specific instruments as a method to potentially improve the alignment of components in total knee arthroplasty. As randomized controlled trials have been published on their use, mixed evidence in support of their efficacy has been reported. There is a continued need for high-quality studies on their use in order to determine their role in routine practice for total knee arthroplasty.

What was the principal research question?

In total knee arthroplasty, is there any significant difference in mean component alignment, the incidence of outliers in component alignment (>3deg deviation from planned alignment), or patient-reported outcome measures, over 2 years postoperatively between patient-specific instrumentation and convention instruments?

Study Characteristics +
Population:
109 patients scheduled for total knee arthroplasty due to knee osteoarthritis. All cases were completed using a medial parapatellar approach and the same cemented total knee implant (Vanguard Cruciate Retaining Knee; Biomet Inc.).
Intervention:
PSI group: Patient-specific cutting guides were manufactured from preoperative MRI scans, with femoral rotation set relative to the surgical epicondylar axis, femoral flexion set at 3 degrees, and tibial slope set at 3 degrees. (n=44; Mean age: 67+/-8.8)
Comparison:
CONV group: Femoral resection was aided with the use of a standard intramedullary guide, and tibial resection with a standard extramedullary guide. (n=50; Mean age: 64+/-6.9)
Outcomes:
Full weight-bearing radiographs were used to measure the hip-knee-ankle angle, while CT was used to measure the coronal angles of the tibial and femoral components, the sagittal angles of the tibial and femoral components, and axial alignment of the femoral component. Component outliers were defined as alignment exceeding 3-degree deviation from planned alignment. Clinical scores included the Knee Injury and Osteoarthritis Outcome Score (KOOS), pain on a numeric rating scale, and the EuroQol 5-dimensions health survey (EQ-5D). The range of motion was also measured.
Methods:
RCT; Multicenter (3 sites)
Time:
Imaging was performed at 3 months postoperatively. Clinical measures were assessed at 3 months, 1 year, and 2 years postoperatively.
What were the important findings?
  • The incidence of femoral outliers did not significantly differ between the PSI group and the CONV group in the coronal plane (7/43 vs. 4/47; p=0.3), sagittal plane (29/43 vs. 23/47; p=0.08), or axial plane (5/43 vs. 7/47; p=0.7).
  • The incidence of tibial outliers did not significantly differ between the PSI group and the CONV group in the coronal plane (8/43 vs. 3/47; p=0.08) or the sagittal plane (17/43 vs. 26/47; p=0.1).
  • The incidence of outliers in HKA angle (reference: neutral alignment) did not significantly differ between the PSI group and the CONV group (11/42 vs. 11/49; p=0.7).
  • No significant differences between the PSI group and the CONV group were observed in KOOS scores, NRS pain scores, EQ-5D scores, or knee range of motion in flexion and extension at 3 months, 1 year, or 2 years (all p>0.05).
What should I remember most?

In total knee arthroplasty, there were no significant differences between cases completed using patient-specific instruments and cases completed using standard intra- and extramedullary guides in rate of overall lower limb malalignment, rate of malalignment of either the femoral component or tibial component individually, or in patient-reported outcome measured and knee range of motion over 2 year follow-up.

How will this affect the care of my patients?

The results of this study suggest that there does not appear to be a clinical benefit to the use of patient-specific instruments over conventional instruments in completing total knee arthroplasties.

DISCLAIMER

This content found on this page is for informational purposes only and is not intended to be a substitute for professional medical advice, diagnosis, or treatment. If you require medical treatment, always seek the advice of your physician or go to your nearest emergency department. The opinions, beliefs, and viewpoints expressed by the individuals on the content found on this page do not reflect the opinions, beliefs, and viewpoints of OrthoEvidence.

0 of 4 monthly FREE articles unlocked
You've reached your limit of 4 free articles views this month

Access to OrthoEvidence for as little as $1.99 per week.

Stay connected with latest evidence. Cancel at any time.
  • Critical appraisals of the latest, high-impact randomized controlled trials and systematic reviews in orthopaedics
  • Access to OrthoEvidence podcast content, including collaborations with the Journal of Bone and Joint Surgery, interviews with internationally recognized surgeons, and roundtable discussions on orthopaedic news and topics
  • Subscription to The Pulse, a twice-weekly evidence-based newsletter designed to help you make better clinical decisions
Upgrade
Welcome Back!
Forgot Password?
Start your FREE trial today!

Your account will be affiliated with
and includes free access to OrthoEvidence


OR
Forgot Password?

OR
Please check your email

If an account exists with the provided email address, a password reset email will be sent to you. If you don't see an email, please check your spam or junk folder.

For further assistance, contact our support team.

Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Translate ACE Report

OrthoEvidence utilizes a third-party translation service to make content accessible in multiple languages. Please note that while every effort is made to ensure accuracy, translations may not always be perfect.

How to cite this ACE Report

OrthoEvidence. No difference in rate of malalignment between PSI and conventional instruments in TKA. OE Journal. 2018;6(11):2. Available from: https://myorthoevidence.com/AceReport/Show/no-difference-in-rate-of-malalignment-between-psi-and-conventional-instruments-in-tka

Copy Citation
Please login to enable this feature

To access this feature, you must be logged into an active OrthoEvidence account. Please log in or create a FREE trial account.

Premium Member Feature

To access this feature, you must be logged into a premium OrthoEvidence account.

Share this ACE Report