ACE Report Cover
Muller vs. Virtec straight stem shape comparable for long-term radiological change in THR
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り

ARTHROPLASTY

Similar effect of stem geometry on radiological changes with 2 types of cemented straight stem

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2016;4(12):16 Acta Orthop. 2016 Apr;87(2):120-5.

646 patients (711 hips) patients undergoing primary total hip replacement with straight femoral stem cement fixation were randomized to receive either a Muller straight stem (MSS) or the Virtec straight stem (VSS) for the purpose of comparing long-term radiographical and survival success ten years post-surgery. Results demonstrated that patients in both groups had comparable implant survival, osteolysis, subsidence, and debonding rates at 10 years.


出版資金提供の詳細 +
資金提供:
Not Reported
コンフリクト:
None disclosed

バイアスのリスク

4/10

報告基準

15/20

脆弱性指数

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

はい = 1

不確実=0.5

無関係 = 0

いいえ = 0

報告基準評価では、著者が出版物内で試験の方法論的特徴や試験特性を報告する際の透明性を評価します。評価は以下の5つのカテゴリーに分類されます。

2/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

2/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Fragility Indexは、重要な所見の解釈を助けるツールで、結果の強さの尺度を提供します。Fragility Indexは、その所見が有意でなくなるために、二項対立の結果に追加する必要がある連続した事象の数を表します。数値が小さいほど弱い所見を表し、数値が大きいほど強い所見を表します。

なぜ今この研究が必要なのですか?

There are two major femoral stem fixation methods that are regularly used in total hip replacement: shape-closed or force-closed stems. In shape-closed fixation, stems are surrounded by a thin cement mantle and are enhanced with an additional press-fit fixation against the cortical bone. Furthermore, shape-closed fixation can use varying stem shapes, including the Muller straight stem (which has a rectangular cross section) and the Virtec straight stem (which has a wider cross section with rounder edges). Due to the lack of conclusive evidence supporting a significant long-term benefit of one stem shape over the other, the current study was conducted.

主な研究課題は何ですか?

For patients undergoing cemented shape-closed fixation during total hip replacement, did either the Muller straight stem (MSS) or the Virtec straight stem (VSS) result in significant radiographical improvement in osteolysis, radiolucency, and distal migration when compared at least ten years post-surgery?

研究の特徴 +
人口:
646 patients (711 hips) patients undergoing primary total hip replacement with straight stem cement fixation were included in this study between July 1996 and July 2003. All surgeries were performed with a standardized lateral transgluteal approach while patients were in the supine position.
介入:
VSS group: patients received a Virtec straight stem, which is noted to have an oval cross-section and is wider in the sagittal plane, thereby allowing for a fuller filling of the femoral canal (n=355 hips; mean age=69+/-11, 217M/138F).
比較:
MSS group: patients received the Muller straight stem, which is noted to have a rectangular cross-section and longitudinal grooves running anteriorly and posteriorly and a small proximal collar (n=356 hips; mean age= 69+/-10, 202M/154F).
アウトカム:
Outcomes included radiographs assessing osteolysis, subsidence, and debonding. Osteolysis was defined as progressive, newly developed endosteal bone loss with a diameter > 3 mm with either a "scalloping" or a "bead-shaped" lucency at the cement-bone interface. Subsidence was assessed by measuring increases in radiolucency as a result of distal migration in the prosthetic shoulder from overlapping proximal cement in Gruen zone 1 (labelled as abnormal if the increase was greater than 2 mm). Stems were considered loose if circumferential osteolysis or radiolucencies were visible in any Gruen zone, or if subsidence exceeded 10 mm.
方法:
RCT: prospective, single-centre
時間:
Outcomes of interest were evaluated at 4 months, 1 year, 2 years, 5 years, and every 5 years thereafter.

重要な知見は?

  • When compared at 10 years, Kaplan-Meier (KM) survival after "revision of component for any reason" was observed to be 92% (95% CI 88-95) in the MSS group and 95% (95% CI 92-97) in the VSS group; the difference was not significant (p=0.1)
  • KM survival after revision for "aseptic loosening of the stem", specifically was 96% (95% CK 94-99) in the MSS group and 98% (95% CI 97-100) in the VSS group; the difference was also not significant (p=0.2).
  • 399 hips (196 in the MSS group and 203 in the VSS group) were radiologically assessed at a mean follow-up of 11 (10 to 16) years for unrevised hips and 6.85 (1 to 16) years for revised hips.
  • In the stems that were revised for aseptic loosening (n=22), 17 of them displayed radiological osteolysis on the final radiograph before revision; osteolysis was found to be more common in the MSS groups in Gruen zones 2, 6, and 7 (p=0.06, p=0.07, and p=0.04 respectively).
  • Subsidence was found in 5 MSS stems and 4 VSS stems; debonding at the cement-prosthesis interface was found in 6 MSS stems and 4 VSS stems (all 10 cases of debonding were observed in Gruen zone 1).
最も覚えておくべきことは?

For patients undergoing cemented shape-closed fixation during total hip replacement, both the Muller straight stem (MSS) and the Virtec straight stem (VSS) resulted in adequate long-term survival with minimal aseptic loosening, incidence of osteolysis, subsidence and debonding.

それが私の患者ケアにどのように影響するか?

The results of this study suggest that Muller and Virtec stems offer excellent survival over a 10 year period. Further randomized trials should be undertaken to evaluate the effect of stem geometry on radiographic changes and survival in different implants.

免責事項

このページに記載されている内容は、情報提供のみを目的としたものであり、専門的な医療アドバイス、診断、治療の代わりとなるものではありません。治療が必要な場合は、必ず医師の診断を仰ぐか、最寄りの救急外来を受診してください。このページに記載されている内容に関して個人が表明した意見、信念、見解は、OrthoEvidenceの意見、信念、見解を反映するものではありません。

0の4 月間無料記事のロック解除
今月の無料記事閲覧数が4件に達しました。

週1.99ドルからOrthoEvidenceにアクセスできます。

最新のエビデンスにアクセスしてください。いつでもキャンセルできます。
  • 整形外科における最新のインパクトのあるランダム化比較試験とシステマティックレビューの批判的評価
  • Journal of Bone and Joint Surgeryとのコラボレーション、国際的に著名な外科医へのインタビュー、整形外科ニュースやトピックに関する座談会など、OrthoEvidenceポッドキャストコンテンツへのアクセス
  • 週2回発行されるエビデンスに基づくニュースレター、The Pulseの購読。
Upgrade
Close Dialog
おかえりなさい
パスワードをお忘れですか?
今すぐ無料トライアルを開始

あなたのアカウントは
OrthoEvidenceへの無料アクセスが含まれます。


または
パスワードをお忘れですか?

または
Eメールをご確認ください

入力されたメールアドレスにアカウントが存在する場合、パスワードリセットのメールが送信されます。メールが届かない場合は、迷惑メールフォルダをご確認ください。

その他のサポート サポートチームまでご連絡ください。.

この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

ACEレポートを翻訳

OrthoEvidenceは、多言語でコンテンツにアクセスできるようにするため、第三者の翻訳サービスを利用しています。正確性を確保するためにあらゆる努力をしていますが、翻訳が必ずしも完璧ではない可能性があることにご注意ください。

引用方法 ACE Report

OrthoEvidence. Muller vs. Virtec straight stem shape comparable for long-term radiological change in THR. OE Journal. 2016;4(12):16. Available from: https://myorthoevidence.com/AceReport/Show/muller-vs-virtec-straight-stem-shape-comparable-for-long-term-radiological-change-in-thr

引用のコピー
この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

プレミアム会員機能

この機能にアクセスするには、OrthoEvidenceのプレミアムアカウントにログインする必要があります。

共有 ACE Report